HomeMy WebLinkAbout0118329-Building
0
OSHKOSH
ON THE WATER
Job Address 2767 MINERVA ST
CITY OF OSHKOSH
No
118329
BUILDING PERMIT - APPLICATION AND RECORD
Owner DEWEY HOMES
Create Date
02124/2006
Designer
Contractor
DEWEY HOMES INC
Type
110 - New Single Family
Category
Plan 009-0206
. Building
0 Sign
0 Canopy 0 Fence Q Raze
Class of Const: ~
Rooms ~ Height 20 Ft.
Bedrooms ~ Stories Quad-level
Baths ~
Zoning
R-2
Size iRRG
Unfinished/Basement
~sq.Ft.
~sq.Ft.
0 Projection I
Finished/Living
Garage
~sq.Ft.
Canopies ---.2
Signs
---.2
Foundation
. Poured Concrete 0 Floating Siab
0 Concrete Block 0 Post
0 Pier
0 Treated Wood
0 Other
Occupancy Permit Required
Required
Flood Plain ~
# Dwelling Units ---.1
Height Permit Not Required
Park Dedication
# Structures
---.1
Use/Nature NSFRI New single family quad level with 2 car attached garage and 14' x14' patio. Driveway shall not exceed 24' wide at the front
of Work property line.
HVAC Contractor
AMERICAN HEATING & A C CO
CUMINGS ELECTRIC INC
Plumbing Contractor
Electric Contractor
P&S PLUMBING
Fees: Valuatio
$100,500.00 Plan Approval
$75.00 Permit Fee Paid
$412.00 Park Dedication
Issued By:
$200.00
Date~
Final/O.P. 00/00/0000
0 Permit Voided I
Parcelld # 1230130000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit appiicant to contact the easement
hoider(s) and to ~ nY.lJI'cessary approvals bef~re starting such activity.
signature/// r t---
/'~
Address 1941 BEECH ST
Agent/Owner
OSHKOSH
Date3-/-c~
WI 54901 - 0000
Telephone Number
920-231-3389
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
~
OSHKOSH
ON THE WATER
GRADE STAKE FORM
Grade Stake Number
7330
Name DEWEY HOMES
Address 2767 MINERVA ST
Create Date 02124/2006
Lot
113
Block
Ward
Subdivision 2nd add't Rusch & Kienast
Zone
I I Sidewalk Existing
Street Number
Lot Dimensions
Building Grade Elevation Stakes Set At. Site
02/27/2006
Set By
D.W.G.
BK-607, P-29
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the
has commenced.
Wisconsin Department of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
WISCONSIN UNIFORM
BUILDING PERMIT
APPLICATION
Appiication No.
0118329
Parcel No.
~ Constr
Plbg LiclCert #
250178
Plbg LiclCert#
170792
Plbg LiclCert#
6356
LiclCert #
0 HVAC 0 Elec
Mailing Address
1941 BEECH ST
Mailing Address
1941 BEECH ST
Mailing Address
PO BOX 749
Mailing Address
1129 MICHIGAN AVE
Mailing Address
PO BOX 2153
S . ft. 1/4,
Subdivision Name
2nd add't Rusch & Kienast
Front
0 Plbg
~ Erosion
0 Other:
OSHKOSH
WI 54902
Telephone No.
WI 54901 - 0000
Telephone No.
920-231-3389
Telephone No.
WI 54957 - 749 920-231-5946
Telephone No.
235-8090
Telephone No.
WI54912 - 2153 920-722-5035,9
WI 54901 - 0
Oshkosh
OSHKOSH
NEENAH
-0
Lot Area
APPLETON
Building Address
2767 MINERVA ST
Zoning District(s)
.T
N,R E(or)W
Block No.
Right
Solid Sola
0 Other:
0
0
Unfinished
Basement ~
Living Area 1716
Garage 609
22824 BTU/HR
14088 BTUIHR
$120.000.00
is permit is iss d p uant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS revocation of this pe it or other penalty
SEE "STANDARD CONDITIONS OF APPRO L" SHEET
Inspection
Wis. Permit Seal
Other
Total
SBD-5823 (R 07192)
$30.00
.,¡' Construction
HVAC
Electrical
0 Plumbing
0 Erosion
0
Date
2/24/06
$105.00
352343
Cert. No.
70330
0
OSHKOSH
ON THE WATER
Job Address
PARKLAND DEDICATION FEE COLLECTION RECORD
2767 MINERVA ST
Date 03/01/2006
Name
DEWEY HOMES
1941 BEECH ST
Oshkosh
~
~
Address
Subdivision 2nd add't Rusch & Kienast
Lot 113
Building Permit Number
Number of Dwelling Units
0118329
Number of Structures
- ,",.'- """' ~
Owner's Signature ~
Inspector's Signature
Date
Date
4.
5.
6.
7.
8.
9.
CITY' OY(fSm{lrSlI---'~---'-'----'--'-'-'-'---"
STANDARD CONDITI(jNS' 6î<'APPRlJVÃt'd'~,~ " " ,."
Project Address
27b7
H/N~VA
5.7"
,_Permit #
Please read the following information and sign at the bottom to acknowlêdgefhâfyouhãvéféâ:d
and agree to comply with these conditions.
1.
All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below grOlmdlevel mustbe provided with egress Wllldows
in addition to the Iight and ventilation requirements. Basement windows. are also
required to have window well areas in accordance with ILHR 21.03.
2.
Garage spaces shall be separated :&om the dwelling unit in accordance with ILHR 21.08.
The door and :&ame asS'embly between the dwelling unit and an attached garage shall be
labeled by âiiiíideiJendenttest1IÍg agency às having a minimUll:ifII"e-resistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness ( lI20-inch) and backed by solid wood or
drywall with the joints staggered.
3.
All penetrations in exterior walls mustbe sealed prior to the insulation inspection. This
includes holes hi the top âiid bottom plates, gaps around heating ducts, and holes in the
return air spaces.
Smoke detectors are required on every floor and within 6'ofall bediooms. Thesmõké '
detectors are required to be hardwiredâiid iiltèrcõl1rieded. ,,~. ..' .. .'
Hydromassage túbs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
Truss plans including the truss layout must be provided on site at the rough bUilding
inspection. In addition to ihétñissplâiis,míCiõlam ca1c1l1atioÍ1s111t1S!Þ~ provided on site
at the rough building illspeciiõIÍfõi all microíams WifhpôiñfIôads anthem.
Calculations must be provided for all cantilevered floors with point loads. Fíõoi-tñisses
and TJI'smust bé designed for ihécâll1:i1eveî:ëaã.í-êâs~" .-~~
10. The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2 " -3" diameter stone is
required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion
control measures must be maintained until the lawn is established.
11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12. The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13. All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re- inspection fee will be charged.
14. Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re- inspection fee per inspection.
15. When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16. The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.
Si m ature o j L pp /c. �� / /�� � .2)ate:
E~
~O,",se
q'
~""f"'~JI..
i.(!¡
~/ II;
1'-\ '1- ILl
. ?o,tio
'in
I\
'Si t .Ç'"",c.h
27(.7
/'v1/NIE/<.VA ST.
zz'
(Ll.!1' 113)