HomeMy WebLinkAbout0118227-Building
e
OSHKOSH
ON THE WATER
Job Address 2020 MENOMINEE DR
CITY OF OSHKOSH
No
118227
BUILDING PERMIT -APPLICATION AND RECORD
Owner
Create Date
02/0212006
Designer
Contractor
LEACH BROS.
Category
110 - New Single Family
Plan 006-0106
Type
. Building
0 Sign
0 Canopy
0 Fence
0 Raze
Zoning
R-1
Class of Const: 8
Size irrg
Unfinished/Basement
2395 Sq. Ft.
4927 Sq. Ft.
Rooms g Height 32 Ft.
Bedrooms 3 Stories 2
Baths 3
0 Projection I
Canopies ----.Q
Finished/Living
Garage
~Sq.Ft.
Signs
0
Foundation
. Poured Concrete 0 Floating Slab
0 Concrete Block 0 Post
0 Pier
0 Treated Wood
0 Other
Occupancy Penmit Required
Flood Plain No
Height Permit Not Required
Park Dedication
Required
# Dwelling Units 1
# Structures
Use/Nature NSFRI New single family 2 story with 3 car attached garage, 12' x 13' screen porch, 15' x 24' concrete patio, 10' x 55' concrete patio and
of Work paved driveway.
HVAC Contractor
E C MERRILL INC
Plumbing Contractor
O'NEILL ENTERPRISE INC
Electric Contractor
UNKNOWN????
Fees: Valuation
Issued By: ~
$580,000.00 Plan Approval
$75.00 Permit Fee Paid
$1,834.00 Park Dedication
$200.00
Date 02117/2006
Final/O.P. 00/00/0000
0 Permit Voided I
Parcelld # 151188000
In the performance of this work I agree to perform all work pursuant to nules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) an~..~~.~ecure ~ny necessary ~vals before stariing such activity.
Signature,.." . d - '-~
L.," AgenUOwner
Address 2883 RUSCHFIELD DR Oshkosh
Dat~//YO6
WI 54904 - 0000
Telephone Number
420-5005
To schedule inspections' please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
Wisconsin Department of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
WISCONSIN UNIFORM
BUILDING PERMIT
APPLICATION
Application No.
0118227
Parcel No.
E:J Constr
Plbg LiclCert#
964647
Plbg LiclCert#
985566
Plbg LiclCert#
3898
LiclCert #
225344
0 HVAC 0 Elec
Mailing Address
2020 MENOMINEE DR
Mailing Address
2883 RUSCHFIELD DR
Mailing Address
0 Plbg
E:J Erosion
0 Othec
OWne~s Name
Oshkosh
Telephone No.
WI 54901 - 0000
Telephone No.
420-5005
Telephone No.
Oshkosh
WI 54904 - 0
-0
Mailing Address
1018 W SOUTH PARK AVE
Mailing Address
522 W 6TH AVE
Lot Area
S . ft.
Subdivision Name
1/4,
Telephone No.
(920) 235-3600
Telephone No.
OSHKOSH WI54902 -0 920-230-2007
1/4,Section ,T N,R E(or)W
Lot No. Block No.
OSHKOSH
WI 54902
-0
Rear
Left
Right
New
0 Alteration
0 Addition
0 Repair
0 Raze
0 Move
orced Air Furnace
0 Radiant Baseboard or Panel
0 Heat Pump
E:J Boiler
Central Air Conditioning
Other
Nat loP. Oil Elec. Solid Sola
Ga
SpaceHtg E:J 0 0 0 0 0
Water Htg E:J 0 0 0 0 0
Dwelling unit will have 3 kilowatt or
more install",! electric space heating equip.
Infiltration control option is: E:J Full sealing
of joints. 0 Blower door test 0 Exterior
air infiltration barrier.
Fuel
0 Other:
Living Area
Garage
96109 BTU/HR
52835 BTUIHR
$900,000.00
APPLICANT'S SIGNATU
APPROVAL CONDITIONS This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
revocation of thiS permit or other penalty
SEE "STANDARD CONDITIONS OF APPROVAL" SHEET
Inspection
Wis. Permit Seal
Other
,¡' Construction
HVAC
Electrical
Plumbing
0 Erosion
0
Date
2/2/06
Totai
SBD-5823 (R. 07/92)
$105,00
352247
Ceri. No.
70330
e
OSHKOSH
ON THE WATER
PARKLAND DEDICATION FEE COLLECTION RECORD
Job Address
2020 MENOMINEE DR
Date 02/17/2006
Name
Address
2020 MENOMINEE DR
OShkosh
'!'!L
~
Subdivision
Lot
Building Permit Number
Number of Dwelling Units
0118227
Number of Structures
Fee Required
$200.00
Fee Paid
Owner's Signature
;)¿12~ ~
Date ~7 /oc
Inspector's Signature
Date
6.
