HomeMy WebLinkAbout02/11/94-Housing Violations CODE ENFORCEMENT DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN VIOLATION/CORRECTION NOTICE DAn: INSPECTED FEBRUARY 11, 1994 OCCUPANCY INSPECTED ADDRESS OWNERS NAME ADDRESS NOTICE DELIVERED/EXPLAINED TO: TWO FAMILY IJ.'iELLING 52OA CEAPE AVENUE JOSEPH F. KOELBL 3121 VINLAND STREET MAILED FOLLOWING GENERAL RELIEF INSPECTION ITEM iF ORDER I. 16-33A (6) (~'2. 16-33A (6) 3. 16-33A (9) 4. 16-34A (1) 5. 16-34A 3A 5. 16-34A 3A 7. 16-34A 3c .8. 9. 16-34A 3D 15-35A (1) ( COMPLIANCE DATE: cc: SOCIAL SERVICES/ELECTRICAL INSPECTOR PL~mING INSPECTOR FINDINGS OF INSPECTION THE LOOSE HANDRAIL ON THE FRONT ENTRY STEPS SHALL BE MADE SECURE. CODE COMPLIANT HANDRAILS SHALL BE INSTALLED ON THE REAR ENTRY STEPS. THE DOUBLE KEYED DEADBOLTS SHALL BE REPLACED WITH DEADBOLTS WITH A THUMBTURN ON ONE SIDE AND KEY ON THE OTHER. SAFETY HAZARD IN CASE OF FIRE. HEAT SOURCES SHALL BE PROVIDED FOR THE SECOND FLOOR BATHROOM AND BEDROOM TO MAINTAIN TEMPERATURES OF AT LEAST 57". A WALL TYPE ELECTRICAL RECEPTACLE SHALL BE INSTALLED IN THE BATHROOM. THE NATIONAL ELECTRIC CODE REQUIRES IT BE A GFI TYPE RECEPTA<l.E. THE BRANCtj CIRCUITS OF THE 30 AMP ELECTRICAL SERVICE ARE OVERFUSED \-IITH A La AND 50 AMP FUSE WHICH CREATES A FIRE HAZARD. ELECTRICAL SERVICE PANELS SHALL BE READILY ACCESSIBLE TO ALL OCCUPANTS IN A IJ.'iELLING WITHOUT PASSING THROUGH ANOTHER MLLING UNIT. 620 CEAPE HAS NO IMv1EDIATE ACCESS TO ELECTRICAL SERVICE PANEL WHICH IS LOCATED IN THE KITCHEN OF 5201\ CEAPE. EXTERIOR LIGHTING SHALL BE INSTALLED TO ILLUMINATE THE REAR ENTRY STEPS. THE FRONT DOOR JAMB IS BADLY SPLIT AFFECTING THE SECURITY OF THE LIVING UNIT. THE JAMB SHALL BE REPLACED IN ORDER FOR THE DEADBOLT TO LOCK PROPERLY. . DEFICIENCIES MUST BE CORRECTED AND APPRO CONCEAL~EN'!. CALL (414) Z36-S0S0 FOR I SP IMMEDIATELY INSPECTOR: HOUSING INSPECTOR <. .' ~ OCCUPANCY INSPECTED ADDRESS CODE ENFORCEMENT DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN VIOLATION/CORRECTION NOTICE DAn: INSPECTED FEBRUARY 11, 1994 TWO FAMILY )AjELLING film r.FAPF AVFNIIF OWNERS. NAME ADDRESS NOTICE DELIVERED/EXPLAINED TO: ITEM iF ORDER 10. 16- 35A (1) (1J. 16-35A (4) 12. NFPA 54 13. I LHR82. 41 COMPLIANCE DATE: cc: FINDINGS OF INSPECTION THE DAMAGED REAR PRIMARY ENTRY DOOR SHALL BE REPLACED FOR SECURITY. THE VENTING ON THE SPACE HEATER APPEARS TO HAVE A DOWNHILL SLOPE WHICH MAY EFFECT THE DRAFT TO ROOVE COMBUSTION PRODUCTS. THE VENT SHALL BE INSTALLED WITH AN UPHILL SLOPE FOR PROPER OPERATION. THE SUPPLY LINE FOR THE GAS STOVE APPEARS TO BE LEAKING UNDER THE COUNTER TO THE RIGHT OF THE STOVE AS WHEN THE CABINETS ARE OPENED AN ODOR OF GAS .IS PRESENT. THE TUB FAUCET IS A BELOW THE RIM TYPE WHICH CREATES A CROSS CONNECTION OF POTABLE WATER AND SEWAGE. THE TUB FAOCET SHALL BE REPLACED BY A LICENSED PLUMBER. PERMIT REQUIRED. VIOLATIONS #f¡ AND #11 SHALL BE CORRECTED ON OR BEFORE FEB. 22, 1994. VIOLATION #12 SHALL BE CORRECTED ON OR BEFORE FEB. 18, 1994. VIQt-ATIONS #3, #4, ff3 & #10' SHALL BE CORRECTED ON OR BEFORE I-1ARCH 15, 1~. VIOLATIONS #1, ff2, & #5 SHALL BE CORRECTED ON OR BEFORE APRIL 15, 1994. VIOLATIONS #7, #8 AND #13 SHALL BE CORRECTED ON OR BEFORE MAY 15, 1994. ALL REQUIRED PERMITS SHALL BE OBTAINED BY RESPECTI DEFICIENCIES MUST BE CORRECTED AND APPR ED CONCEALMENT. CALL (414) Z36-S0S0 FOR I SPE I Mfv1EDIATEL Y INSPECTOR: