HomeMy WebLinkAbout10522 (10/5/05)-Housing violations
~'
OSHKOSH
ON THE WATER
Issue Date 10/5/05 -
Address 667 BOWEN ST
Senllo
Introduction
Item #
Description
10/5/05
Last
Updated
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 11/4/05
Compliance No
l"'i Owner
Name
I STEVEN F/ROSE M FAUST
Address
204 WYLDE BERRY LN
City
OSHKOSH
State Zip Code
WI 54904 -0000
---
U Required for Occupancy I Occupancy Two Family
n inspection of your rental property (living unit) following a tenant complaint revealed the following violations of the Oshkosh
Minimum Housing Code which shall be corrected by the compliance dates specified for each item. See enclosed photos for
locations and specifics on violations noted. All vioiations may not have been photographed.
Code 16-33A(6) Compliance No Compliance Date 11/04/2005
tairways in one and two family dwellings shall be in sound condition, equipped with proper handrails & guardrails installed in
ccordance with COMM 21.04 , safe to use and shall be equipped with treads and risers reasonably unifomn. Handraiis or
uardrails shall be provided on all open sides of stairs consisting of more than 3 risers.
Item # Code 16-35A(1)b Compliance No Compliance Date ~~
Description II rainwater shall be so drained from the roof/ground so as not to allow dampness inside the dwelling unit and so drained as
not to allow standing water, water damage or other detrimental conditions in the dwelling.
10/5/05
Last
Updated
Item # Code 16-35A(1)a Compliance No Compliance Date 11/04/2005
Description Every floor, floor covering, wall, ceiling, kitchen counters & tops, cupboards & exterior doors etc shall be kept in good repair.
10/5/05
Last
Updated
Item # 4 Code 16-34A(3)a Compliance No Compliance Date ~-
Description Every outlet and fixture shall be properly installed and shall be maintained in a good and safe working condition and shall be
onnected to the source of the electric power in a safe manner. All living units shall be provided with safe and adequate
10/5/05 lectricai facilities, fixtures & wiring.
Last
Updated
Item # 5 Code 16-37A(1) Compliance No Compliance Date ~-
Description Every owner of two or more family dwelling units shall be responsibie for maintaining in a safe, clean, good & code compliant
ondition inside & out all communal, shared or public areas of the dwelling and appurtenant premises.
10/5/05
Last
Updated
Item #
Description
10/5/05
Last
Updated
Code 7-43 Compliance No Compliance Date ~-
Before commencing construction, installation, erecting, aiteration or remodeling of any heating, ventilating, or air conditioning
~ystem, a permit shall first be secured from the Heating Inspector by the owner or his agent, and it shall be unlawful to
Fommence any such work unless such permit shall have first been obtained, except as otherwise provided herein. No permit
pn file for the furnace installation.
10522
Page 1 of3
~
OSHKOSH
ON THE WATER
IssueDate 10/5/05 - Compliance Date 11/4/05
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance No
Address
667 BOWEN ST
Sent to
l"'i Owner
Name
I STEVEN F/ROSE M FAUST
Address
204 WYLDE BERRY LN
City
OSHKOSH
State Zip Code
WI 54904 -0000
---
U Required for Occupancy I Occupancy Two Family
Introduction
!l'n inspection of your rental property (living unit) following a tenant complaint revealed the following vioiations of the Oshkosh
Minimum Housing Code which shall be corrected by the compliance dates specified for each item. See enclosed photos for
locations and specifics on violations noted. All violations may not have been photographed.
Item # 7 Code 20-8A Compliance No Compliance Date 11/04/2005
Description Installation of plumbing in rental dwellings requires a licensed plumber and a plumbing permit. No permit on file for this work.
(Water heaters)@@
10/5/05
Last
Updated
Item # Code 16-33A(9)a Compliance No Compliance Date 11/04/2005
Description All living unit entryways shall be equipped with solid core doors in good condition and deadbolt locks installed as defined in
Section 16-22 OMC.
10/5/05
Last
Updated
Item #
Code 11-44 Compliance No Compliance Date 11/04/2005
When electrical equipment is found to be to be unsafe or dangerous to persons or property, the person owning or using such
equipment shall remove or cause to be removed or make any changes or repairs determined by the Electrical Inspector.
