Loading...
HomeMy WebLinkAboutProperty Maintenance - 2/4/1994 "~ ^ OCCUPANCY INSPECTED ADDRESS CODE ENFORCEMENT DLVtSLON DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN VIOLATION/CORRECTION NOTICE e:e:: DATE INSPECTED FEBRUARY 4, 1994 APARTMENT BUILDING 666 JEFFERSON STREET #1 THOMAS SCHIESSL 54 BARTON ROAD, OSHKOSH, WI., 54904 MIULED FOLLOWING INSPECTION 80R GENERAL RELIEF DEPARTMENT OF SOCIAL SERVICES PLUMBING INSPECTOR OWNERS NAME ADDRESS NOTtCE DELIVERED/EXPLAtNED TO: ITEM IF 1. 2. 3. 4. 5. 6. 7. 8. ORDER 16-33A (7) 16-33A (9) 16-35.A (3) 16-35A (3) 16-34A (3) 16-34A (2) 16-33.1\ (2) 16-34A (3) 9. I LHR53. 63 COMPLIANCE DATE: FINDtNGS OF INSPECTtON THE BATTERY IS DEAD IN THE SMOKE DETECTOR. THE SMOKE DETECTOR SHALL BE PROPERLY REINSTALLED WITH A NEW BATTERY. THE DEADBOLT LOCKING DEVICE ON THE FRONT ENTRY DOOR SHALL BE REPAIRED OR REPLACED. THE TWO OPEN SEWERS IN THE BASEMENT WHICH WERE SHOWN TO YOU SHALL BE PROPERLY SEALED. ALL CPVG INSTALLED IN THE BASEMENT SHALL BE REPLACED WHERE IMPROPERLY INSTALLED. PLUMBER REQUIRED. A GFI ELECTRICAL WALL RECEPTACLE SHALL BE INSTALLED IN THE BATHROOM, PERMIT AND ELECTRICIAN REQUIRED. MECHANICAL VENTILATION IS REQUIRED IN THE BATHROOM. PERMIT & ELECTRI- CIAN REQUIRED. A LAVATORY SINK SHALL BE INSTALLED IN THE BATHROOM. PERMIT & PLUMBER REQUIRED. A SWITCHED LIGHT FIXTURE SHALL BE INSTALLED IN THE BATHROOM. ALL OTHER CEILING FIXTURES SHOULD BE EQUIPPED WITH SWITCHES TO PREVENT FIXTURES FROM BEING PULLED DOWN. ELECTRICIAN REQUIRED. THE OLD COLD AIR DUCT FROM THE BASEMENT TO SECOND FLOOR SHALL BE SEALED TO PREVENT FIRE SPREAD. DEF!C!ENC!ES MUST BE CORRECTED AND APPROV CONCEAlMENT. CALL (414) 236-5050 FOR I, P I f"MED lATELY !NSPECTOR: J OCCUPANCY INSPECTED ADDRESS CODE ENFORCEMENT D LVIS ION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN VIOLATION/CORRECTION NOTICE DArE !NSPECTED FEBRUARY 4, 1994 APARTMENT BUILDING 666 JEFFERSON STREET THOMAS SCHIESSL OWNERS NAME ADDRESS NOTICE DELIVERED/EXPLAINED TO: ITEM II< ORDER 10. ILHR82,4Q - 11. 7-43 12, 20-81\ COMPLIANCE DATE: 0:0:: FINDINGS OF INSPECTION THE THREADED END ON THE WATER HEATER RELIEF VALVE SHALL BE REMOVED OR THE TUBE REPLACED. (DOWNTUBE) OUR RECORDS DO NOT INDICATE A PERMIT WAS OBTAINED FOR THE INSTALLATION OF THE SEALED COMBUSTION FURNACE. PLEASE CHECK YOUR RECORDS AS TO WHEN THE FURNACE WAS INSTALLED AND BY WHOM. OUR RECORDS DO NOT INDICATE A PERMIT WAS OBTAINED FOR THE INSTALLATION OF THE SEALED COMBUSTION WATERHEATER. PLEASE CHECK YOUR RECORDS AS TO WHEN THE WATERHEATER WAS INSTALLED AND BY WHOM. GENERAL RELIEF VOUCHERS WILL CONTINUE TO BE ISSUED AS LONG AS PROGRESS IS BEING MADE IN THE CORRECTION OF THE VIOLATIONS. PLEASE FORWARD TO THIS OFFICE A WRITTEN LETTER ON INTENT WITH TENTATIVE CORRECTION DATES. If"MEDIATELY INSPECTOR: