HomeMy WebLinkAbout0116193-Building
e
OSHKOSH
ON THE WATER
Job Address 3190 OLD ORCHARD LN
CITY OF OSHKOSH
No
116193
BUILDING PERMIT - APPLICATION AND RECORD
Owner MARK H/KRISTEN LASKY
Create Date
09/07/2005
D,esigner
Contractor
CR MEYER
Category
111 - Single Family Addition
Plan
1'¡þe
. Building
0 Sign
0 Canopy
0 Fence
0 Raze
Zoning
Class of Const: VB
Size
Unfinished/Basement
~Sq.Ft.
~ Sq. Ft.
Rooms
0
Height 0 Ft.
D Projection I
Finished/Living
Bedrooms
Stories 2
Canopies 0
Garage
~Sq.Ft.
Baths
Signs
~
Foundation
. Poured Concrete 0 Floating Slab
0 Concrete Block 0 Post
0 Pier
0 Treated Wood
0 Other
Occuþancy Permit Required
Flood Plain No
Height Permit Not Required
Not Required
# Dwelling Units -----.!!
# Structures
0
Park Dedication
Use/Nature SFRI construct 2 story addition 178 sq It 1st floor, 226 sq It 2nd floor. add a dormer, and reshingle the enjjre home, as per plans
of Work ubmitted. - Provide structural cales for beams prior to rough inspections.
HVAC Contractor
"
UNKNOWN???
SECKAR ELECTRIC CO INC
Plumbing Contractor
DR HANSEN PLBG.
Electric Contractor
$103.078.00 Plan Approval
$75.00 Permit Fee Paid
$376.00 Park Dedication
$0.00
Fees: Valuation
Issued By:
Date 09/08/2005
Final/O.P. 00/00/0000
D Permit Voided I
Parcelld # 1417480000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party. if you perform the work
described in this permit application within a ent. the City strongly urges the permit applicant to contact the easement
holder(s) and to see sary IS b fore starting such activity. " I~
Signature Date C\. ~ \Ç:j-Z;;-
\
AgenUOwner
Address 895 W 20TH AVE
OSHKOSH
~ 54902 - 0000 Telephone Number
920-235-3350 x219
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
PLAN SUBMITTAL CHECKLIST
For Additions to 1& 2 Family Homes
**AIl drawings must be legible and drawn to scale and dimensioned to include:
Please Note; Missing or incomplete information may delay Plan Approval and Permit Issuance.
I. Buildin~ oermit aoolicatioo/information sheet (located in the ápplication & form section)
"Eiur Use ¿rce Use
"8
~
~
'-EJ
'-@
3.
"'u D
~ D
"i!J D
"0 D
"0 D
"El D
~ D
~ D
"g D
~ D
~ D
-.¡;¡] D
4.
~ D
D
èf D
2. Plot ulan/Site ulan indicatin~:
The location and size of:
D Proposed addition including all exterior dimensions
D All buildings including 'my existing structures
D Accessory structures
D Driveways, patios, decks, fences, and pools
D Storm drainage grades and drainage features - For sites/subdivisions subject to an adopted
storm drainage plan and grading.
NOTE: All setbacks must be clearly labeled 00 the site plan.. It is suggested site plans be
drawn on City GIS site plans which can be obtaioed from the Planning Services
Department located on 20' floor, RM 204.
Floor ulan. indicatin~: (two copies)
The size and location of:
Rooms
Doors
Room use (kitchen, dining, family, bedroom, etc.)
Smoke detectors
Windows
Structural features- size, species and grade of lumber and other structural
materials used for joists, b~ams, ra~s, trusses, headers, studs, and columns.
NO~ calcUl~~equ¡red for any beams with point loads on them.
Exit passageways (hallways) and stairwells
Plumbing fixtures (bathroom, kitchen, etc.)- lavatory, water closet, water heater,
softener, etc.
Chinmey(s)- incl,;,de also the type of construction (masonry òr factory built) and
rating, if metal.
