Loading...
HomeMy WebLinkAbout2005-Building Q9-89-1005 ~ OJHmfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wLus ON '"' WA"R October 17,2005 Richard Fisher Fisher & Associates, LLC 642 TholsenDr Kimberly WI 54136 Todd Cmnmings Tod Mar Property Management 434 N Main St Oshkosh, WI 54901 Site: Oblio's 434 N Main St Oshkosh WI 54901 For: Description: Tenant space alterations Object Type: Building only Class ofConstructiou: liB -1225 Sq Ft.; Uusprinklered Occupancy: A-2: Assembly, SI & R2 -NON-SEPARATED USE Maximum No of Occupants: 164 Plan Number: Q9-89-1005 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01 (1 0), Wisconsin Statutes, is. responsible for compliance with all.code requirements Key Item(s) / Conditions: . ANSI 303.4 Changes in level greater than Yz inch shall be ramped in compliance with Section 405 or 406. mc 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems are required to be provided at the time of inspection. mc 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. IBC 1003.2.2.5 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit access doorway !Tom the room or space. Posted signs shall meet the requirement ofmooicipal code section 13-5. Min 12 inches in length, min 4 inches in height with min Yz inch lettering and the numbers being minimum 3 inches in height. The sign shall state "Limit (number) Persons". mc 1003.2.10 Exit signs are required to be installed per this section IBC 1003.2.11 Means of egress illumination is required to be installed per this section mc 2902..1/ Table 2902 Drinking water is required to be provided, since no drinking foootain is shown on plans a bottled water cooler is required to be provided. IFC 304.3 Containers. Combustible rubbish and waste material kept within a structure shall be stored in accordance with Sections 304.3.1 through 304.3.3. \\OSlIKOSlIMJSFS\{'!SERS\briann\2005 Comm Plan R.,;.",\Q6.89.100j 434 N Main SL Bldg Only.do<: Page lof2 IFC 304.3.3 Capacity exceeding 1.5 cubic yards. Dumpsters and containers with an individual capacity of 1.5 cubic yards or more shall not be stored in buildings or placed within 5 feet of combustible walls, openings, or combustible roof eve lines. Comm 61.30(3) 1 IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC equipment. Be aware that IBC 1004.3.2.4 contains additional restriction for air movement in corridors Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules ooder this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm61.31(1). MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened !Tom view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. Additionally IBC 1608.8 Roofprojections - Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. MUN 15 NOTE: Contact Anne Boyce - Health Services (920) 236-5029 for additional information as to Health code requirements. Preliminary review indicates the need for an additional hand wash sink in new bar area. Comm 161 NEC Article 518. Be aware of additional wiring requirements for an assembly area. SUBMIT: IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through The Retail Display area are required to have adequate emergency lighting to meet the performance requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me atthe number listed below or the address on this letterhead. R~ H~ Building Systems Consultant (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30A.M and 12:30 A.Mto 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 '.\OSIIKOSIlMJSFS\USETW.bri,.m\2005 Comm Plan Revie',,\Q6.89.¡OO5 434 N Main S, Bldg Only.doc Page 2 of2