7.
8.
9.
CITY1>1fð"BßKðลกïi 7"'~" "
STANDARD CONDITlONS-ÖF"ÄPPRtJVA't"" I' ',-"~.~._'.c,-_,c..~--,..~
Project Address
Me/lom!jnep
Zo~ò
1>1<
Permit
Please read the following ìnformation and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
I.
All habitable rooms must be provìded with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level mustþe provided with egress windows
in addìtion to the lìgIítãiiirvêïiiIìãÜonrequiremeiits. ' B~ement windows are also
required to have window well areas in accordance with ILHR 21.03'. ".. .
2.
Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minìmum fue-resistive rating of 20
minutes. All drywall joints are requìred to be taped/sealed unless the joìnts are fitted so
that the gap is no more than a dimes thickness ( lI20-inch) and backed by solid wood or
drywall with the joints staggered.
3.
All penetrations in exterior walls must be sealed prior to the insulation inspection. Tills
includes holes in the top and bottom plates, gaps around heating ducts, and hole,sjl1 the
return air spaces.
4.
Smoke detectors are required on every floor and within 6' of all bêdioollls: T!Îê smoke
detectors are required to be hardwired and interconnected.
5.
Hydromassage tubs are required to"havê an access panel to motor. The access panel must
be accessible without removìng the finish of the house.
i
i
I
~
All overframing must be designed by the truss manufacturer, according to standards set
by the truss prate instiiu.Ù:, or structural calculations must be provìded prior to the rough
buìlding inspection.
Truss plans must be submitted arid approved prior to framing the roof.
Truss plans including tIiê truss Ìa.yout must be provided on sifeat the rough buIlding
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for allmicrolams with point loads on them.
~.
Calculations must be provided for an cantileveredflogrs with ¡Joint loads. Floor trusses
and Tn's .IIitisfbe desigiiêd for the cantilevered areaS. .
10.
11.
12.
13.
14.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosìon Control). When installing access dr-iv~s, a minimum
required in addition toa miniIllum<Jf(j"depth, 30'-50' length, and
control measures must be maintained until the lawn is established.
""'c""""""""""(,""""'.ff""""44;,,;;.,!,,,,~;J;"~;'""Y!"'~"("~"¥"-~",,',,"'i!!("""'.",,,~,,,,,
All storm, s~wer in!~t~my~tþ'e protected with approved erosion, control device,s. Tracking
(i.e. sediment) must be removed from tlJe~treet at the end of e¡¡çhwgr!cday. Repair any
siltation or erosion dan1age to adjoining suriace;~d'dr,¥;;.ãg~w;Y~';:ésU11:íñgfi-oïñÌâiid
development or disturbing activities.
The building pl¡¡card must1:¡~ posted on site at all.tim~s,., Q!.!ç~ th~ rpugh fram.ing is up
the placard must be posted on the patio door or on a kitchen\Vindp\y, . Ifth~ placard is not
present¡¡t anY inspection, stop work orders will be posted. AdditÍ<mal placard~ Can b.e
obtaine4wgygh our department if th~, çards, !!Ie misplaced.
Alllll~chilJ)Iç.!tl§Æ,y§tÞ£l.°ughed in prior to requesting the rough building inspection. If
on the inspection themeçhanicals!!Ie ngtroughed in, the inspection will fail and a $100
re-inspection feewillbeçh!!Iged.
Attached isa.copy ofthe final inspection checklist. At thej:}!.!a.)in~pection all items on
this list llly§tþ'~çgmpleted to avoid the $100 re-inspection fee per inspection.
15.
When, requesting final inspections please note that aminimJ.1.Ill<Jf2.4ays notice is needed
from the tiIne thejnspection is ready. Furniture is only allowed to be placed in the center
ofthe garage floor and a minimum {)fa.3' pathway must be provided aro\llld tlJe \Valls of
the garage. At the [mal inspection no furniture or personal belongings are allowed intlJ~,.
hguse,¡\ppliances such as the, stove, n;frigerátor, washer, and dryer are not to be set in
place due tothee!~£tP.ç.al,,¡!!8pector needing to look at the power serving the appliances.
A 6' stepladder must be on ~it~ atthefin¡¡l inspection to provide access to the attic.
16.
The building placard m~tremainPIlthe patio door or on akitçhen\VÏIl9.pXY.,!!!:lÊ,L."""
occupancy is approved. . Occupancy is not allowed prior to the placard ha.ying all of the
final inspection approved stickers on tlJe ba.ckê¡cI~,;ILg.s,çupancy occurs prior to the
inspections being approved daily citations will be issued witlJng furth.erIl9!i5§J?,~~Bg
given.
..,....,..,... ;',"" "
All site grading must be done in accordance with the approved drainage plan on file in the
public wor!cs.offiçe, 3rd floor.
S<g-1~ "!-4~ ~" L
17.