HomeMy WebLinkAbout2003-Plans
~
OSHKOSH
ON THE WATER
INSPECTION SERVICES DIVISION
DEPARTMENT OF COMMUNITY DEVELOPMENT
Room 205
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Issue Date ~ Compliance Date 5/31/03 IMMEDIATELY
Address 425 N WASHBURN ST
Inspected By
Compliance No
Allyn Dannhoff 236-5045
City State Zip Code
OSHKOSH WI 54904 -7810
---
APPLETON WI 54915 -0000
OSHKOSH WI 54901 -0000
---
Name
I SHORELAND DEVELOPMENT CORP
1 R&RSTEEL
I AEC
Address
237 N WASHBURN ST
5521 W PROSPECT AVE
5703 CTY RD A
Sent to
~ Owner
~ Contractor
~ Other
~ Inspector I Matt Tucker
U Required for Occupancy 1 Occupancy Commercial Notice D First . Final I::) Other
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 5/31/03
Introduction Inspection on 5-1-03 revealed the following items to be corrected immediately.
Item # Code COMM 51.02(15) Compliance No Compliance Date 05/31/2003 IMMEDIATELY
Description Per the 8-7-02 plan review letter, provide the Wisconsin Material Approval Number and assembly description that verifies the
EIFS is a non-combustible material. Also make this installed system available for inspection to verify all the elements used
rein compliance with the Wisconsin Material Approval. Failure to comply will result in denial of Occupancy Approval.
Item # Code COMM50.12 Compliance No Compliance Date 05/31/2003 IMMEDIATELY
Description Revised plans shall be sent to DOC for review and approval to include the mezzanine. A copy of the stamped state approved
plans shall be provided to this office.
Item # Code 7-8 Compliance No Compliance Date 05/31/2003 IMMEDIATELY
Description fi'. Building Permit shall be secured for the mezzanine described in #2. The mezzanine floor system and surrounding walls
þhall not be covered until plans have been approved, permit obtained and an inspection performed to determine compliance.
Item # 4 Code 7-31 Compliance No Compliance Date 05/31/2003 IMMEDIATELY
Description The General Contractor has failed to request inspections prior to proceeding beyond various stages of construction. This was
brought to their attention at the start of this project when footings were being placed. Continued violation of this codesection
ill result in citation issuance to the General Contractor.
'í{ogz.
Page 1 of2
~
OSHKOSH
ON THE WATER
INSPECTION SERVICES DIVISION
DEPARTMENT OF COMMUNITY DEVELOPMENT
Room 205
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Name
~ Owner I SHORELAND DEVELOPMENT CORP
~ Contractor I R & R STEEL
~ Other I AEC
~ Inspector I Matt Tucker
U Required for Occupancy I Occupancy Commercial Notice I::) First . Final () Other
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 5/31/03
Introduction Inspection on 5-1-03 revealed the following items to be corrected immediately.
Compliance No
Inspected By Allyn Dannhoff 236-5045
Address City State Zip Code
237 N WASHBURN ST OSHKOSH WI 54904 - 7810
5521 W PROSPECT AVE APPLETON WI 54915 -0000
Issue Date ~ Compliance Date 5/31/03 IMMEDIATELY
Address 425 N WASHBURN ST
Sentto
5703 CTY RD A
OSHKOSH
WI 54901 -0000
Item #
Description
Code 30-35(1)(5) Compliance No Compliance Date 05/31/2003 IMMEDIATELY
Rooftop Mechanical Equipment has been installed on the roof, when the plans submitted for the building permit did not show
his equipment. Specifically, this section states; All roof top and ground level mechanical equipment and utilities shall be fully
creened from view of any street or residential zoning district. The screening must be approved by the Planning Division. prior
0 installation and must be installed prior to Occupancy Approval.
Summary
all for a reinspection prior to covering any structural items. All items must be corrected prior to Occupancy Approval.
DEFICIENCIES MUST BE CORRECTED AND APPR~V~ CONCEALMENT. CALL (920) 236-5050 FOR I~~PJ N. F'")
Signature ~ Date V
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name
Company
Signature
Date
Page20f2