Loading...
HomeMy WebLinkAbout0117599-HVAC G OSHKOSH ON THE WATER Job Address 3596 STEARNS DR CITY OF OSHKOSH No 117599 HVAC PERMIT -APPLICATION AND RECORD Owner DANIEL E DOWLING Create Date 12/15/2005 Plan Q5-85-0905-H Category 512 -Ind. & Comm-Both I I Electric Contractor GARTMAN MECHANICAL SERVICES Fuel 1,(1 Gas [7] New l!J Forced Air I I Electric I I Oil I I Solar I I Solid n Replace U Steam I I Suppl. n Other System Heat Loss . As Approved . As Per Plan ( ) Chimney B ( ) Existing . Direct Vent l!J AlC I I I Con. Burner I ( ) Not Applicable U Vent U Radiant I I Hot Water Chimney Type U Chimney A BTU Rate ( ) Variable ( ) Not Applicable ( ) Other Value 0 Value Use/Nature omm/ Early Start HVAC sy1em for office / reception and toilet rooms as per plans. - No Work to be concealed prior to plans being of Work pproved Screening to be installed per building plans provided. Fees: Valuation $17,640.00 Plan Approval $0.00 Penmit Fee Paid $282.00 Issued By: Date 12/15/2005 D Permit Voided I Parcelld # 1278800000 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the penmit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address PO BOX 2264 OSHKOSH WI 54903 - 2264 Telephone Number (920) 231-5530 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1 130 www.ci.oshkosh.wi.us ON THE WATER December 9, 2005 Keith Paul GMS Iuc 520 W SouthparkAve Oshkosh, WI 54903 Dan Dowling PO BOX 3045 Oshkosh WI 54903 Site: 3596 Sterns Dr Oshkosh WI 54901 For: Description: Sunset School Conversion ObjectType: HV AC only Building Type: VB - 4074 Sq. Ft. (Phase 1 ONLY) Unsprinklered Occupancy: B: Business S1, S2, :Storage Plan Nnmber: Q5-85-0905-H The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: ¡MC 302.1 The building or structure shall not be weakened by the installation of mechanical systems. VerifY that existing structure is capable of supporting the additional weight of the proposed rooftop equipment. ¡MC 304.9 Guards. Guards shall be provided where appliances, equipment, fans or other components that require service are located within 10 feet (3048 rom) of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches (762 rom) above the floor, roof or grade below. The guard shall extend not less than 30 inches (762 rom) beyond each end of such appliance, equipment, fan or component and the top of the guard shall be located not less than 42 inches (1067 rom) above the elevated surface adjacent to the guard. The guard shall be constructed so as to prevent the passage of a 21-inch- diameter (533 rom) sphere and shall comply with the loading requirements for guards specified in the International Building Code. MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened ftorn view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. Additionally mc 1608.8 Roof projections - Drift loads due to mechanical equipment, penthouses, parapets and other proj ections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. Screening is required to be installed per approved building plans \\OSHKOSllMJSPg\USERS\briann\2005 Comm Plan Review,\Q5.85-0905-H 3596 Stem, Dr ¡IVAC Only.dnc Page 1 of2 SUBMIT: IECC 503.3.3.7 [Comm 63.0503(2)(1)] Balancing and documentation of the HV AC system shall conform to the IMC. Balancing report required to be submitted prior to final occupancy being allowed. . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site doting construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. . Resp~ ~ Building Systems Consultant (920) 236-5045 Monday- Friday 7:30 AM. to 8:30 A.M and 12:30 A.M to 1:30 P.M. adannhoff@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 300.00 300.00 0.00 \\OSHKOSHM.lSFS\USERS\bnann\200S Cnmm Plan Re,iews\QS-8S-090S-11359<i Slem, Dc HVAC Only.doc Page20f2 ~ QfHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wi.us ON THE WATER Nov 7,2005 Keith Paul GMS Inc 520 W Southpark Ave Oshkosh, WI 54903 Dan Dowling PO BOX 3045 Oshkosh WI 54903 Site: 3596 Sterns Dr Oshkosh WI 54901 For: Description: Sunset School Conversion Object Type: HV AC only Building Type: VB - 4074 Sq. Ft. (phase 1 ONLY) Unsprinklered Occupancy: B: Business SI, S2, :Storage Plan Number: Q5-85-0905-H The submittal described above that was submitted to our office on October 28 , 2005 has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. Plan Approval is bem!!: WITHHELD pending receipt of additional information and / or revised plan. Please provide the following missing information. Submit: ¡MC 302.1 The building or structure shall not be weakened by the installation of mechanical systems. Provide calculations showing roof structure is capable of supporting additional loads being place on the roof, or provide plans and calculations for any required reinforcement/ alterations. MUN 30-35 (1)(5) All roof top and ground level mechanical equipment and utilities shall be fully screened ftom view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. Additionally mc 1608.8 Roof projections - Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. Provide screening plans for review prior to installation. NOTE: A Permit for HVAC work will not be issued until a screening plan is approved! Inquiries coucerning this correspondence may be made to me at the number listed below or the address on this letterhead. _R~ ~æ--- Building Systems Consultant (920) 236-5045 Monday-Friday 7:30 A.M. to 8:30A.M and 12:30 A.M to 1:30 P.M. adannhoff@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 300.00 300.00 0.00 L¡',hri",m'20(J5 Comm Pian Review"Q5-85-0905-H 3596 Stem, Dr Withheld nv AC Only,doc Page 1 of!