Loading...
HomeMy WebLinkAbout0093847 P " e OSHKOSH ON THE WATER Job Address 24712475 PATRIOT LN CITY OF OSHKOSH PLUMBING PERMIT - APPLICATION AND RECORD Contractor WATTERS PLUMBING Owner Category 410 - Residential-Interior Bathtub Whirlpool Lavatory Toilet Res. Sink Bar Sink Water Heater 2 Shower 0 Floor Drain 4 Lndry Tray 4 Lndry Stndp 2 Disposal 0 Dishwasher 2 Sump Pump 0 Classrm Sink 0 Breakrm Sink Site Drain Roof Drain Use/Nature ofWork r~ ~,= 2 2 0 0 2 2 2 0 0 Ejector/Grind 0 Water Softner 0 Local Waste 0 Clothes Wshr 2 Bidet 0 Beer Tap 0 Dent. Oper. 0 Lab Sink 0 Sterilizer 0 Dip Well Drink Ftn Wai!.S!. Ice Chest Exam Sink Sculry Sink Hand Sink Plaster Sink Surgeons Sink 0 0 0 0 0 0 0 0 0 F Prep Sink 0 Serv Sink 0 Shamp Sink 0 FlrlWst Sink 0 Catch Basin 0 Wash Ftn 0 Urinal 0 Standp Rec 0 Ice Maker 0 No 93847 Create Date 04/01/2002 Plan Gar Drain 0 Soda Disp ---.IJ. Coffee Maker 0 Int Grease Trap 0 Ext Grease Trap ---.IJ. Sanitary Sewer Size Storm Sewer Water Service Material Type # Conn. Type Valuation $10,756.00 Issued By \(WI Plan Approval $0.00 Permit Fees 0 0 0 0 0 $156.00 Date 04/25/2002 D Permit Voided I Signature In the perfonnance of this work, i agree to perform ail work pursuant to rules governing the described construction. Address 1303 MIDWAY RD, PO BOX 118 AgenUOwner MENASHA Date Wi 54952 - ~ Telephone Number 800-801-8125,733-81 Fixturê Listiilg Date: November 4, 2002 "-"", Name: WATTERS PLBG Project: duplex Street: Street: 24712475 PATRIOT LN City: City: Non Public Use Fixtures Hot Cold Total I Automatic Clothes Washer 1.00 1.00 1.50 I Dishwashing Machine 1.00 .00 1.00 2 Hose Bib, 1/2" diameter .00 6.00 6.00 I Kitchen Sink 1.00 1.00 1.50 I Bathtub, lavatory and water closet - FT group 2.00 3.50 4.00 2 Shower Stall, lavatory and water closet FT - group 3.00 6.00 7.00 Public Use Fixtures Q Ice Maker Hot .00 I Cold Total .50 I 50 I Total Water Supply Fixture Units 8.00 18.00 21.50 /"-, 14.9 Gallon per minute demand of the building. Predominatly Flush Tank 70.5 Pressure available for uniform loss. For the table use - 71.0 Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 I I 1/4 I 1/2 2 21/2 3 4 Actual!. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 ValueofC 150 150 150 150 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835 /-" J WATER DlSTRIBùTION DATASHEET Date: November 4, 2002 Project: duplex Name: WATTERSPLBG Street: Street: 24712475 PATRIOTLN City: City: I. ~ Gallon per minute buiding demand, predominatly Flush Tank. 2. ~ Low pressure at the Main in the Street. 3. --.J! No water service. 4a.~ No water lateral. 4b.~ No 2nd part water lateral. 5.~ Lb loss from a 3/4in Meter 6. ~ Lbs of pressure available at the Water Meter. This value is entered in (B) below. The (A) value listed below is determined by using the following formula, then rounding the result up. A~ B-(C+~+E) x 100 A. ----1.!. Pressure available for uniform loss (psillOO feet of pipe). ,/""', ; B. ~ Lbs of pressure available at the Water Meter. c. ~ Pressure needed at the controlling fixture. SHWR-MASTER BATH D. ~ Lb loss resulting from a 10.0 II difference in elevation from the Water Meter to the controlling fixture. E. ------.A Lb pressure loss due to a no pressure loss devices serving the controlling fixture. F. ~ Ft Developed length from the 25.0 II actual length of piping from the Water Meter to the controlling fixture. Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 11/4 11/2 2 21/2 3 4 Actual!. