Loading...
HomeMy WebLinkAbout0010627 e OSHKOSH ON THE WATER Issue Date 12/19/05 Address Sent to Introduction Item # Description 12/19/05 Last Updated Item # Description 12/19/05 Last Updated INSPECTION SERVICES DIVISION ROOM 205 DEPARTMENT OF COMMUNITY DEVELOPMENT CORRECTION NOTICE CITY OF OSHKOSH 215 CHURCH AVE PO Box 1130 OSHKOSH WI 54903-1130 -- Compliance Date 1/18/06 Compliance No 138 W SOUTH PARK AVE ~ Owner Name Address I ERNEST/DOLORES ROTHE LIFE ESTAl 138 W SOUTH PARK AVE City OSHKOSH State Zip Code WI 54902 -6536 U Required for Occupancy I Occupancy Sin91e Family he following violations were noted at the final inspection of the deck/handicap ramp. Code COMM 21.04 Compliance No Compliance Date 01/18/2006 Handrails must be graspable and symmetrical about the vertical centerline to allow for equal wraparound of the thumb and ,"gers. Handrails with a round cross sectional gripping surface shall have a maximum whole diameter of 2". Handrails with a ectangular cross sectional gripping surface shall have a maximum perimeter of 6 1/4" with a maximum cross sectional imension of 27/8". 2 Code COMM 21.02 Compliance No he shear nails are required to be installed for the joist hangers. Compliance Date 01/18/2006 Item # 3 Code MUN 21.045 Compliance No Compliance Date 01/18/2006 Description Ramps shall have a slip resistant surface. A level landing shall be installed at the end of the ramp. 12/19/05 Last Updated 10627 Page 1 of2 e OSHKOSH ON THE WATER Issue Date 12/19/05 INSPECTION SERVICES DIVISION ROOM 205 DEPARTMENT OF COMMUNITY DEVELOPMENT CORRECTION NOTICE CITY OF OSHKOSH 215 CHURCH AVE PO Box 1130 OSHKOSH WI 54903-1130 -- Compliance Date 1/18/06 Compliance No Address 138 W SOUTH PARK AVE Name Address I ERNESTIDOLORES ROTHE LIFE ESTAl 138 W SOUTH PARK AVE Sentto ~ Owner City OSHKOSH State Zip Code WI 54902 -6536 Introduction U Required for Occupancy I Occupancy Sin91e Family he following violations were noted at the final inspection of the deck/handicap ramp. Item # 4 Code COMM 21.02 Compliance No Compliance Date 01/18/2006 Description Lag bolts are required to be installed per the minimum code requirements. A minimum of two 1/2" bolts are required every 16" /c for the deck ledger. 12/19/05 Last Updated Summarv he violations shall be corrected and approved within the next30 days. If you have any questions feel free to contact me at 36-5036. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 1/18/06 Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the Si9:::~::Of()~~~ Date JZI(Cjfa~ Inspected by: Nicole Krahn 236-5036 nkrahn@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: U Bld9 U Elec U HVAC U Plbg U Designer U Other U Inspector --- --- --- --- --- -- -0000 10627 Page 2 of 2