HomeMy WebLinkAbout0116772-HVAC (install)
e
OSHKOSH
ON THE WATER
Job Address 1020-1040 W 20TH AVE
CITY OF OSHKOSH
No
116772
HVAC PERMIT -APPLICATION AND RECORD
Owner
JAMES PETR
Create Date 10/14/2005
Plan P4-46-0705-H
Contractor GARTMAN MECHANICAL SERVICES
1"'1 Gas 1 I Oil
Fuel
System [7] New
~ Forced Air U Radiant
1 1 Electric I 1 HotWater
Chimney Type K) Chimney A C) Chimney B
Heat Loss K ) As Approved C ) Existing
BTU Rate K ) As Per Plan C ) Variable
Category 512 -Ind. & Comm-Both
1"'1 Electric
1 1 Solar
1 1 Soiid
n Replace
U Steam
n Other
~NC 1
1 1 Con. Bumer I
C) Not Applicable
~ Vent
1 1 Suppl.
. DirectVent
. NotAppiicable
. Other
Value
Value
Use/Nature 1024 - Lindekugel's Saion -Instali HVAC equipment as per plans.
of Work
$10,930.00
Plan Approval
$0.00
Permit Fee Paid
$215.00
Fees: Valuation
Issued By:
Date 10/14/2005
D Permit Voided I
Parcelld # 1307110200
In the performance of this work, I agree to perform ali work pursuant to rules goveming the described construction.
While tI1e City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in tI1is permit appiication within an easement, the City strongly urges the pennit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
Signature
Date
AgenUOwner
Address
PO BOX 2264
OSHKOSH
WI 54903 -2264 Telephone Number
(920) 231-5530
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
~
OJH<OIH
City of Oshkosh
Division oflnspe<:tion Services
215 Church Avenue
PO Box mo
Oshkosh WI 54903-1130
www,ci.oshkosh,wi.us
ON THE WATER
Oct 12, 2005
Keith Paul
Gartman Mechanical
520 W Sonth Park Ave
Oshkosh WI 54903
James Petr
Milwukee P.C.
3900 N Shoreburn Plaza
Shorewood WI 53211
Site:
Lindekngel's Salon
1024 W 20th Ave
Oshkosh WI 54902
For:
Description: HV AC system for Tenant space alterations
Object Type: HV AC only .
Class of Construction: 11m - 2100 Sq Ft.; Unsprinklered
Occupancy: B: Business
Plan Number: P4-46-0705-H
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code reqnirements
Key Item(s) / Conditions:
.
IMC 302.1 The building or structure shall not be weakened by the installation of mechanical systems. Per
letter from Bill Montelbano dated 10/7/05 the structure is adequate for equipment - additional
evaluation is requiredfor any screening
IMC 403.3 [Comm 64.0403 (6)] Ventilation rate. Janitor closets. A janitor closet that has only one
service sink may be provided with either natural ventilation via a window or louvered opening with at least
2 square feet (0.2 m2) of area openable directly to the outside or mechanical exhaust ventilation as
specified in Table 64.0403. Per discussion with Keith Paul- additional exhaust will be provided in this
area.
IFGC 304.2 Appliance/equipment location. Equipment shall be located so as not to interfere with proper
circulation of combustion, ventilation, and dilution air. Caution on location of water heater in room with
dryer and exhaust grill- [fwater heater is not an electric, or sealed combustion unit additional
combustion air may be required.
MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened
from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236-
5062 for additional information on screening requirements. All screening shall be properly anchored in
place to resist wind loads. Additionally mc 1608.8 Roofprojections - Drift loads due to mechanical
equipment, penthouses, parapets and other projections above the roof shall be determined in accordance
with Section 7.8 of ASCE 7. Per letter from Jim Petrdated 9/2/05 the required screening will be
completed by December 31,2005. Plans are required to be submitted and approved prior to
installation.
Ii '1>11"",,'.200;
"",,"..;'.1'4.46.<)70;.[1 '024W
IIVACOnly.dü"
Page 1 on
SUBMIT:
IECC 503.3.3.7 [Comm 63.0503(2)(f)] Balancing and documentation of the HV AC system shall confonn
to the IMC. Balancing report required to be submitted prior to final occupancy being allowed.
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement fonn SBD-9720 with this office.
Inqniries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
~
Brian Noe
Bnilding Systems Consultant
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
230.00
230.00
0.00
Phm Ko,kws.1'4-4c;..nOÕ-rI
¡¡VAC Only.do"