HomeMy WebLinkAbout2006-Building Type CITY OF OSHKOSH ![ BUILDING PERMIT . APPLICATION AND RECORD I ~::i:::~SS 515 S WASHBURN ST :~:~:OMP::S~::::~T:::LLC :I~:te DI..al te 01/23/2006 Category 223 - Alteration Offices. Banks. Professional I Site ~ Projection I yanOPies igns 0 OSHKOSH ON THE WATER 117950 . Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning Class of Const: Unfinished/Basement ~Sq.Ft. ~Sq.Ft. Rooms 0 Height 0 Ft. Finished/Living Bedrooms Stories 2 Garage ~Sq.Ft. Baths 0 Foundation 0 Poured Concrete 0 Floating Slab 0 Concrete Block 0 Post 0 Pier 0 Treated Wood . Other Occupancy Permit Required Flood Plain Height Permit Park Dedication # Dwelling Units ~ # Stru~ures 0 Use/Nature uite 204 / Remodel and combine a portion of suite 205 into this suite. Relocate doors, walls, remodel bath to be acce ible.' Note: of Work Plan review is not complete at this time. contra~or is proceeding at own risk. HVAC Contractor Plumbin9 Contractor Electric Contra~or Fees: Valuation ,800.00 Plan Approval $0.00 Permit Fee Paid $193.00 Park Dedication $0.00 Issued By: Date 01/23/2006 Fina /O.P. 00/00/0000 0 Permit Voided I Parce Id # 0614620000 Date / Signature Address 5711 GREEN VALLEY RD AgenUOwner OSHKOSH 'J\/I. 54904 - 0000 Telephone Number 231-8 35 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Nu ber, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Na: e and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received' Work may continue if the inspection is not performed within two business days from the time the project is ready. ~ OJHKOfH ON THE WATER City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903.1130 www.ci.oshkcsh.wi.us January 24, 2006 Rick Schroeder AIA 581 North Main Street Oshkosh WI 54901 Compass Properties LLC 1145 Clark Street Stevens Point WI 54481-2980 Site: Fox Valley Dennatology 515 South Washburn St Suite 204 Oshkosh WI 54901 For: Description: Tenant space alterations Object Type: Building only Class of Construction: IIIB - 2866 Sq Ft.; Unsprinklered Occupancy: B: Business / Office Maximum No of Occupants: 29 Plan Number: R4-02-0106 The subutittal described above has been reviewed for confonnance with applicable Wisconsin Adutiuistrative Codes and Wisconsin Statutes. The subutittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) / Conditions: IBC 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping system that matches the rating of the wall assembly being penetrated, Copies of the firestopping systems are required to be provided at the time of inspection, IBC 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. . 1003.2.3.1 Door encroachment. Doors opening into the path of egress travel shall not reduce the required width to less than one-half during the course of the swing. When fully open, the door shaH not project more than 7 inches (178 rom) into the required width. Based on phone conversation with Architect, the door from the bathroom (D212) will be changed to swing into the bathroom, and stül meet accessibility requirements. mc 1003.2.10 Exit signs are required to be installed per this section IBC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimurn 6 inches up onto walls. Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installationofHV AC equipment. Be aware that mc 1004.3.2.4 contains additional restriction for air movement in corridors ¡¡ :\orirum'2006 Cornm Ph," Review\R4.02.0 [06515 Soud, Washoum 5t Bldg Only. doc Page I of2 Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. An revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Corom6L31(1). SUBMIT: mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. . Comm 61.50 (4) Snpervision. Prior to the initial occupancy of an alteration the supervising professional shan file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pennits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this reviei shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. ri oe Building Systems Consultant (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30AM and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 390.00 390.00 0,00 It\bnann'2006 Comn> Plan R.vi."'.R4.02.(JIO6 515 Souù, Washbun> 51 Bldg Only.doc Page 2 of2