Job Address 3001 S WASHBURN ST
CITY OF OSHKOSH
No
118245
BUILDING PERMIT -APPLICATION AND RECORD
Owner FIRST H.oRIZ.oN GR.oUP LIMITED PTNSHP
Create Date
02/09/2006
Designer
Courtland Morgan AlA
Contractor
BURDGE DUNHAM & ASS.oCIATES C.oRP
Category
232 - Alteration Stores & Customer Service
Plan R6,08-0206
Type
. Building
0 Sign
0 Canopy
0 Fence
0 Raze
Zoning
Class of Const: 2B
Size
Garage
~Sq.Ft.
Rooms 0 Height 0 Ft.
Bedrooms 0 Stories 1
Baths 0
D Projec~on I
Unfinished/Basement
~Sq.Ft.
~Sq.Ft.
Canopies 0
Finished/Living
Signs
0
Foundation
. Poured Concrete 0 Floating Slab
0 Concrete Block 0 Post
0 Pier
0 Treated Wood
0 .other
.occupancy Permit Required
Flood Plain No
Height Permit Not Required
Park Dedication
Not Required
# Dwelling Units ~
# Structures
0
Use/Nature .oshkosh B Gosh - A60 -Interior alterations as per plans.
of Work
HVAC Contractor
UNKN.oWN???
Plumbing Contractor
UNKN.oWN
Electric Contractor
R.oYAL ELECTRIC INC
Fees: Valuation $71,531.00 Plan Approval
Issued By: ~
$0.00 Permit Fee Paid
$280.00 Park Dedication
$0.00
Date 02121/2006
Final/O.P. 00/00/0000
D Permit Voided i
Parcelld # 1329420000
In the performance of this work I agree to perform all work pursuant to nules governing the described construction.
While the City of .oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
:~~~~::::n~~forestartingSUChactiVity. Date 2-2f-()¿
AgenUOwner
Address P.o 157
HAMILT.oN
M.o 64644 - 0000
Telephone Number
816-583-2123
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
~
OJHKOIH
City of .oshkosh
Division of Inspection Services
215 Church Avenue
P.o Box 1130
.oshkosh WI 54903-1130
www.ci.oshkosh.wi.us
0"'", WATER
February 15, 2006
Courtlan Morgan, AlA
Cortlan Morgan, Architect
6910 Woodland Drive
Dallas TIC 75225
Mark A Levy,PE
Levy Engineering Consultants
6515 East 82nd Street, Suite 206
Indianapolis IN 46250
James Dunham
Burdg, Dunham & Associates
920 S Hughes
Hamilton, MO 64644
Stefanie Cirrincione
Prime Retail
100 East Pratt Street
Baltimore MD 21202
Ms. Brenda Schalinske
Oshkosh, B'Gosh
112 Otter Ave
Oshkosh WI 54902
Site:
Oshkosh ß'Gosh
3001 S Washburn St
Oshkosh WI 54904
For:
Description: Tenant space alterations
Object Type: Building and HV AC
Class of Construction: 1m - 8010 Sq Ft.;
Occupancy: M: Mercantile / Retail
MaximwnNo of Occupants: 208
~r<"~ CoD
Plan Number: R6-08-0206
sprinkIered
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as deemed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) / Conditions:
.
mc 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping
system that matches the rating of the wall assembly being penetrated. Copies ofthefirestopping systems
are required to be provided at the time ofinspection.
712.1 Fire-Resistant Joint Systems General. Joints installed in or between fire-resistance- rated walls,
floor or floor/ceiling assemblies and roofs or roof/ceiling assemblies shall be protected by an approved fire-
resistant joint system designed to resist the passage of fire for a time period not less than the required fire-
resistance rating of the wall, floor or roof in or between which it is installed. Fire-resistant joint systems
shall be tested in accordance with Section 712.3. Provide copies of tested/listed head ofwallfirestop
detail- Detail 5A on sheet A5.2 does not include listed head of wall joint assembly number.
IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with
this code and the international fire code. (Construction of new walls may require the addition and or
relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire
sprinklers)
mc 906.1 / IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
mc 1003.2.10 Exit signs are required to be installed per this section.
'.'.OS1 11<051 IMISFS\USFRS'.bri'Ðm'20ú6 CeTIen Plan Rev;",'.R6-08-0206 )(jO I \Veshbum 51 mdg & ¡ ¡VAC".d""
Pagelof4
mc 1004.3.2.1 Construction Corridors (the rear egress path through the "hallway" and "exit
Corridor" is considered a corridor.) shall be fire-resistance rated in accordance with Table 1004.3.2.1.
The corridor waHs required to be fire-resistance-rated shall comply with Section 708 for fire partitions.
Table 1004.3.2.1 Exception c. Buildings equipped throughout with an automatic sprinkler system
in accordance with Section 903.3.1.1 or 903.3.1.2. This will require the monitorinfi and alarms per
Section 903.4 this includes ALL valves controllinf! water suvvlv.
1004.3.2.4 Air movement in corridors. Corridors shaH not serve as supply, return, exhaust, relief or
ventilation air ducts or plenums.
Exceptions:
2. Use of the space between the corridor ceiling and the floor or roof structure above as a return air
plenum is permitted for one or more of the foHowing conditions:
2.3. - The air-handling system serving the corridor is shut down upon activation ofthe air-handling unit
smoke detectors required by the International Mechanical Code. (Verijÿ that smoke detectors noted on
sheet MJ.O are installed and function as required, and shut down the HVAC equipment)
mc 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6
inches up onto walls.
mc 2406.2 Glazing in an individual fixed or operabje panel adjacent to a door where the nearest exposed
edge of the glazing is within a 24 inch arc of either vertical edge of the door in a closed position and where
the bottom exposed edge of the gjazing is less than 60 inches above the walking surface is requires safety
glazing materials. (Note 6 under General Accessibüity and Life Safety (Sheet Tl.1) states within 18
inches - the code requires within 24 inches of doors to be safety glass..)
COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least
one of each type provided shaH be accessible.
mc 1l01.2IANSI A1l7.1-308.2 & 3 - Mechanical system controls shaH be located a maximum of 48"
above the finished floor if the floor space all.ows a forward approach by a wheel chair or if the clear space
allows a paraHel approach.
IMC 302.1 The building or structure shall not be weakened by the iostallation of mechanical systems.
VerifY that existing structure is capable of supporting the additional weight of the proposed rooftop
equipment. The designer of record is responsible to verifY that loads have been transferred properly. If
upon inspection there is still a question, calculations may be required.
IMC 304.1 Equipment and appliances shaH be instaHed as required by the terms of their approval, in
accordance with the conditions of the listing, the manufacture's instructions and this code. Caution on
clearance requirements for unit heater in storage room.
IMC 401.5.1 Mechanical and gravity outside air intake openiogs shaH be located a minimum of 10 feet
from any hazardous or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys,
parking l.ots and loading docks.
IMC 405.1 Mechanical ventilation systems shaH be provided with manual or automatic controls that win
operate such systems whenever the spaces are occupied. Air conditioning systems that supply required
ventilation air shaH be provided with controls designed to automaticaHy maintain the required outdoor air
supply rate during occupancy.
602.2.1 Materials exposed within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.4,
materials exposed within plenums shaH be noncombustible or shall have a flame spread index of not more
than 25 and a smoke-developed index of not more than 50 when tested in accordance with ASTM E 84.
602.2.1.4 Combustible electrical equipment. Combustible electrical equipment exposed within a plenum
shaH have a peak rate of heat release not greater than 100 kilowatts, a peak optical density not greater than
0.50, and an average optical density not greater than 0.15 when tested in accordance with UL 2043.
Combustible electrical equipment shaH be listed and labeled. (Caution on speakers and components
located above ceiling)
\,.osIlKOSJ JMJSFS\USFRS\bri"m"200(i Comm Plan Rov;o,"\RÓ-O8-020c 300 I Woshhurn $, Blc!g & lTVA('c!oc
Page2of4
IMC 606.2.1 Smoke detectors shall be installed in return air systems with a design capacity greater than
2000 cfm IMC 606.4.1 The sm.oke detect.ors shall be connected to a fire alann system. The actuation of a
smoke detector shall activate a visible and audible supervisory signal at a constantly attended location.
IMC 606.4.1 Exception 2. In occupancies not required to 'be equipped with a fire alann system, actuation
of a smoke detector shall activate a visible and an audible signal in an approved location. Smoke detector
trouble conditions shall activate a visible or audible signal in an approved location and shall be identifies
as air duct detector trouble.
Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened
from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236-
5062 for additional information on screening requirements. All screening shall be properly anchored in
place to resist wind loads. Additionally!BC 1608.8 Roofprojections - Drift loads due to mechanical
equipment, penthouses, parapets and other projections above the roof shall be determined in accordance
with Section 7.8 of ASCE 7. (Screening will not be required for replacement unit of the same size and
location. New or relocated equipment will require a screening plan. Additionally there may be
screening requirements for the Satellite Mounting System shown on sheet E3.0.)
SUBMIT:
IFC 901.4 Fire protection systems shall be maintained in accordance with the original installation
standards for that system. Required fire protection systems shall be extended, altered, or augmented as
necessary to maintain and continue protection whenever the building is altered, remodeled or added to.
Alterations to fire protection systems shall be done in accordance with applicable standards. Submit plans
for fire sprinkler modifications.
. mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
through The Retail Display area are required to have adequate emergency lighting to meet the performance
requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan (Point to Point
Illumination plan) -showing compliance with these requirements prior to installation of emergency
lighting system. Additionally emergency illumination is required to be installed on the exterior side of
all new or relocated exit doors. It would appear based on the plan provided the emergency lighting in
the stock room will not meet the light level requirements.
IECC 503.3.3.7 [Comm 63.0503(2)(f)] Balancing and documentation ofthe HV AC system shall conform
to the !MC. Balancing report required to be submitted prior to final occupancy being allowed.
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
NFP A 72 4.5.2 Provide a copy of the fire alann system record or completion for the required monitoring
and alarms of the automatic fire sprinkler system
'OO!
Page3 of 4
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In grantiog this approval the City of Oshkosh Inspection Services Departroent reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
Respec~
~
Building Systems Inspector.
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 AM and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
800.00
800.00
0.00
'.'.OSI IKOSHM¡SFS'.USERS'.bTI""n'2006 Comm ¡>1¡;n Revìe,,'.R6-08-020Ô 3()(\ I Wa,hbuTI1 51 Bldg & ¡¡VACdoe