Loading...
HomeMy WebLinkAbout0117627 B No117627 CITY OF OSHKOSH OSHKOSHBUILDING PERMIT - APPLICATION AND RECORD ON THE WATER OSHKOSH OFFICE BUILDING LLC Job Address2990-2998 UNIVERSAL STOwnerCreate Date12/19/2005 DesignerContractorAHERN FIRE PROTECTION Category223 - Alteration Offices, Banks, ProfessionalPlanQ2-70-0805 TypeBuildingSignCanopyFenceRaze ZoningClass of Const:Size Sq. Ft.Projection Unfinished/Basement0Rooms0Height0Ft. Finished/Living 0Sq. Ft.Bedrooms0StoriesCanopies0 Garage0Sq. Ft.Baths0Signs0 Poured ConcreteFloating SlabPierOther Foundation Concrete BlockPostTreated Wood Occupancy PermitFlood PlainHeight Permit Park Dedication# Dwelling Units0# Structures0 Office/ Installation of Automatic Fire Sprinkler System for basement only. -- NOTE-- System is required to be monitored Use/Nature of Work -- NOTE-- System is required to be monitored HVAC ContractorPlumbing Contractor Electric Contractor Fees: Valuation$9,000.00Plan Approval$0.00Permit Fee Paid$68.00Park Dedication$0.00 12/19/200500/00/0000 Issued By:DateFinal/O.P. Permit Voided Parcel Id #1329401200 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. SignatureDate Agent/Owner 201 Morris CourtFond du LacWI549360000920-921-9020 Address-Telephone Number To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. '0 OSHKOSH ON THE WATER Job Address 2980-2990 UNIVERSAL ST CITY OF OSHKOSH No 117627 BUILDING PERMIT. APPLICATION AND RECORD Owner OSHKOSH OFFICE BUILDING LLC Create Date 12/19/2005 Designer Contractor AHERN FIRE PROTECTION Category 223 - Alteration Offices, Banks, Professional Plan Q2-70-0805 Type . Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning Class of Const: Size Unfinished/Basement ~Sq.Ft. ~Sq.Ft. Rooms 0 Height OFt. D Projection I Finished/Living Bedrooms 0 Stories Canopies ~ Garage ~Sq.Ft. Baths Signs 0 Foundation . Poured Concrete 0 Floating Slab 0 Concrete Block 0 Post 0 Pier 0 Treated Wood 0 Other Occupancy Permit Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures ~ Use/Nature pfficellnstallatlon of Automatic Fire Sprinkler System for basement only. NOTE System is required to be monitored of Work HVAC Contractor Plumbing Contractor Electric Contractor $9,000.00 Plan Approval $0.00 Permit Fee Paid $68.00 Park Dedication $0.00 Fees: Valuation Issued By: Date 12/19/2005 Final/O.P. 00/00/0000 D Permit Voided I Parcelld # 1329401200 In the performance of this work I a9ree to perform all work pursuant to rules 90veming the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address 201 Morris Court AgenUOwner Fond du Lac WI 54936 - 0000 Telephone Number 920-921-9020 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. " Co ~. Ahern Fire Protection A division of J. F. Ahern Co. Wisconsin' Illinois' Missouri' Nebraska' Iowa' Minnesota Q '2.. -16- (YàQS-' RECEIVED DEe 1 22005 DEPARTMENT OF COMMUNITY DEVELOPMENT Ahern Fire Protection Division J.F. Ahern Co. 201 Morris Court Fond du Lac, WI 54936-1316 920-921-9020 Job Name Building Location System Contract Data File : MIDWEST : Basement : 2990 Universal Street : Entire : 991971 : 991971.wx1 Oshkosh,Wl54901 r Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ahern Fire Protection MIDWEST . , Page 1 Date 120705 '..'