Loading...
HomeMy WebLinkAbout2005-HVAC Q1-67-0805 >. ~ OJHKOJH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wí.us O"HE WA"" September 7, 2005 Arthur Warren Condon Total Comfort, Inc. II Blackburn Street Ripon WI 54971 Arthur Pommerening Pommerening Dodge 237 N Washburn St Oshkosh, WI 54904 Site: Pommerening Dodge 237 N Washburn St Oshkosh WI 54904 For: Description: HV AC alterations - Existing building only Object Type: HV AC only Class of Construction: IIB - 1906 Sq Ft.; Unsprinklered Occupancy: B: Business I Office Plan Number: Q1-67-0805 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as deemed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: . IMC 302.1 The building or structure shall not be weakened by the installation of mechanical systems. Verify that existing structure is capable of supporting the additional weight of the proposed rooftop equipment. IMC 304.1 Equipment and appliances shall be installed as required by the terms of their approval, in accordance with the conditions of the listing, the manufactures instructions and this code. IMC 304.9 Guards. Guards shall be provided where appliances, equipment, fans or other components that require service are located within 10 feet (3048 mm) of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches (762 mm) above the floor, roof or grade below. The guard shall extend not less than 30 inches (762 mm) beyond each end of such appliance, equipment, fan or component and the top of the guard shall be located not less than 42 inches (1067 mm) above the elevated surface adjacent to the guard. The guard shall be constructed so as to prevent the passage of a 21-inch- diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code IMC 306.5 Equipment and appliances on roofs or elevated structures. Where equipment and appliances requiring access are installed on roofs or elevated structures at a height exceeding 16 feet (4877 mm), such access shall be provided by a permanent approved means of access, the extent of which shall be from grade or floor level to the equipment and appliances' level service space. Such access shall not require climbing over obstructions greater than 30 inches (762 mm) high or walking on roofs having a slope greater than 4 units vertical in 12 units horizontal (33-percent slope). \.üSHKOSHMISFS\USERS\bri"nn'2005 Comm P¡ön Ronew,\QI-(i7-œO; 237 N Wwhbum $t HVAC '.m!y.doo Page 1 of2 IMC 401.5.1 Mechanical and gravity outside air intake openings shall be located a minimum of 10 feet ITom any hazardous or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks. IFGC 401/Comm 65.0400 All gas piping and gas piping installations shall comply with NFP A 54, National Fuel Gas Code. Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm61.3I(1). MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. Additionally mc 1608.8 Roofprojections - Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be detennined in accordance with Section 7.8 of ASCE 7. No permit wül he issued until screening plan is provided. SUBMIT: IECC 503.3.3.7 [Comm 63.0503(2)(1)] Balancing and documentation of the HV AC system shall conform to the lMC. Balancing report required to be submitted prior to final occupancy being allowed. . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise makiug them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the nwnber listed below or the address on this letterhead. .Re~, í?& Building Systems Inspector. (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 230.00 230.00 0.00 ...\OSTH<OSHMISFS\USERS\briwm'2005 Comm PI'TI Re,iew,\QI-67-0805 237 N Wwhbom St IIVAC only.doc Page2of2