HomeMy WebLinkAbout2005-HVAC (kitchen hood) ~ OSHKOSH ON THE WATER Job Address 430 N MAIN ST CITY OF OSHKOSH No 116088 HVAC PERMIT -APPLICATION AND RECORD Owner JFS ENTERPRISES LLC Create Date 09/0212005 Plan P9-62-0805 Contractor FOX VALLEY CLEAN AIR I 1 Gas [7] New Category 510 -Ind. & Comm-Heating & Ventiiating Fuel I 1 Soiar 1 1 Solid 1 1 Oil 1,(1 Eiectric n Replace U Forced Air 1 I Electric D Other U AlC 1 ~ Vent 1 I Con. Bumer 1 . NotApplicabie System U Radiant 1 I Hot Water U Steam I I Suppl. Chimney Type K) Chimney A Heat Loss r ) As Approved K ) As Per Plan ( ) Chimney B () Existing () DirectVent BTU Rate ( ) Variable . NotApplicabie . Other Value Value Use/Nature Instali new kitchen hood exhaust system as per pian. olWork Fees: Valuation $12.000.00 Plan Approval $0.00 Permit Fee Paid $175.00 Issued By: Date 09/0212005 D PenmitVoided I Parcelld # 0400870000 In the perfonmance 01 this work, I agree to perfonm ali work pursuant to rules governing the described construction. While the City 01 Oshkosh has no authority to enforce easement restrictions 01 which it is not a party. ilyou perform the work described in this penmit application within an easement, the City strongiy urges the penmit applicant to contact the easement hoider(s) and to secure any necessary approvals belore starting such activity. Signature Date Agent/Owner Address 1020 AMERICAN DR NEENAH WI 54958-0 Telephone Number 886-9797 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project Is ready. CtJ OfHKOIH City 01 Oshkosh Division 01 Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wi.us Sept 2, 2005 ON THE WATER Paul Sobieck Milwaukee Stove & Furnace 2442 Hutson Road Green Bay WI 54303 Joe Steinike 430 N Main St Oshkosh WI 54901 Plan Nnmber: P9-62-0805 Site: Joe's Sample House 430NMainSt Oshkosh WI 54901 For: Description: Kitchen Hood Installation Object Type: HV AC - HOOD only Class of Construction: VB- Unsprinklered The submittal described above has been reviewed for confonnance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: . mc 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems are required to be provided at the time of inspection. 1M C 302.1 The building or structure shall not be weakened by the installation of mechanical systems. Verify that existing structure is capable ofsupporling the additional weight of the proposed rooftop equipment / exhaust hood assembly. IMC 306.5 Equipment and appliances on roofs or elevated structures. Where equipment and appliances requiring access are installed on roofs or elevated structures at a height exceeding 16 feet (4877 mID), such access shall be provided by a permanent approved means of access, the extent of which shall be from grade or floor level to the equipment and appliances' level service space. Such access shall not require climbing over obstructions greater than 30 inches (762 mID) high or walking on roofs having a slope greater than 4 units vertical in 12 units horizontal (33-percent slope). IMC 401.5 Opening Location Outside air exhaust and intake openings shall be located a minimum of 10 feet (3048 mID) from lot lines or buildings on the same lot. Where opeuings front on a street or public way, the distance shall be measured to the centerline of the street or public way. IMC 401.5.1 Mechanical and gravity outside air intake openings shall be located a minimum of 10 feet from any hazardous or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks. rhb,iann'ZO()5 Comm Plan Reviews\P9.62.0805 430 N M.ain St IIood Only.doc Page 1 of2 . IMC 507.6 Type I hoods are required to secured in place by noncombustible supports. As discussed non-combustible supports will be used. IMC 507.9 A type I hood shall be installed with a clearance to combustibles of not less than 18 inches. Exception: Clearance shall not be required from gypsum wallboard attached to noncombustible structures provided that a smooth, cleanable, nonabsorbent and noncombustible material is installed between the hood an the gypsum wall-board over an area extending not less than 18 inches in all directions from the hood. As discussed a wall constructed of steel studs with gypsum board and stainless steel covering will be installed behind the hood. IMC 509.1 An approved automatic fire suppression system complying with the mc and IFC is required for this hood installation. Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm61.31(1). MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened from view of any street or residential zoning district. Contact David Buck Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. If after installation of equipment is visible from street or residential area screening may be required. . . SUBMIT: IECC 503.3.3.7 [Comm 63.0503(2)(1)J Balancing and documentation ofthe HV AC system shall conform to the IMC. Balancing report required to be submitted prior to final occupancy being allowed. . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. R~, ~~ Building Systems Inspector. (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30A.M and 12:30 A.M to 1:30 P.M. bnoe@cLoshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 230.00 230.00 0.00 ¡¡,'.bmmn'2005 Comm PI"" Revlev,,'P9-62.( g05 430 N Mal" St IT<",I O"ly.doc Page 2 of2