Heating equipment
Attic and crawl space access
Fire separation between dwelling and garage
Truss Dlan. includin~: (these must be submitted and approved PRIOR to the rough
framing inspection)
A truss layout drawing indicating how the trusses will be installed.
A truss design plan for each .truss with all information required by TPI. This information
may be provided at the rough framing inspection. -
Connection details for all truss / framing connections
I CERTIFY THE ABOVE INFORMATION IS COMPLETE. ANY MISSING
INFORMATION MAY DELAY PLA OVAL. below)
APPLICANTS SIGNA
5.
~ 0
"0 0
~ 0
"0 0
"@ 0
~ 0
0
~ O.
0'
0 0
~ 6.
0
0
'EJ 0
7.
"'EJ 0
"0 0
'0. 0
~ 0
0
"'0 0
"'0 8.
0
Foundation Glans indicatiu~: (two copies)
The size and location of:
Structural features- strength, thickness, and reinforcement (if any) of concrete for footings,
foundations, floors ànd any other concrete work; height and thiêkness of concrete and/or
masonry construction
Footings
Column pads -:- Calculate size of pad carrying the most load.
Wall construction
Beams
All dimensions
Plumbing fixtures
Service panel
Sump pit
Furnace
Elevation Glans indicatin~: (two copies)
Dwelling height
Information on exterior appearance
Indicate the location, size and configuration of doors,windows, roof,.chimneys and exterior
grade level
Cross-sectional dráwin~ indicatin~: (two copies) (there Is a cross section enclosed for your
convenience)
Exterior fmish grade level.
Footing and foundation wall sizes, drain tile system and type of materials (Must be sized to
carry anticipated loads- NOT just minimum code req.)
Exterior wall construction identifying materials used (including insulation, vapor barrier,
wall sheathing, stud spacing)
Stair dimensions- riser heighJs, tread widths, headroom, handrail and guardrail heights
Roof construction identifying type of material, size, and spans (including insulation, vapor
barrier, roof sheathmg, and rafter/truss.spacing)
Floor construction Identifying type of material, size, and spans (including insulation)
Heat loss calculations (these are provided by your lumber supplier or heating.contractor)
Accurate information, correct square footage, and insulation,values
DATE:
\:)~
PROJECT ADDRESS:
'::>\"\>;;) ~\'(:::, ~Çl'¡,¡>/\þ,~ \.þ.;-\'.;;.
~~~\-, \~
ZONING/LAND USE COMPLIANCE CHECKLIST
JOB LOCATION: 3190 Old Orchard Rd (14-1748-0000)
ZONING: R-1
PROPERTY OWNER/CONTRACTOR: Daniel Patrick Lynch. Applicant (920-235-3350)
CONSTRUCTION DATA: 0 New Construction
!81 Addition
0 Alteration
TYPE OF CONSTRUCTION: (i.e. fence, pool, parking lot, sign, etc.) Residential addition.
COMPLIANCE CHECKLIST
DEFICIENT
0 Use
0 Lot Width
0 Lot Area
0 Lot Area Per Family
0 Floodplain
0 Front Yard
0 Front Yard Side Street
DEFICIENT
0 RearYard
0 Side Yards
0 Building Area
0 Parking Standards
0 Off-Street Loading Standards
0 Vision Clearance
0 Transitional Yard Standards
0 Parking Lot Lighting
COMMENTS:
DEFICIENT
0 Landscape Standards
0 Height
0 Conditions of Approval
0 Compliance with P.C. or
BZA Conditions of Approval
0 Signage Standards
0 Mechanical Equip. Screening
0 Other
If you have any questions or concerns regarding this review checklist or the requested
information, please do not hesitate to contact me at by phone at 920.236.5062 or bye-mail at
dbucka'ì>.cLoshkosh.wi.us.
REVIEW AUTHORITY
As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approve all plans, except the
following; (1) AI/erations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows,
etc., when the use is conforming and when no change is proposed.
APPROVED L
HOLD
Plan Commission Action Required
BOAIVariance(s) Required
REVIEWED BY: David Buck
DENIED
DATE: 08/30/05
AJðI'-'-S';>
p"c..f'-
1"0\',,\
~