¡ Hydraulic Desiqn Information Sheet Name - Midwest General Contractors Location - 2990 Universal Street Building - Basement Contractor - Ahern Fire Protection Calculated By - TJulka Construction: (X) Combustible () Non-Combustible Occupancy - Ordinary Group' 2 Date - 12-8-05 Oshkosh, WI 54901 System No. - Entire Contract No. - 991971 Drawing No. - FP-l Ceiling Height - 9' -4" ...., S Y S T E M (XI NFPA 13 () Lt. Haz. ( I NFPA 231 ( I NFPA 23lC Other Specific Ruling Ord.Haz.Gp. ( ) 1 (X) 2 ( I 3 () Ex.Haz. ( ) Figure Curve Area of Sprinkler Operation - 900 Densi ty - .2000 Area Per Sprinkler - 130.000 Elevation at Highest Outlet - 108.500 Hose Allowance - Inside' - N.A. Rack Sprinkler Allowanèe - N.A. Hose Allowance - Outside - 250 Made By Date D E S I G N Note System Type (X) Wet ( ) Dry ( I Deluge ( I Preaction ( ) Other Sprinkler /Nozzle Make Viking Model VK350 Size 3/4" K-Factor 8.0 Temp.Rat.200 Calculation Summary Flow Required - 262.36 Press Required - 55.41 Base of Riser C-Factor Used: 120 Overhead 140 Underground Water Flow Test: Date of Test - 9-9-05 Time of Test Static Press - 76 Residual Press - 68 Flow - 1061 Elevation - 88 W A T E R S U P P L Y C 0 M M S R T A 0 C R K A G E Pump Data: Rated Cap.- @ Press Elev. Tank or Reservoir: Cap. - Elev. - ....I Location - Washburn & Hwy 44 Source of Information - AFP & Oshkosh Water Dept. Well Proof Flow Commodity Storage Ht. Storage Method: Solid Piled Class Area % Location Aisle W. Palleti zed Rack ( ) Single Row ( ) Double Row ( ) Mult. Row ( ) Conven. Pallet ( ) Slave Pallet ( ) Encap. ( ) Non ( ) Auto. Storage ( ) Solid Shelf ( ) Open Shelf Flue Spacing Longi tudinal Clearance: Storage to Ceiling Transverse Horizontal Barriers Provided: ...,I Computer Programs by Hydratec Inc. Route 111 Windham NH USA 03087 Water Su-) Curve (C) Ahern Fire Protection MIDWEST ) Page 2 Date 120705 City Water Supp..lY: C1 - Static Pressure: 76 C2 - Residual Pressure: 68 C2 - Residual Flow: 1061 Demand: D1 - Elevation D2 - System Flow D2 - Srstem Pressure Hose Adj City) Hose Demand) D3 - S',Istem Demand Safety Margin : 8.879 : 262.359 : 67.321 : ::ZSO---' : 512.359. : 6.598 150 140 130 P 120 R 110 E 100 S 90 S 80 U70 R60 E 50 40 30 20 10 ~. ('.2 17 D3 ';'< D1 200 400 600 800 1000 1200 FLOW ( N ^ 1.85 ) 1400 1600 1800 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Ahern Fire Protection Page 3 MIDWEST Date 120705 Fitting Legend Abbrev. Name Y, % 1 1X 1y, 2 2y, 3 3y, 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow Thrd 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Flanged Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90' Grvd Firelock Elbow 0 0 0 2.1 2.6 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 J 90' Grvd Vic Firelock Tee 0 0 0 5.3 6.35 8.5 10.8 13 0 16 21 25 33 0 0 0 0 0 0 0 T 90' Flow Thru Thread Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90' Flanged Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 25 28 32 36 44 X Flanged Tee 90' Turn 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 44 51 58 65 80 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Zia Wilkens 350 Fitting generates a Fixed Loss Based on Flow ( Computer Programs by Hydratec 1,( .oute 111 Windham N.H. USA 03087 (. t , PF~55ure I Flow Sumrnary - STANDARD , Ahern Fire Protection Page 4 MIDWEST Date 120705 í~~de Elevation K-Fact PI Pn Flow Density Area Press Actual Actual Req. SO01 98.33 8 10.56 na 26.0 0.2 130 7.0 5002 98.33 8 10.56 na 26.0 0.2 130 7.0 S103 108.5 5.6 12.76 na 20.0 0.2 100 7.0 S104 108.5 5.6 15.21 na 21.84 0.2 100 7.0 5105 97.33 K= K@EQ01 12.12 na 26.57 5106 97.33 K= K@EQ02 14.41 na 28.22 5107 97.33 K= K@EQ02 16.82 na 30.48 S108 97.33 K= K@EQ02 22.26 na 35.07 8102 97.33 35.46 na S109 97.33 K= K@EQ01 33.9 na 44.44 X109 97.33 38.88 na 8103 97.33 40.81 na S101 97.33 K= K@EQ01 12.54 na 27.04 S102 97.33 K= K@EQ02 14.91 na 28.7 X103 97.33 20.22 na X1O4 97,33 23.13 na B101 97.33 36.37 na A101 97.33 40.24 na A102 97.33 41.18 na A103 97.33 41.72 na A104 97.33 50.4 na TOR 97.33 54.08 na BOR 97.33 55.41 na UGO1 92.0 63.81 na TEST 88.0 67.32 na 250.0 The maximum velocity is 18.3 and it occurs in the pipe between nodes S108 and B102 r Computer Programs by Hydratec Inc, Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams " " Ahern Fire Protection Page 5 MIDWEST Date 120705 Hyd. Qa Dia. Fitting Pipe pt pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn ....", SO01 26.00 1.08 1E 2.305 1.000 10.562 K Factor = 8.00 to 120 0.0 2.305 0.433 EQ01 26.0 0.1837 0.0 3.305 0.607 Vel= 9.11 0.0 26.00 11.602 K Factor = 7.63 SO02 26.00 1.08 1T 5.762 1.000 10.562 K Factor = 8.00 to 120 0.0 5.762 0.433 EQ02 26.0 0.1835 0.0 6.762 1.241 Vel= 9.11 0.0 26.00 12.236 K Factor = 7.43 S103 20.00 1.08 2E 4.61 12.875 12.755 K Factor = 5.60 to 120 1T 5.762 10.372 4.838 X103 20.0 0.1129 0.0 23.247 2.625 Vel = 7.00 0.0 20.00 20.218 K Factor = 4.45 S104 21.84 1.08 2E 4.61 12.875 15.207 K Factor = 5.60 to 120 1T 5.762 10.372 4.838 X104 21.84 0.1329 0.0 23.247 3.089 Vel= 7.65 0.0 ...." 21.84 23.134 K Factor = 4.54 S105 26.57 1.08 0.0 12.000 12.120 K Factor @ node EQ01 to 120 0.0 0.0 0.0 S106 26.57 0.1911 0.0 12.000 2.293 Vel= 9.31 S106 28.22 1.408 0.0 12.000 14.413 K Factor @ node EQ02 to 120 0.0 0.0 0.0 S107 54.79 0.2002 0.0 12.000 2.403 Vel = 11.29 S107 30.48 1.408 0.0 12.000 16.816 K Factor @ node EQ02 to 120 0.0 0.0 0.0 S108 85.27 0.4538 0.0 12.000 5.446 Vel = 17.57 S108 35.07 1.639 2E 8.727 23.500 22.262 K Factor @ node EQ02 to 120 0.0 8.727 0.0 8102 120.34 0.4097 0.0 32.227 13.203 Vel = 18.30 8102 0.0 2.104 1T 10.902 36.160 35.465 to 120 0.0 10.902 0,0 A102 120.34 0.1214 0.0 47.062 5.713 Vel = 11.10 0.0 120.34 41.178 K Factor = 18.75 S109 44.44 1.08 1E 2.305 2.000 33.898 K Factor @ node EQ01 to 120 1T 5.762 8.067 0.0 X109 44.44 0.4947 0.0 10067 4.980 Vel = 15.56 X109 0.0 1.639 2E 8.727 21.120 38.878 --' to 120 0.0 8.727 0.0 8103 44.44 0.0649 0.0 29.847 1.937 Vel = 6.76 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fmal Calculations - Standard , Ahern Fire Protection Page 6 MIDWEST Date 120705 rHyd. Qa Dia. Fitting Pipe pt pt . Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn B103 0.0 2.104 1T 10.902 36.160 40.815 to 120 0.0 10.902 0.0 A103 44.44 0.0192 0.0 47.062 0.904 Vel= 4.10 0.0 44.44 41.719 K Factor = 6.88 S101 27.04 1.08 0.0 12.000 12.544 K Factor @ node EQ01 to 120 0.0 0.0 0.0 S102 27.04 0.1972 0.0 12.000 2.367 Vel = 9.47 S102 28.70 1.408 1E 3.308 15.750 14.911 K Factor @ node EQ02 to 120 1T 6.617 9.925 0.0 X103 55.74 0.2067 0.0 25.675 5.307 Vel = 11.49 X103 20.00 1.408 0.0 8.000 20.218 to 120 0.0 0.0 0.0 X104 75.74 0.3645 0.0 8.000 2.916 Vel = 15.61 X104 21.84 1.639 3E 13.09 25.790 23.134 to 120 1T 8.727 21.817 0.0 B101 97.58 0.2779 0.0 47.607 13.231 Vel = 14.84 r 'B101 0.0 2.104 1T 10.902 36.160 36.365 to 120 0.0 10.902 0.0 A101 97.58 0.0824 0.0 47.062 3.876 Vel= 9.00 A101 0.0 2.703 41 26.733 11.790 40.241 to 120 0.0 26.733 0.0 A102 97.58 0.0243 0.0 38.523 0.937 Vel = 5.46 A102 120.34 2.703 0.0 5.040 41.178 to 120 0.0 0.0 0.0 A103 217.92 0.1073 0.0 5.040 0.541 Vel = 12.18 A103 44.44 2.703 41 26.733 13.750 41.719 to 120 1J 16.786 43.519 0.0 A104 262.36 0.1515 0.0 57.269 8.679 Vel = 14.67 A104 0.0 3.314 11 7.279 58.208 50.398 to 120 0.0 7.279 0.0 TOR 262.36 0.0562 0.0 65.487 3.678 Vel= 9.76 TOR 0.0 3.314 1Z 10.191 6.208 54.076 to 120 11 7.279 17.470 0.0 BOR 262.36 0.0562 0.0 23.678 1.330 Vel= 9.76 BOR 0.0 3.314 1Zia 0.0 3.625 55.406 to 120 0.0 0.0 8.196 * Fixed loss = 5.888 UG01 262.36 0.0563 0.0 3.625 0.204 Vel= 9.76 r~G01 0.0 4.22 1G 3.345 50.000 63.806 140 1V 16.726 86.974 1.732 TEST 262.36 0.0130 2X 66.903 136.974 1.783 Vel= 6.02 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Ahern Fire Protection MIDWEST Page 7 Date 120705 Hyd. Ref. Point Qa Dia. Fitting or Eqv. Ln. Pipe Ftng's Total pt Pe Pf pt Pv Pn Notes ****** ..., "C" Qt Pf/Ft 250.00 512.36 67.321 Qa = 250.00 K Factor = 62.45 ....I ...,I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087