Loading...
HomeMy WebLinkAbout0116772-HVAC (install) e OSHKOSH ON THE WATER Job Address 1020-1040 W 20TH AVE CITY OF OSHKOSH No 116772 HVAC PERMIT -APPLICATION AND RECORD Owner JAMES PETR Create Date 10/14/2005 Plan P4-46-0705-H Contractor GARTMAN MECHANICAL SERVICES 1"'1 Gas 1 I Oil Fuel System [7] New ~ Forced Air U Radiant 1 1 Electric I 1 HotWater Chimney Type K) Chimney A C) Chimney B Heat Loss K ) As Approved C ) Existing BTU Rate K ) As Per Plan C ) Variable Category 512 -Ind. & Comm-Both 1"'1 Electric 1 1 Solar 1 1 Soiid n Replace U Steam n Other ~NC 1 1 1 Con. Bumer I C) Not Applicable ~ Vent 1 1 Suppl. . DirectVent . NotAppiicable . Other Value Value Use/Nature 1024 - Lindekugel's Saion -Instali HVAC equipment as per plans. of Work $10,930.00 Plan Approval $0.00 Permit Fee Paid $215.00 Fees: Valuation Issued By: Date 10/14/2005 D Permit Voided I Parcelld # 1307110200 In the performance of this work, I agree to perform ali work pursuant to rules goveming the described construction. While tI1e City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in tI1is permit appiication within an easement, the City strongly urges the pennit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date AgenUOwner Address PO BOX 2264 OSHKOSH WI 54903 -2264 Telephone Number (920) 231-5530 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. ~ OJH<OIH City of Oshkosh Division oflnspe<:tion Services 215 Church Avenue PO Box mo Oshkosh WI 54903-1130 www,ci.oshkosh,wi.us ON THE WATER Oct 12, 2005 Keith Paul Gartman Mechanical 520 W Sonth Park Ave Oshkosh WI 54903 James Petr Milwukee P.C. 3900 N Shoreburn Plaza Shorewood WI 53211 Site: Lindekngel's Salon 1024 W 20th Ave Oshkosh WI 54902 For: Description: HV AC system for Tenant space alterations Object Type: HV AC only . Class of Construction: 11m - 2100 Sq Ft.; Unsprinklered Occupancy: B: Business Plan Number: P4-46-0705-H The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code reqnirements Key Item(s) / Conditions: . IMC 302.1 The building or structure shall not be weakened by the installation of mechanical systems. Per letter from Bill Montelbano dated 10/7/05 the structure is adequate for equipment - additional evaluation is requiredfor any screening IMC 403.3 [Comm 64.0403 (6)] Ventilation rate. Janitor closets. A janitor closet that has only one service sink may be provided with either natural ventilation via a window or louvered opening with at least 2 square feet (0.2 m2) of area openable directly to the outside or mechanical exhaust ventilation as specified in Table 64.0403. Per discussion with Keith Paul- additional exhaust will be provided in this area. IFGC 304.2 Appliance/equipment location. Equipment shall be located so as not to interfere with proper circulation of combustion, ventilation, and dilution air. Caution on location of water heater in room with dryer and exhaust grill- [fwater heater is not an electric, or sealed combustion unit additional combustion air may be required. MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. Additionally mc 1608.8 Roofprojections - Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. Per letter from Jim Petrdated 9/2/05 the required screening will be completed by December 31,2005. Plans are required to be submitted and approved prior to installation. Ii '1>11"",,'.200; "",,"..;'.1'4.46.<)70;.[1 '024W IIVACOnly.dü" Page 1 on SUBMIT: IECC 503.3.3.7 [Comm 63.0503(2)(f)] Balancing and documentation of the HV AC system shall confonn to the IMC. Balancing report required to be submitted prior to final occupancy being allowed. . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement fonn SBD-9720 with this office. Inqniries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. ~ Brian Noe Bnilding Systems Consultant (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 230.00 230.00 0.00 Phm Ko,kws.1'4-4c;..nOÕ-rI ¡¡VAC Only.do" Page20f2