HomeMy WebLinkAboutBuilding R7-15-0206
~
OJHKOfH
ON THE WATER
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLoshkosh.wLus
March 3,2006
Clark Meyer
Larson Meyer Architects LLC
5523 Integrity Way
Appleton, WI 54913
Richard Dworak
Dairy Queen
1325 TaflAve
Oshkosh, WI 54902
Site:
Dairy Queen
1325 TaflAve
Oshkosh WI 54902
For:
Description: Iuterior I Exterior Remodel
Object Type: Building only
Class of Construction: VB - 6000 Sq Ft.;
Occupancy: A-2: Assembly
Maxinrom No of Occupants: 82
Plan Number: R7-15-0206
Unsprinklered
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) I Conditions:
ANSI 303.4 Changes in level greater than y, inch shall be ramped in compliance with Section 405 or 406.
Verify that entrance I exits meet accessibility requirements.
.
716.2.2 Concealed wall spaces. Fireblocking shall be provided in concealed spaces of stud walls and
partitions, including furred spaces, at the ceiling and floor levels and at 10-foot (3048 mm) intervals both
vertical and horizontal. It would appear that fireblocking will be needed in Section 2 A 200.1.
mc 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
IBC 1003.2.2.5 Posting of occupant load. Every room or space that is an assembly occupancy shall have
the occupant load of the room or space posted in a conspicuous place, near the main exit access doorway
from the room or space. Posted signs shall meet the requirement of municipal code section 13-5. Min 12
inches in length, min 4 inches in height with min Y, inch lettering and the numbers being minimum 3
inches in height. The sign shall state "Limit (number) Persons".
mc 1003.2.10 Exit signs are required to be installed per this section
\\OSI IKOSIIM.ISfS..USERSobri.,m\2006 C",nm Plan Revie,,\R7-15-0106
Page 1 on
IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
are required to have adequate emergency lighting to meet the performance requirements ofIBC
1003.2.11.3. Existing means of egress emergency lighting is permitted to be maintained in compliance
with the code in effect at the time of construction. Any altered path of egress, or new path of egress,
and any new emergency lighting being installed is required to comply with current code requirements.
IBC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6
inches up onto walls.
COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least
one of each type provided shall be accessible.
Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting
plans and calculations shall be prepared in compliance with the code. The plans shall be available upon
request.
Comm 61.30(3) I IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC
equipment.
Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authòrized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm61.3I(l).
MUN 30 This review does not include review for signage. Applications for and questions regarding
signage permits should be directed to David Buck - Associate Planner (920) 236-5062.
MUN 30 This review does not include review for parking & zoning requirements Applications for
and questions regarding zoning review should be directed to David Buck - Associate Planner (920) 236-
5062.
SUBMIT:
.
Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. AII pennits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inqniries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
~/.
~~
Building Systems Consultant
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 AM and 12:30 AM to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required
Fee Received
Balance Due
$
$
$
320.00
320.00
0.00
,..oSJlKOSJlMISFS'I.JSERS..b,iann\2006 Comm Plan Hev;ew\R7.1.5-0106 1825 TafÌ Av< BJdg Only. doe