Loading...
HomeMy WebLinkAbout0118358-HVAC e OSHKOSH ON THE WATER Job Address 320 E FERNAU AVE CITY OF OSHKOSH No 118358 HVAC PERMIT - APPLICATION AND RECORD Owner M BRICKHAM HOLDINGS LLC Create Date 02124/2006 Plan R1-109-1105 1 1 Oil Category 512 - Ind. & Comm-Both 1"1 Electric I 1 Solar I I Solid Contractor MCM AIR INC Fuel 1"1 Gas System 0 New ~ Forced Air I 1 Electric Chimney Type Chimney A Heat Loss K ) As Approved BTU Rate K ) As Per Plan U Radiant I I HotWater n Replace U Steam I I Suppl. n Other U Vent Chimney B ( ) Existing Direct Vent ~NC I I 1 Con. Burner I Not Applicable Use/Nature Install FA HVAC system for offices on mezzanine. - Equipment required to be screend per plan on file. ofWork ( ) Variable . Not Applicable . Other Value Value Fees: Valuation $11,000.00 Plan Approval $0.00 Permit Fee Paid $165.00 Issued By: Date 03/0212006 D Permit vo~ Parcelld # 1519603100 In the performance of this work, I a9ree to perform all work pursuant to rules govemin9 the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date AgenVOwner Address 6122 COUNTY ROAD M WINNECONNE WI 54986 - 9780 Telephone Number 920-582-4402 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. ~ OIHKOfH ON THE WATER City of Oshkosh Division ofInspection Services 215 Church Avenue PO Box mo Oshkosh WI 54903-1130 www.cLoshkosh.wLus December 5, 2005 Mark Christens Temperature Systems Inc. 2200 S Ashland Ave Green Bay, WI 54304 M Brickham Holdings LLC 320 E Fernau Ave Oshkosh, WI 54901 Site: Brickham Machine Co 320 E Fernau Ave Oshkosh WI 54901 For: Description: Tenant space alterations Object Type: HV AC only Class of Construction: TIm - 2400 Sq Ft.; Occupancy: B: Business Office Plan Number: R1-109-1105-H Uusprinklered The submittal described aboye has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as deemed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: mc 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems are required to be provided at the time of inspection. IMC 401.5.1 Mechanical and gravity outside air intake openings shall be located a minimum of 10 feet from any hazardous or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks. 401.5.2 Exhaust openings. Outside exhaust openings shall be located so as not to create a nuisance. Exhaust air shall not be directed onto walkways. MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. Additionally mc 1608.8 Roofprojections - Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. Provide detail showing AlC location and screening. No HV AC permit will be issued until screening plans have been provided and approved. Page 1 of2 SUBMIT: IECC 503.3.3.7 [Comm 63.0503(2)(1)] Balancing and documentation ofthe HV AC system shall conform to the !MC. Balancing report required to be submitted prior to final occupancy being allowed. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. Respe~¿ ~ Building Systems Consultant (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.Mto 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 230.00 230.00 0.00 (\)<1'01 Pian ,\". Only.doc Page20f2 HVAC Permit Work Card Job Address 320 E FERNAU AVE Permit Number 118358 Create Date 02/24/2006 Owner M BRICKHAM HOLDINGS LLC Contractor MCM AIR INC Category 512 -Ind. & Comm-Both Plan R1-109-1105 Fuel ~ IT2C:J ~ Electric I ~ ~ Value $11,000.00 System PI New n Replace 1 D Other I ~ Forced Air I []Radiant I U Steam I ~C I U Vent I U Electric I U Hot Water I U Suppl. I llion. Burner I Chimney Type ,0 Chimney A 0 Chimney B 0 DirectVent . Not Applicable Heat Loss P As Approved 0 Existing . Not Applicable I Value BTU Rate 0 As Per Plan 0 Variable . Other I Value Use/Nature Install FA HVAC system for offices on mezzanine. - Equipment required to be screend per plan on file. of Work Inspections: Date 1/25/2006 Type Inspector Allyn Dannhoff approved NO CONCERNS NOTED-CLOSE FILE WHEN HVAC PERMIT IS ISSUED / HVAC PERMIT ISSUED 3/2/06 DatelTime requested: Notice Type: Phone Number: Access: Ready DatelTime: Requested By: 0 Reinspect Fee 0 Fee Waived D Reinspect Fee Paid