HomeMy WebLinkAbout2006-Letter (HVAC plan review) ~ OJHZOJ1-j ON'"' WATER City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI549D3-1130 www.ci.oshkosh.wi.us January 30,2006 Paul Sobieck Milwaukee Stove & Furnace 2442 Hutson Road Green Bay WI 54303 Schwab Properties 601 Oregon St Oshkosh WI 54902 Site: Schwab Properties 601 Oregon St Oshkosh WI 54902 For: Description: Basement Office Object Type: HVAC only Class of Construction: VB - 823 Sq Ft.; Unsprinklered Occupancy: B: Business I Office Plan Nnmber: RS-O4-0106 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: IBC 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed flrestopping system that matches the rating of the wall assembly being penetrated. Copies of the flrestopping systems are required to be provided at the time of inspection. Based on review of property file it would appear that ductwork is penetrating rated walls - verify actualfield conditions, andfirestop properly iffirewalls are penetrated. IBC 1101.2/ANSI A117.1-308.2 & 3 - Mechanical system controls shall be located a maximum of 48" above the finished floor if the floor space allows a forward approach by a wheel chair or if the clear space allows a parallel approach. IMC 304.1 Equipment and appliances shall be installed as required by the terms of their approval, in accordance with the conditions of the listing, the manufactures instructions and this code. 403.2 Outdoor air required. The minimum ventilation rate of required outdoor air shall be determined in accordance with Section 403.3. No information as to volume of outside air provided by existing constant volume system was provided - Designer to verify that existing system provides adequate outside air to provide for this space that is being converted from previously unfinished storage space to an occupied area. IMC 403.3.4 Balancing Ventilation systems shall be balanced by an approved method. Such balancing shall verify that the ventilation system is capable of supplying the airflow rates required by Section 403. 1MC 405.1 Mechanical ventilation systems shall be provided with manual or automatic controls that will operate such systems whenever the spaces are occupied. Air conditioning systems that supply required ventilation air shall be provided with controls designed to automatically maintain the required outdoor air supply rate during occupancy. Page l.on IECC 803.3.3.3 Off-hour controls. Each zone shall be provided with thermostatic setback controls that are controlled by either an automatic time clock or programmable control system. Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm61.31(1). SUBMIT: . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the nmnber listed below or the address on this letterhead. ~ Building Systems Consultant (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 230.00 230.00 0.00 PhnReÙ,d(5-i14-\J[\J660! -': ¡¡VACOniy.d", Page 2 on