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 ValueofC 150 150 150 150 150 150 150 150 150 150 Velocity in II per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835 ~ Fixturê Listing Date: November 4, 2002 Project: duplex Name: WATTERSPLBG Street: Street: 24712475 PATRIOTLN City: City: Non Public Use Fixtures 2 Automatic Clothes Washer 2.00 2.00 3.00 2 Dishwashing Machine 2.00 .00 2.00 4 Hose Bib, 1/2" diameter .00 12.00 12.00 2 Kitchen Sink 2.00 2.00 3.00 2 Bathtub, lavatory and water closet - FT group 4.00 7.00 8.00 2 Shower Stall, lavatory and water closet FT - group 3.00 6.00 7.00 Hot Cold Total Public Use Fixtures Hot .00 I Cold 1.00 I Total 1.00 I CI Ice Maker Total Water Supply Fixture Units 13.00 30.00 36.00 22.4 Gallon per minute demand of the building. Predominatly Flush Tank 99.0 Pressure available for uniform loss. For the table use - 99.0 Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 I I 1/4 I 1/2 2 21/2 3 4 Actual!. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value ofC 150 150 150 150 150 150 150 150 150 150 Velocity in II per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835 ,~ ) WATER DlSTRIBÙTlON DATASHEET Date: November 4, 2002 Name: WATTERSPLBG Project: duplex Street: Street: 24712475 PATRIOT LN City: City: I. ~ Gallon per minute buiding demand, predominatly Flush Tank. 2. ~ Low pressure at the Main in Street. 3. --.J! Lb loss from a:.!! II difference in elevation from Main in Street to the Building Control Valve. 4a.-----.J. Lb loss from a 15.0 II I 1/2" Copper Tube Type K ASTM B88 water service from the Main in Street to the curb stop. Pressure loss deternined using a C value of 150, inside diameter of 1.481 and a velocity of 4.2 II per sec. 4b. 2.6 Lb loss from a 55.0 II I 1/2" PETubingCTS ASTM2737 .AWWAC90lwaterservicefromthecurbstoptotheBuildingControlValve -Pressure loss deternined using a C value of 150, inside diameter of 1.242 and a velocity of 5.91\ per sec. 5.--.J! No water meter. 6. ~ Lbs of pressure available at the Building Control Valve. This value is entered in (B) below. The (A) value listed below is determined by using the following formula, then rounding the result up. A ~ B-(C+~E) x 100 " A. ~ Pressure available for uniform loss (psillOO feet ofpipe). ,/ B. ~ Lbs of pressure available at the Building Control Valve. C. ~ Pressure needed at the controlling fixture. SHWR-MASTER BATH D. ~ Lb loss resulting from a:.!! II difference in elevation from the Building Control Valve to the controlling fixture. E. ------.A Lb pressure loss due to a no pressure loss devices serving the controlling fixture. F. ------.A Ft Developed length from the:.!! 1\ actual length of piping from the Building Control Valve to the controlling fixture. Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 I I 1/4 I 1/2 2 21/2 3 4 Actual!. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value ofC 150 150 150 150 150 150 150 150 150 150 Velocity in II per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835 1\ ) Plumbing Permit Work Card Job Address 2471 2475 PATRIOT LN Permit Number 93847 Create Date 04/01/2002 Owner - Contractor WATTERS PLUMBiNG , Category 410 - ¡¡esidential-Interior Plan Value $10,756.00 Bathtub " 2 Shower 2 Water Softner 0 Wait.St. 0 Shamp Sink 0 Coffee Maker ---.IJ. Whirlpool ---.IJ. Floor Drain ~ Local Waste 0 Ice Chest ---.IJ. FlrlWst Sink 0 Int Grease Trap ---.IJ. Lavatory 4 Lndry Tray 0 Clothes Wshr 2 Exam Sink 0 Catch Basin 0 Ext Grease Trap ---.IJ. Toilet 4 Disposal 2 Bidet 0 Sculry Sink ---.IJ. Wash Ftn ---.IJ. RPZValve ---.IJ. Res. Sink 2 Dishwasher 2 Beer Tap 0 Hand Sink 0 Urinal 0 Eye Wash Statn 0 Bar Sink 0 Sump Pump 2 Lab Sink 0 Plaster Sink ---.IJ. Standp Rec ---.IJ. Wtr Sewer Mtrs 0 Water Heater 2 Classrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0 Deduct Meters 0 Site Drain 0 Breakrm Sink 0 DipWell 0 F Prep Sink 0 Gar Drain 0 Wtr Usage Mirs 0 Roof Drain ---.IJ. Ejector/Grind ---.IJ. Drink Ftn 0 Serv Sink 0 Soda Disp 0 Misc. 0 Fixtures Use/Nature of Work ¡NEW