HomeMy WebLinkAbout4/7/94 Building maintenance (downspouts) OCCUPANCY INSPECTED ADDRESS OWNERS NAME ADDRESS CODE ENFORC EMENT Dr V! S ION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN VIOLATION/CORRECTION NOTICE DATE INSPECTED APRIL 71 1994 TWO ,FAMILY DWELLING 132 "JEST 12TH AVENUE MICHAEL FRAHM 1:525 CONGRESS AVENUE MAILED FOLLOWING INSPECTION WITH MRS, FRAHM, NOTICE DELIVERED/EXPLAINED TO: ITEM iF ORDER 1. 18-79,lA 16-35A (l) 2, 18-79,lA 3, 16-33A (6) 4, 16-35A (3) 5, 16-35A (4) ,6. 16-33A (9) 7. r'JFPA 54 COMPLIANCE DATE: e:e:: F!NDINGS OF INSPECT!ON DAMAGE IS OCCURING TO THE FOUNDATION OF THE BUILDING ESPECIALLY UNDER THE DO\<JNSPOUT AREAS WHICH ARE MISSING OR RUSTED THROUGH. THE PAINT IN THESE AREAS IS ALSO BEING AFFECTED, DOWNSPOUTS IN GOOD CONDITION SHALL BE INSTALLED TO DIVERT WATER AWAY FROM THE FOUNDATION, THERE ARE SEVERAL LEAKS IN THE ROOF ALLOWING RAINWATER TO ENTER THE LIVING AREAS IN THE BUILDING AND CAUSE DAMAGE TO THE CEILINGS AND PORCH EAVES. STEPS SHALL BE TAKEN TO REPAIR THESE AREAS WHICH ARE LEAKING, THE AREAS WHERE THE PAINT HAS BEEN REMOVED BY WATER SHALL BE PROPERLY PRIMED AND PAINTED "-'HEN THE LEAKS ARE REPAIRED, THE LOOSE HANDRAILS ON THE FRONT STEPS SHALL BE MADE SECURE, HANDRAILS ARE REQUIRED ON THE TWO SETS OF STEPS (COt<'M)N AREA) AT THE REAR AND ON THE OPEN SIDE OF THE BASEMENT STEPS, THE OPEN SEWER CONDITION ON THE SOUTH SIDE OF THE BASEMENT SHALL BE CORRECTED, THE VENTING ON THE WATERHEATERS SHALL BE CORRECTED BY PROPERLY SLOPING THE THE VENTING ON THE EASI WATERHEATER AND INSTALLING AT LEAST A 4 1/2 II VENT WHERE THE TWO THREE (5") VENTS ENTER THE CHIMNEY, DEADBOLT LOCKING DEVICES ARE REQUIRED ON ALL EXTERIOR LIVING UNIT DOORS A CAP SHALL BE INSTALLED ON THE GASLINE IN THE SOUTHWEST CORNER OF THE BASEMENT, m-1EDIATELY INSPECTOR: CODE ENFORCEMENT DrVISION DE?ARTMENTOF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN VIOLATION/CORRECTION NOTICE DATE INSPECTED APRIL 7) 1994 OCCUPANCY INSPECTED ADDRESS TWO FAMILY DWELLING 152 WEST 12TH AVENUE FRAHM OWNERS NAME ADDRESS NOTICE DELIVERED/EXPLAINED TO: e:e:: HEM iF ORDER 8. 16-35A (3) " 9, 16-35A (3) F!NDINGS OF INSPECTION STEPS SHALL BE TAKEN TO BRING THE WATER PRESSURE IN THE BUILDING UP TO THE REQUIRED PRESSURE. DURING THE INSPECTION1 I FAILED TO CHECK FOR BACKFLO!'J PROTECTION ON THE Th'O BOILERS, IF THESE BOILERS ARE NOT EQUIPPED WITH BACKFLOW PROTECTION IT SHALL BE INSTALLED BY A LICENSED PLUMBER, CONTACT THE PLUMBING IN- SPECTION FOR rvDRE INFORMATION IF REQUIRED, VIOLATIONS tf31 #41 #5 & tf7 SHOULD BE CORRECTED AS SOON AS POSSIBLE AS THEY CREATE HAZARDS FOR THE TENANTS, PLEASE CONTACT THIS OFFICE IN WRITING AS TO THE TIME REQUIRED TO COR- RECT THE REMAINING VIOLATIONS WITH POSSIBLE DATES OF COMPLIANCE. THANKYOU FOR YOUR COOPERATION. COMPLIANCE DATE: IMMEDIATELY INSPECTOR: