HomeMy WebLinkAboutHVAC Q3-78-0905-H
~
OJHKOIH
ON THE WATER
City of Oshkosh
Division ofInspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.ci.oshkosh.wi.us
January 5, 2006
Chad Landsinger
Lennox Industries, Inc
3102 E Edgemere Dr
Appleton WI 54915
Art Dumke
Dumke Management
601 Oregon St
Oshkosh WI 54902
Site:
Oniell Enterprises
522 W 6th Ave
Oshkosh WI 54902
For:
Description: HV AC for Construction of office space within storage bnilding
Object Type: HV AC only
Class of Construction: 1m - 3300 Sq Ft.; Unsprinklered
Occupancy: S: Storage, B: Business I Office
Plan Number: Q3-78-0905-H
(Dated 12-22-05)
The submittal described above has been reviewed for confonnance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as deemed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code reqnirements
NOTE: - The top side of the ceiling framing will not be sheeted, and the area above the offices is NOT TO BE USED FOR
STORAGE! Revised plans are reqnired to be submitted for review prior to this area being used for storage, or any
additional equipment being placed in this location.
Key Item(s) I Conditions:
.
IMC 304.1 Equipment and appliances shall be installed as required by the terms of their approval, in
accordance with the conditions of the listing, the manufactures instructions and this code. Verify that
CO and NO2 detectors are installed per their allowed coverage areas.
.
Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which
involve rules under this code and which are made to construction documents that have previously been
granted approval by the department or its authorized representative, shall be submitted to the office
that granted the approval. All revisions and modifications to plans shall be approved in writing by the
department or its authorized representative prior to the work involved in the revision or modification
being catried out. A revision or modification to a plan, drawing or specification shall be signed and
sealed in accordance with Comm 61.31(1).
'.\OSIlKOSIIMISFS\US.ERS\briann\2006 Cumin Plan Re,;ew\Q3.78-09iJS-II 522 w 6th "'" HVAC Only.doc
Page 1 of2
.
MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully
screened from view of any street or residential zoning district. Contact David Buck - Associate planner
(920) 236- 5062 for additional information on screening requirements. All screening shall be properly
anchored in place to resist wind loads. Additionally IBC 1608.8 Roofprojections - Drift loads due to
mechanical equipment, penthouses, parapets and other projections above the roof shall be detern1Ìned
in accordance with Section 7.8 of ASCE 7. No HV AC permit will be issued until screening plan
has been approved.
Note: If the AlC condenser were located on the gronnd, screening wonld be more easily accomplished,
and there would be no requirement for the permanent ladder to the roof as noted in item No. 10.
SUBMIT:
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
. IECC 503.3.3.7 [Comm 63.0503(2)(t)] Balancing and documentation of the HV AC system shall conform
to the !MC. Balancing report required to be submitted prior to final occupancy being allowed.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pennits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe bnilding, structore, or component.
Inqniries concerning this correspondence may be made to me at the nnmber listed below or the address on this letterhead.
Re~p~/
:Z?ø-
Bnilding Systems Consultaot
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30A.M and 12:30A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
300.00
300.00
0.00
\\OSIlKOSHMISF$\USERS\brÜum\2006 Comln Phi!! Rov;ow\Q3-78'()905-fI 522 w 6th aye !IV AC Only.doo
Page 2 of2