ON THE WATER
Job Address 24712475 PATRIOT LN
CITY OF OSHKOSH
PLUMBING PERMIT - APPLICATION AND RECORD
Contractor WATTERS PLUMBING
Owner
Category 410 - Residential-Interior
Bathtub
Whirlpool
Lavatory
Toilet
Res. Sink
Bar Sink
Water Heater
2 Shower
0 Floor Drain
4 Lndry Tray
4 Lndry Stndp
2 Disposal
0 Dishwasher
2 Sump Pump
0 Classrm Sink
0 Breakrm Sink
Site Drain
Roof Drain
Use/Nature
ofWork
r~ ~,=
2
2
0
0
2
2
2
0
0
Ejector/Grind 0
Water Softner 0
Local Waste 0
Clothes Wshr 2
Bidet 0
Beer Tap 0
Dent. Oper. 0
Lab Sink 0
Sterilizer 0
Dip Well
Drink Ftn
Wai!.S!.
Ice Chest
Exam Sink
Sculry Sink
Hand Sink
Plaster Sink
Surgeons Sink
0
0
0
0
0
0
0
0
0
F Prep Sink 0
Serv Sink 0
Shamp Sink 0
FlrlWst Sink 0
Catch Basin 0
Wash Ftn 0
Urinal 0
Standp Rec 0
Ice Maker 0
No 93847
Create Date 04/01/2002
Plan
Gar Drain 0
Soda Disp ---.IJ.
Coffee Maker 0
Int Grease Trap 0
Ext Grease Trap ---.IJ.
Sanitary Sewer
Size
Storm Sewer
Water Service
Material
Type
#
Conn. Type
Valuation
$10,756.00
Issued By \(WI
Plan Approval
$0.00
Permit Fees
0
0
0
0
0
$156.00
Date 04/25/2002
D Permit Voided I
Signature
In the perfonnance of this work, i agree to perform ail work pursuant to rules governing the described construction.
Address
1303 MIDWAY RD, PO BOX 118
AgenUOwner
MENASHA
Date
Wi 54952 - ~ Telephone Number 800-801-8125,733-81
Fixturê Listiilg
Date: November 4, 2002
"-"",
Name: WATTERS PLBG
Project: duplex
Street:
Street: 24712475 PATRIOT LN
City:
City:
Non Public Use Fixtures
Hot
Cold
Total
I Automatic Clothes Washer 1.00 1.00 1.50
I Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
I Kitchen Sink 1.00 1.00 1.50
I Bathtub, lavatory and water closet - FT group 2.00 3.50 4.00
2 Shower Stall, lavatory and water closet FT - group 3.00 6.00 7.00
Public Use Fixtures
Q Ice Maker
Hot
.00 I
Cold
Total
.50 I
50 I
Total Water Supply Fixture Units
8.00
18.00
21.50
/"-,
14.9 Gallon per minute demand of the building. Predominatly Flush Tank
70.5 Pressure available for uniform loss. For the table use - 71.0
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 I I 1/4 I 1/2 2 21/2 3 4
Actual!. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
ValueofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
/-"
J
WATER DlSTRIBùTION DATASHEET
Date: November 4, 2002
Project: duplex
Name: WATTERSPLBG
Street:
Street: 24712475 PATRIOTLN
City:
City:
I. ~ Gallon per minute buiding demand, predominatly Flush Tank.
2. ~ Low pressure at the Main in the Street.
3. --.J! No water service.
4a.~ No water lateral.
4b.~ No 2nd part water lateral.
5.~ Lb loss from a 3/4in Meter
6. ~ Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
A~ B-(C+~+E) x 100
A. ----1.!. Pressure available for uniform loss (psillOO feet of pipe).
,/""',
;
B. ~ Lbs of pressure available at the Water Meter.
c. ~ Pressure needed at the controlling fixture. SHWR-MASTER BATH
D. ~ Lb loss resulting from a 10.0 II difference in elevation from the Water Meter to the controlling fixture.
E. ------.A Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. ~ Ft Developed length from the 25.0 II actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 11/4 11/2 2 21/2 3 4
Actual!. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
ValueofC 150 150 150 150 150 150 150 150 150 150
Velocity in II per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
~
Fixturê Listing
Date: November 4, 2002
Project: duplex
Name: WATTERSPLBG
Street:
Street: 24712475 PATRIOTLN
City:
City:
Non Public Use Fixtures
2 Automatic Clothes Washer 2.00 2.00 3.00
2 Dishwashing Machine 2.00 .00 2.00
4 Hose Bib, 1/2" diameter .00 12.00 12.00
2 Kitchen Sink 2.00 2.00 3.00
2 Bathtub, lavatory and water closet - FT group 4.00 7.00 8.00
2 Shower Stall, lavatory and water closet FT - group 3.00 6.00 7.00
Hot
Cold
Total
Public Use Fixtures
Hot
.00 I
Cold
1.00 I
Total
1.00 I
CI Ice Maker
Total Water Supply Fixture Units
13.00
30.00
36.00
22.4 Gallon per minute demand of the building. Predominatly Flush Tank
99.0 Pressure available for uniform loss. For the table use - 99.0
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 I I 1/4 I 1/2 2 21/2 3 4
Actual!. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in II per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
,~
)
WATER DlSTRIBÙTlON DATASHEET
Date: November 4, 2002
Name: WATTERSPLBG
Project: duplex
Street:
Street: 24712475 PATRIOT LN
City:
City:
I. ~ Gallon per minute buiding demand, predominatly Flush Tank.
2. ~ Low pressure at the Main in Street.
3. --.J! Lb loss from a:.!! II difference in elevation from Main in Street to the Building Control Valve.
4a.-----.J. Lb loss from a 15.0 II I 1/2" Copper Tube Type K ASTM B88 water service from the Main in Street to the curb stop.
Pressure loss deternined using a C value of 150, inside diameter of 1.481 and a velocity of 4.2 II per sec.
4b. 2.6 Lb loss from a 55.0 II I 1/2" PETubingCTS ASTM2737 .AWWAC90lwaterservicefromthecurbstoptotheBuildingControlValve
-Pressure loss deternined using a C value of 150, inside diameter of 1.242 and a velocity of 5.91\ per sec.
5.--.J! No water meter.
6. ~ Lbs of pressure available at the Building Control Valve. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
A ~ B-(C+~E) x 100
"
A. ~ Pressure available for uniform loss (psillOO feet ofpipe).
,/
B. ~ Lbs of pressure available at the Building Control Valve.
C. ~ Pressure needed at the controlling fixture. SHWR-MASTER BATH
D. ~ Lb loss resulting from a:.!! II difference in elevation from the Building Control Valve to the controlling fixture.
E. ------.A Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. ------.A Ft Developed length from the:.!! 1\ actual length of piping from the Building Control Valve to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 I I 1/4 I 1/2 2 21/2 3 4
Actual!. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in II per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
1\
)
Plumbing Permit Work Card
Job Address 2471 2475 PATRIOT LN Permit Number 93847 Create Date 04/01/2002
Owner - Contractor WATTERS PLUMBiNG
,
Category 410 - ¡¡esidential-Interior Plan Value $10,756.00
Bathtub " 2 Shower 2 Water Softner 0 Wait.St. 0 Shamp Sink 0 Coffee Maker ---.IJ.
Whirlpool ---.IJ. Floor Drain ~ Local Waste 0 Ice Chest ---.IJ. FlrlWst Sink 0 Int Grease Trap ---.IJ.
Lavatory 4 Lndry Tray 0 Clothes Wshr 2 Exam Sink 0 Catch Basin 0 Ext Grease Trap ---.IJ.
Toilet 4 Disposal 2 Bidet 0 Sculry Sink ---.IJ. Wash Ftn ---.IJ. RPZValve ---.IJ.
Res. Sink 2 Dishwasher 2 Beer Tap 0 Hand Sink 0 Urinal 0 Eye Wash Statn 0
Bar Sink 0 Sump Pump 2 Lab Sink 0 Plaster Sink ---.IJ. Standp Rec ---.IJ. Wtr Sewer Mtrs 0
Water Heater 2 Classrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0 Deduct Meters 0
Site Drain 0 Breakrm Sink 0 DipWell 0 F Prep Sink 0 Gar Drain 0 Wtr Usage Mirs 0
Roof Drain ---.IJ. Ejector/Grind ---.IJ. Drink Ftn 0 Serv Sink 0 Soda Disp 0
Misc. 0
Fixtures
Use/Nature
of Work
¡NEW DUPLEX
Size
Material
Type
#
0
0
0
0
0
0
0
0
0
0
Conn.Type
Sanitary Sewer
Storm Sewer
Water Service
Type Underground
0
0
0
0
0
Inspector WJ (Chip) Callies
approved
Date 5/1/02
DatelTime requested:
Access:
Notice Type:
Telephone Number:
Ready Date/Time: -- Requested By: WATTERS PLUMBiNG
0 Reinspect Fee 0 Fee Waived D Reinspect Fee Paid
--- - - - - - - - --- -- - - - - - - - - - ----- - - - - - - - - - - - - - - - - - - - - - - - - - - -- ------------ --- -- - -- ---- - --- -- - --- - - --- - - - --- - --
Job Address 2471 2475 PATRiOT LN
Owner
Plumbing Permit Work Card
Permit Number 93847 Create Date 04/01/2002
Contractor WATTERS PLUMBING
Plan Value $10,756.00
Shower 2 Water Softner 0 Wait.St. 0 Shamp Sink 0 ---.IJ.
Floor Drain 2 Local Waste 0 Ice Chest ---.IJ. FlrlWst Sink 0 Int Grease Trap ---.IJ.
