Loading...
HomeMy WebLinkAbout2005-EMAIL-CALLISON ARCHITECTURE Plan Review Application and Code LinksPage 1 of 2 Haedt, Chris A. From: Noe, Brian Sent: Thursday, December 15, 2005 10:59 AM To: Haedt, Chris A. Subject: Old Navy 3001 S Washburn FW: Q8-93-1005-Oshkosh, WI; Roof Plan   -----Original Message----- From: Ted Udhus [mailto:Ted.Udhus@callison.com] Sent: Tuesday, December 13, 2005 4:50 PM To: bnoe@ci.oshkosh.wi.us Cc: Kelsey Blommer; Tom.Rogers@multisiteinc.com Subject: FW: Q8-93-1005-Oshkosh, WI; Roof Plan  Brian I left you a voicemail Tuesday afternoon -    Would it be possible to reduce the one 16' length of screening to 15' max in order to avoid the drift   load requirement? This would pull the end of the wall farther from the 'toe' of the sloped roof and would not pose an aesthetic issue as it would not be possible to view the RTU unless you were on the roof.  Our engineers have confirmed that drift load calcs would be required if the wall was over 15' and any structural modifications may be significant.  Please see attached photos and sketch for clarification.    Please give me a call to discuss at your earliest convenience - thank you, Ted J. Udhus Associate ted.udhus@callison.com CALLISON ARCHITECTURE, INC. 1420FIFTH AVENUE #2400 SEATTLE, WASHINGTON 98101-2343 T 206 623 4646  F206 623 4625   From: Noe, Brian [mailto:bnoe@ci.oshkosh.wi.us] Sent: Wednesday, December 07, 2005 1:32 PM To: Kelsey Blommer Subject: RE: Q8-93-1005-Oshkosh, WI; Roof Plan Has this been evaluated for drift loading?  I believe anything greater than 15 feet in length is required to be evaluated for drift loading. -----Original Message----- From: Kelsey Blommer [mailto:Kelsey.Blommer@callison.com] Sent: Wednesday, December 07, 2005 12:50 PM To: Noe, Brian Cc: Ted Udhus; peter.donnellan@multisiteinc.com Subject: Q8-93-1005-Oshkosh, WI; Roof Plan Brian, Per our recent phone conversations and our conversation with David Buck, please see attached roof plan identifying the locations of RTU screening.  I've also attached a product brochure for your 1/31/2006 Plan Review Application and Code LinksPage 2 of 2 review. Please let me know if you need any additional information. Thanks for your help. Kelsey Blommer Associate kelsey.blommer@callison.com CALLISON ARCHITECTURE, INC. 1420 FIFTH AVENUE #2400 SEATTLE, WASHINGTON 98101-2343 T 206 623 4646  F 206 623 4625    _________________________________________________ This message is private or privileged. If you are not the person for whom this message is intended, please delete it, notify me immediately, and do not copy or send this message to anyone else. __________________________ This email has been scanned for all known viruses. _________________________________________________ This message is private or privileged. If you are not the person for whom this message is intended, please delete it, notify me immediately, and do not copy or send this message to anyone else. 1/31/2006 ~ PRE'MANl.fACTlMEO. LOUVEREO SCREENNG- TOP Df WALL 6" !IN. ABOVE RTU. COLOR TO MATCH EXISTNG METAL ROOFING ROOF TOP HVAC UNIT IRTUI. TYP. 14',0" TYP. ~ ~ cp ~ -- -- -; - ~- -- -- -- -- -~ -- - -- -- ---¡-------------- -- -- -- -- -~ -- -- -\- -- - - -- -- -- -- -¡- -- -- -- ----------------~-- -- -- -- -- -- -- -- -- -- - ~- -- -- -- Î- -- -- G . Iii i i I ¡Ii i i i ~!._--------- .j 1 1 1 1 1 1 r 1 1 1 , , APPROXIMATELY 112:12 SLOPE: ' , , 1 1 EXISTING MEIllRANE ROOFNG 1 1 1 1 1 1 1 1 ----_._~---_._------_W: I: ___+L______---:-----------~---------_.~._--~-- CD 1 1 1 1 1 1 1 1 1 1 1 1 i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i r i i i i LEASE LINE i i APPROXIMATELY 3:12 SLOPE; i i I' ~ , , , EXISTING METAL ROOFING , I' - - - . - . - 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 :/TLEASE LINE , , I 1 1 1 1 1 1 I: 1 , , , , , ,I, 1 1 1 1 1 I' 1 1 1 1 1 1 1 j 1 1 1 1 1 1 I; 1 1 1 1 1 1 1 1 , , , I 1 Iii i i i i i i i ¡¡I i 1 Iii ¡¡I i 1 Iii i i i , , , I 1 Iii i i i i i i i ¡¡I i i i i i ¡¡I i i i i 1 APPROXIMATELY 1):12 SLOPE; i i i i 'I ' , EXISTING METAL ROOFING, , ,I, 1 1 1 1 1 1 I' , , , , , , . 1 1 1 1 II! 1 - - - - - - - - - ~ -~ =- -- ---~.::. -=--~ i =- ~-....: = ----- =.::. ----~.::. -=- ---....: = ~-....: ~ -- --- =.::. ----~.::. =- ---....: = ~-~ = -- ----~~ ----~.::. =- ~-....: = ---~ = -- ----~.::. -=- ---....: ~ ~-'\- = -- --- =.::. ----~.::. =- ---....: = ~-~ =i-- ---~.::. -=--~.::. =- ~-....: = =--~ = -- ----~ .::.~-~....: =- ~-....: = -- --- =.::. -=.:L~.::. =- ---....: ~ =--....: = -- --- j - - - - - ø 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 F ACE OF WALL BELOW 1 1 1 , , , , , ---------~--~--------r-- 1 1 1 1 - '~ 1 '" b l¡ã 1;>", ;..,d 3',0" CLR. TYP. a: ~ 9 i:2 L. L. L. L. L L. (1) N NEW STORE @[1[Q) œÆW @(ill1Y[1Œ1Y GAP INC. CORPORATE ARCHITECTURE 901 CHERRY AVENUE SAN BRUNO, CA 94066 (650) 952-4400 STORE NO.: 1734 GAP PROJ. 1.0.: 0000038701 VERSION: REVISION: OS/27/05 Û DO ISSUE: 08/11/05 CHECKSET: 09/16/05 CD ISSUE: 09/28/05 CONSUL TANT: STAMP: ARCHITECT: u z Z - ~ ,¡ '" 0 : ~ - IJ) g~~ - "¡;:c ...I i. 2 E .. ~ ~"'"' ~ ...I ". -.. '" . C;:~~~~ « ~~~~~~ to - -'" "'. u :¡~Ë:g:g ~ """"""0 ~;':.:;....o LOCA TlON: PRIME OUTLETS AT OSHKOSH .3001 S WASHBURN OSHKOSH, WI 54904 DATE: 09/28/05 ISSUED FOR: DA TE: PERMIT/BID/LL: 09/28/05 CONSTRUCTION: 09/28/05 SCALE: DRAWN BY: JOB NO.: AS NOTED KB 204313.33 SHEET TITLE: ROOF PLAN SHEET NUMBER: A3-1