HomeMy WebLinkAbout0117607-Building e OSHKOSH ON THE WATER Job Address 460470480 N MAIN ST CITY OF OSHKOSH No 117607 BUILDING PERMIT - APPLICATION AND RECORD Owner BENT BLOCK OSHKOSH LLC Create Date 12/15/2005 Designer Rick Schroeder Contractor OWNER Category 223 - Alteration Offices, Banks, Professional Plan R4-114-1205 Type . Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning Class of Const: 3B Size Unfinished/Basement ~sq.Ft. ~sq.Ft. Rooms 0 Height 0 Ft. D Projection I Finished/Living Bedrooms 0 Stories Canopies 0 Garage ~Sq.Ft. Baths Signs ~ Foundation . Poured Concrete 0 Floating Siab 0 Concrete Biock 0 Post 0 Pier 0 Treated Wood 0 Other Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Not Required # Dwelling Units 0 # Structures ~ Use/Nature ofWork 60/ interior aiterations as per pians. HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $14,500.00 Plan Approval $0.00 Permit Fee Paid $99.00 Park Dedication $0.00 Issued By: Date 12/1512005 Final/O.P. 00/00/0000 D Permit Voided I Parcelld # 0400940000 In the performance of this work I agree to perform all work pursuant to ruies governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongiy urges the permit appiicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address AgenVOwner Oshkosh Wi 54901 - 0000 Telephone Number To schedule inspections please cali the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. (t) OfHKOIH ON THE WATER City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wLus December 15, 2005 Rick Schroeder 581 North Main St Oshkosh, WI 54901 Peter Jungbacker Bent Block Oshkosh LLC 377 City Center Oshkosh, WI 54901 Site: WGH Hospitality 460 North Main St Oshkosh WI 54901 Plan Number: R4-114-1205 For: Description: Tenant space alterations Object Type: Building only Class of Construction: llIB - 1545 Sq Ft.; Sprinklered Occupancy: Mercantile I Retail The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statntes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wjsconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: . ANSI 303.4 Changes in level greater than Y, inch shall be ramped in compliance with Section 405 or 406. Comm 62.1110 Signage (2)Directional signage. Directional signage indicating the route to the nearest like accessible element within the building or facility shall be provided at all ofthe locations specified in pars. (a) to (e). These directional signs shall include the International Symbol of Accessibility. (a) Inaccessible building entrances. IrMain Street entrance is not accessible provide proper signage directing persons to rear entrance. mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through The Retail Display area are required to have adequate emergency lighting to meet the performance requirements ofIBC 1003.2.11.3. Depending on configuration of store displays and racking additional emergency illumination may be required to comply with these requirements. COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. . mc 2406.2 Glazing in an individual fixed or operable panel adjacent to a door where the nearest exposed edge of the glazing is within a 24 inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface is requires safety glazing materials. H:\briann\2005 Comm Plan Review$'R4-JI4-1205 bldg nniy 460 N Main Stdoc Page 1 of3 mc 2902..11 Table 2902 Drinking water is required to be provided, since no drinking fountain is shown on plans a bottled water cooler is required to be provided. IFC 901.4 Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting plans and calculations shall be prepared in compliance with the code. The plans shall be available upon request. Comm 61.30(3) 1 IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HVAC plans are required to be submitted and approved prior to installation ofHV AC equipment. Be aware that IBC 1004.3.2.4 contains additional restriction for air movement in corridors Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). MUN 30-35 (1)(5) All roof top and ground level mechanical equipment and utilities shall be fully screened from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. Additionally IBC 1608.8 Roofprojectjons - Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. SUBMIT: mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through The Retail Display area are required to have adequate emergency lighting to meet the performance requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. !I:\briwm'2Q()j C:o1O1o Plan Review,\R4-] 14-1205 bldg only 460 N Main St.doc Page 2 of3 Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. Re.s~ R~ Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 AM to 1:30 P.M. bnoe@cLoshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 !1:\bri~m\200j Comm I'"n Review,\R4-1 i4-1205 bkig oniy 460 N Main Stdoc Page30f3