Lndry Tray 0 Clothes Wshr 2 Exam Sink ---.IJ. Catch Basin 0 Ext Grease Trap ---.IJ.
Disposal 2 Bidet 0 Sculry Sink 0 Wash Ftn 0 RPZ Valve ---.IJ.
Dishwasher 2 BeerTap 0 Hand Sink ---.IJ. 0 ---.IJ.
Sump Pump 2 Lab Sink 0 Plaster Sink 0 0 ---.IJ.
Classrm Sink 0 Sterilizer 0 Surgeons Sink ---.IJ. 0 ---.IJ.
Breakrm Sink 0 DipWell 0 F Prep Sink 0 0 0
Ejector/Grind .............Q Drink FIn 0 Serv Sink ---.IJ. ---.IJ.
Urinal
Standp Rec
Ice Maker
Gar Drain
Eye Wash Statn
Wtr Sewer Mtrs
Deduct Meters
Wtr Usage Mtrs
Category 410 - Residential-interior
Bathtub 2
Whirlpool ~
Lavatory ---.i
Toilet ---.i
Res. Sink 2
Bar Sink ---.IJ.
Water Heater ~
Site Drain ---.IJ.
Roof Drain ---.IJ.
Misc. ---.IJ.
Fixtures
Use/Nature
of Work
¡NEW DUPLEX
Size
Type
#
0
0
0
0
0
0
0
0
0
0
Material
Conn.Type
Sanitary Sewer
Storm Sewer
Water Service
Type Rough In
0
0
0
0
0
Inspector WJ (Chip) Callies
Date 6/13102
approved
r~~~
DatelTime requested:
6/11/02 07:31 AM
Notice Type:
Telephone Number:
733-8125
Access:
Ready Datemme: 6/11/02 12:00 PM Requested By: WATTERS PLUMBING - Jamie
0 Reinspect Fee 0 Fee Waived D Reinspect Fee Paid
- - -- --- -- --- ----- - - - - ---- - - - - - - - - - - - - - - - - - - - - - ----------------- - - - - - - -- --- - - -- ---- - - - - - - - - - -- -- - - - - -- - - --
Job Address 2471 2475 PATRIOT LN
Owner
Plumbing Permit Work Card
Permit Number 93847
Contractor WATTERS PLUMBING
Create Date 04/01/2002
Category 410 - Residentiai-Interior Plan Value $10,756.00
Bathtub ~ Shower 2 Water Softner 0 Wait.St. 0 Shamp Sink ---.IJ. Coffee Maker ---.IJ.
Whirlpool ---...!1. Floor Drain ~ Local Waste 0 Ice Chest 0 FlrlWst Sink ---.IJ. Int Grease Trap ---.IJ.
Lavatory 4 LndryTray ---.IJ. Clothes Wshr 2 Exam Sink ---.IJ. Catch Basin 0 Ext Grease Trap ---.IJ.
Toilet 4 Disposal 2 Bidet 0 Sculry Sink 0 Wash Ftn ---.IJ. RPZValve ---.IJ.
Res. Sink ~ Dishwasher ~ BeerTap 0 Hand Sink 0 Urinal ---.IJ. Eye Wash Statn ---.IJ.
Bar Sink 0 Sump Pump 2 Lab Sink 0 Plaster Sink ---.IJ. Slandp Rec ---.IJ. Wtr Sewer Mtrs 0
Water Heater ~ Classrm Sink 0 Sterilizer 0 Surgeons Sink ---.IJ. Ice Maker ---.IJ. Deduct Meters ---.IJ.
Site Drain ---.IJ. Breakrm Sink 0 Dip Well 0 F Prep Sink ---.IJ. Gar Drain ---.IJ. Wtr Usage Mtrs ---.IJ.
Roof Drain 0 Ejector/Grind ---.IJ. Drink Ftn 0 Serv Sink ---.IJ. Soda Disp ---.IJ.
Misc. 0
Fixtures
~:~~~~ure ¡NEW DUPLEX
Size
Material
Type
#
0
0
0
0
0
Conn.Type
Sanitary Sewer
Storm Sewer
0
0
0
0
0
0
0
0
0
0
Water Service
Date 11/4/02
Type Final
Inspector WJ (Chip) Callies
approved w/cond.
r'~-'
~'_OOTIĆ
DatelTime requested: 11/1/02
03:09 PM
Notice Type:
Telephone Number:
920-733-8125
Access:
~erry F 426-2008
Ready DatelTime: 11/1/02 03:09 PM Requested By: WATTERS PLUMBING-Jamie
. Reinspect Fee 0 Fee Waived ~ Reinspect Fee Paid
- - --- ------------ - - - - - - - -- - - - - - - -. - - - - - - - - - - - - - ------ -- ------- - - - - - - - - - - - - - - - - - -- - - -. - - _.--.. - - - - -- - - ----