Failure to comply can result is the disconnection of the electrical service. See enclosed photos for locations and specifics on
iolations noted. (Electrical main to meters)
Description
10/5/05
Last
Updated
Item #
10
Code 17-36A Compliance No Compliance Date 11/04/2005
he exterior of every structure or accessory structure (garage or shed) shall be maintained by the owner in good repair and all
xterior surfaces thereof be kept painted or covered with exterior siding for purposes of preservation and appearance. All
uilding foundations shall be maintained in good repair. See enclosed photos for locations and specifics on violations noted.
II violations may not have been photographed.
Description
10/5/05
Last
Updated
Item #
11
Code 17-36D Compliance No Compliance Date ~-
II openings where rodents, pigeons, insects might enter shall be properly and effectively sealed.@@
~
Description
10/5/05
Last
Updated
10522
Page 2 of3
.~
OSHKOSH
ON THE WATER
Issue Date 10/5/05 Compliance Date 11/4/05
--
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance No
Address
667 BOWEN ST
Senllo
l"'i Owner
Name
I STEVEN F/ROSE M FAUST
Address
204 WYLDE BERRY LN
City
OSHKOSH
State Zip Code
WI 54904 -0000
---
Introduction
U Required for Occupancy I Occupancy Two Family
n inspection of your rental property (living unit) following a tenant complaint revealed the following violations of the Oshkosh
Minimum Housing Code which shall be corrected by the compliance dates specified for each item. See enclosed photos for
locations and specifics on violations noted. All violations may not have been photographed.
Item # 12 Code 16-35A(6) Compliance No Compliance Date 11/04/2005
Description No owner or operator shall rent to any other person for occupancy or allow any person to occupy any dwelling unit or premises
nless it is safe and clean and complies with all provisions of the Minimum Housing Code and Property Maintenance Code.
10/5/05
Last
Updated
Summarv
It is the responsibility of every property owner to confimn compliance with these orders before the compliance date as specified
nd return the signed confirmation. Please contact this office on or before the scheduled due date.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 11/4/05
Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1:3D p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the
nature of what needs to be inspected.
Signature
Date
Inspected by: Kenneth Gresser 236-5137 kgresser@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name
Signature
Also Sent to: U Bldg I
U Elec I
U HVAC I
U Pibg I
U Designer I
U Other I OCCUPANTS
l"'i inspector I John Zarate
Company
Date
---
---
---
---
---
667 BOWEN ST
OSHKOSH
WI 54901 -0000
---
10522
Page30f3
Taken by Kenneth Gresser
667 bowen.doc1
Violation(s) of 16-33A(6)
Taken by Kenneth Gresser
667 bowen.doc2
Violation(s) of 16-33A(6)
Taken by Kenneth Gresser
667 bowen.doc3
Violation(s) of 16-35A(1)b
Taken by Kenneth Gresser
667 bowen.doc4
Violation(s) of 16-35A(1)b & 16-35A(1)a
Taken by Kenneth Gresser
667 bowen.doc5
Violation(s) of 16-35A(1)a & 16-34A(3)a
Taken by Kenneth Gresser
667 bowen.doc6
Violation(s) of 16-35A(1)b & 16-37A(1)
Taken by Kenneth Gresser
667 bowen.doc7
Violation(s) of 16-35A(1)b & 16-37A(1)
Taken by Kenneth Gresser
667 bowen.doc8
Violation(s) of 16-35A(1)b & 16-37A(1)
Taken by Kenneth Gresser
667 bowen.doc9
Violation(s) of 16-33A(6)
Taken by Kenneth Gresser
667 bowen.doc10
Violation(s) of 7-43
Taken by Kenneth Gresser
667 bowen.doc11
Violation(s) of 7-43
Taken by Kenneth Gresser
667 bowen.doc12
Violation(s) of 20-8A
Taken by Kenneth Gresser
667 bowen.doc13
Violation(s) of 16-33A(9)a
Taken by Kenneth Gresser
667 bowen.doc14
Violation(s) of 11-44
Taken by Kenneth Gresser
667 bowen.doc15
Violation(s) of 17-36A & 17-36D
Taken by Kenneth Gresser
667 bowen.doc16
Violation(s) of 17-36A
Taken by Kenneth Gresser
667 bowen.doc17
Violation(s) of 17-36A
Taken by Kenneth Gresser
667 bowen.doc18