DUPLEX Size Material Type # 0 0 0 0 0 0 0 0 0 0 Conn.Type Sanitary Sewer Storm Sewer Water Service Type Underground 0 0 0 0 0 Inspector WJ (Chip) Callies approved Date 5/1/02 DatelTime requested: Access: Notice Type: Telephone Number: Ready Date/Time: -- Requested By: WATTERS PLUMBiNG 0 Reinspect Fee 0 Fee Waived D Reinspect Fee Paid --- - - - - - - - --- -- - - - - - - - - - ----- - - - - - - - - - - - - - - - - - - - - - - - - - - -- ------------ --- -- - -- ---- - --- -- - --- - - --- - - - --- - -- Job Address 2471 2475 PATRiOT LN Owner Plumbing Permit Work Card Permit Number 93847 Create Date 04/01/2002 Contractor WATTERS PLUMBING Plan Value $10,756.00 Shower 2 Water Softner 0 Wait.St. 0 Shamp Sink 0 ---.IJ. Floor Drain 2 Local Waste 0 Ice Chest ---.IJ. FlrlWst Sink 0 Int Grease Trap ---.IJ. Lndry Tray 0 Clothes Wshr 2 Exam Sink ---.IJ. Catch Basin 0 Ext Grease Trap ---.IJ. Disposal 2 Bidet 0 Sculry Sink 0 Wash Ftn 0 RPZ Valve ---.IJ. Dishwasher 2 BeerTap 0 Hand Sink ---.IJ. 0 ---.IJ. Sump Pump 2 Lab Sink 0 Plaster Sink 0 0 ---.IJ. Classrm Sink 0 Sterilizer 0 Surgeons Sink ---.IJ. 0 ---.IJ. Breakrm Sink 0 DipWell 0 F Prep Sink 0 0 0 Ejector/Grind .............Q Drink FIn 0 Serv Sink ---.IJ. ---.IJ. Urinal Standp Rec Ice Maker Gar Drain Eye Wash Statn Wtr Sewer Mtrs Deduct Meters Wtr Usage Mtrs Category 410 - Residential-interior Bathtub 2 Whirlpool ~ Lavatory ---.i Toilet ---.i Res. Sink 2 Bar Sink ---.IJ. Water Heater ~ Site Drain ---.IJ. Roof Drain ---.IJ. Misc. ---.IJ. Fixtures Use/Nature of Work ¡NEW DUPLEX Size Type # 0 0 0 0 0 0 0 0 0 0 Material Conn.Type Sanitary Sewer Storm Sewer Water Service Type Rough In 0 0 0 0 0 Inspector WJ (Chip) Callies Date 6/13102 approved r~~~ DatelTime requested: 6/11/02 07:31 AM Notice Type: Telephone Number: 733-8125 Access: Ready Datemme: 6/11/02 12:00 PM Requested By: WATTERS PLUMBING - Jamie 0 Reinspect Fee 0 Fee Waived D Reinspect Fee Paid - - -- --- -- --- ----- - - - - ---- - - - - - - - - - - - - - - - - - - - - - ----------------- - - - - - - -- --- - - -- ---- - - - - - - - - - -- -- - - - - -- - - -- Job Address 2471 2475 PATRIOT LN Owner Plumbing Permit Work Card Permit Number 93847 Contractor WATTERS PLUMBING Create Date 04/01/2002 Category 410 - Residentiai-Interior Plan Value $10,756.00 Bathtub ~ Shower 2 Water Softner 0 Wait.St. 0 Shamp Sink ---.IJ. Coffee Maker ---.IJ. Whirlpool ---...!1. Floor Drain ~ Local Waste 0 Ice Chest 0 FlrlWst Sink ---.IJ. Int Grease Trap ---.IJ. Lavatory 4 LndryTray ---.IJ. Clothes Wshr 2 Exam Sink ---.IJ. Catch Basin 0 Ext Grease Trap ---.IJ. Toilet 4 Disposal 2 Bidet 0 Sculry Sink 0 Wash Ftn ---.IJ. RPZValve ---.IJ. Res. Sink ~ Dishwasher ~ BeerTap 0 Hand Sink 0 Urinal ---.IJ. Eye Wash Statn ---.IJ. Bar Sink 0 Sump Pump 2 Lab Sink 0 Plaster Sink ---.IJ. Slandp Rec ---.IJ. Wtr Sewer Mtrs 0 Water Heater ~ Classrm Sink 0 Sterilizer 0 Surgeons Sink ---.IJ. Ice Maker ---.IJ. Deduct Meters ---.IJ. Site Drain ---.IJ. Breakrm Sink 0 Dip Well 0 F Prep Sink ---.IJ. Gar Drain ---.IJ. Wtr Usage Mtrs ---.IJ. Roof Drain 0 Ejector/Grind ---.IJ. Drink Ftn 0 Serv Sink ---.IJ. Soda Disp ---.IJ. Misc. 0 Fixtures ~:~~~~ure ¡NEW DUPLEX Size Material Type # 0 0 0 0 0 Conn.Type Sanitary Sewer Storm Sewer 0 0 0 0 0 0 0 0 0 0 Water Service Date 11/4/02 Type Final Inspector WJ (Chip) Callies approved w/cond. r'~-' ~'_OOTIƒ DatelTime requested: 11/1/02 03:09 PM Notice Type: Telephone Number: 920-733-8125 Access: ~erry F 426-2008 Ready DatelTime: 11/1/02 03:09 PM Requested By: WATTERS PLUMBING-Jamie . Reinspect Fee 0 Fee Waived ~ Reinspect Fee Paid - - --- ------------ - - - - - - - -- - - - - - - -. - - - - - - - - - - - - - ------ -- ------- - - - - - - - - - - - - - - - - - -- - - -. - - _.--.. - - - - -- - - ----