Loading...
HomeMy WebLinkAbout2006-Electric ~ OSHKOSH ON THE WATER Job Address 3001 S WASHBURN ST CITY OF OSHKOSH No 118286 ELECTRIC PERMIT - APPLICATION AND RECORD Owner FIRST HORIZON GROUP LIMITED PTNSHI Create Date 02/20/2006 Contractor ROYAL ELECTRIC INC 0 Change Category 643 - Commercial-Addition/Remodels Plan Service . New Volts 120/208 Amps ~ Circuits Type 52 0 Overhead . Underground 0 Temp 0 NIA Fixtures ~ Switches 20 Receptacles --~ Appliances l UselNature of Suite A60 Oshkosh B Gosh I Interior alterations per plans Work Fees: Valuation $31,390.00 Plan Approval $0.00 Penmit Fee Paid $280.00 Issued By: Date 02/23/2006 D Permit Voided I Parcelld # 1329420000 In the performance of this work i agree to perform all work pursuant to rules govemlng the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which It is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the penmit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address 640 MOASIS DR AgenUOwner LITTLE CHUTE WI 64140 -0 Telephone Number 920-788-8800 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue ifthe inspection is not performed within two business days from the time the project is ready. Electric Permit Work Card Job Address 3001 S WASHBURN ST Permit Number 118286 Create Date 02/20/2006 Owner FIRST HORIZON GROUP LIMITED PTNSHP Contractor ROYAL ELECTRIC INC Category 643 - Commercial-Addition/Remodeis Service b New Volts 120/208 Amps 300 0 ChangeO Temp ON/A I Type 0 Overhead Circuits 52 Switches 20 . Underground 0 NIA Fixtures 0 Receptacles 25 $31,390.00 Fee $280.00 D Value ~~m.. .... Appliances UselNature of Work Suite A60 Oshkosh B Gosh I Interior alterations per plans Inspections: Type Service Inspector Kevin Benner ---- not approved Date 03/29/2006 Not Ready: The new conductors need to be installed and the temporary wiring shall be removed from the raceway which the new conductors are to be installed. DatelTime requested: 03/28/2006 ~OO PM -- Notice Type: Access: Phone Number: Ready DatelTime: 03/28/2006 03:00 PM Requested by: -- 0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid ROYAL ELECTRIC INC Howard approved w/cond. i I The circuit breaker that is installed is a 400A current adjustable Sq.D "STR" model unit. This C.B. settings are! as follows: #1 .9, #2 .85 whick equals a 306 Amp setting. These settings were noted on the. WPS workcard which I noted, signed and ieft with Howard & Roger the electricians on site. Type Service Inspector Kevin Benner Date 03/30/2006 DatelTime requested: 03/29/2006 12:51 PM -- Notice Type: Access: Meet Howard on site Phone Number: Ready DatelTime: 03/30/2006 09:45 AM Requested by: -- 0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid ROYAL ELECTRIC INC