HomeMy WebLinkAbout0116093-Building
e
OSHKOSH
ON THE WATER
Job Address 300 S KOELLER ST
CITY OF OSHKOSH
BUILDING PERMIT - APPLICATION AND RECORD
No
116093
OWner LANDMARK LIMITED PARTNERSHIP III
Create Date
08/26/2005
Designer
Rick Fisher
Contractor
R J ALBRIGHT INC.
Category
232 - Alteration Stores & Customer Service
Plan
Type
. Building
0 Sign
0 Canopy
0 Fence
0 Raze
Zoning
Class of Const:
Size
Unfinished/Basement ~Sq.Ft. Rooms
Finished/Living ~Sq.Ft. Bedrooms 0
Garage ~Sq.Ft. Baths 0
Height
0 Ft.
D Projection I
Stories ~
Canopies ~
Signs
0
Foundation
. Poured Concrete 0 Floating Slab
0 Concrete Block 0 Post
0 Pier
0 Treated Wood
0 Other
Occupancy Penmit Required
Flood Plain
Height Permit
Park Dedication
# Dwelling Units ~
# Structures
0
Use/Nature
of Work
Tenant alterations at SE corner of building for Kirby Vacuum. . Late Penmi!.
HVAC Contractor
Plumbing Contractor
Electric Contractor
Fees: Valuation
$32,000.00 Plan Approval
$0.00 Permit Fee Paid
$320.00 Park Dedication
$0.00
Issued By:
Date 09/0212005
Final/O,P, 00/00/0000
D Permit Voided I
Parcelld # 0608770000
In the perfonmance of this work I agree to perfonm all work pursuant to rules governin9 the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perfonm the work
described in this permit application within an easement, the City trongly urges the penmit applicant to contact the easement
:~~:e:::~ndt~sSarya al b res rti such activity. Date ~-g-Q5
Address 5711 GREEN VALLEY RD
Wi 54904 - 0000 Telephone Number
231-8635
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready,
~
OIH<OIH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Bnx 1130
Oshkosh WI 54903-1130
www.ci.oshkosh.wi.us
ON 'HE WA'"
August 30, 2005
Richard Fischer
Fisher & Associates"LLC
642 Thlosen Drive
KllnberlyWI54136
Ron Degen
Landmark L TD III
PO Box 2366
Oshkosh WI 54903
Site:
Landmark Plaza
300 S Koeller Road Suite "K" Kirby V acnwn Sales
Oshkosh WI 54902
For:
Description: Tenant space alterations
Object Type: Building only
Class ofConstrnction: lIB - 2480 Sq Ft.; Sprinklered
Occupancy: B: Business Office
Max Number of Occnpants 32
Plan Number: P9-63-0805
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner. as defined in Chapter
101.01(10), Wisconsin Statntes, is responsible for compliance with all code requirements
Key Item(s) I Conditions:
.
mc 505.2 Area limitation. The aggregate area of a mezzanine or mezzanines within a room shall not
exceed one-third of the area of that room or space in which they are located. The enclosed portions of
rooms shall not be included in a determination of the size of the room in which the mezzanine is located.
In determining the allowable mezzanine area, the area of the mezzanine shall not be included in the area of
the room. Per discussion with Rick Fischer 8ßO/O5 the area indicated on plans as a mezzanine will be
considered as a 2'" story. In discussion with Henry Kosarzycki with Department of Commerce, the area
limitations are not required to be considered, and no fire barrier is requires to separate this space, as .
the volume of the building is not being increased, and was approved under earlier versions of code with
an unlimited area.
mc 71 1.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping
system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems
are required to be provided at the time of inspection,
IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with
this code and the international fire code, (Construction of new walls may require the addition and or
relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire
sprinklers)
\\OSHKOSHMISFS\USFRS\bnæm',2005 Comm PI"" Ro,iow,\P9~;3-ú8ú5 ,00 S KoolI" St BJdg Only.doc
Page lof3
IFC 901.4 Fire protection systems shall be maintained in accordance with the original installation
standards for that system. Required fire protection systems shall be extended, altered, or augmented as
necessary to maintain and continue protection whenever the building is altered, remodeled or added to,
Alterations to fire protection systems shall be done in accordance with applicable standards. Submit plans
for fire sprinkler modifications.
mc 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
!BC 1003,2.10 Exit signs are required to be installed per this section
IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
are required to have adequate emergency lighting to meet the performance requirements of mc
1003.2.11.3. Existing means of egress emergency lighting is permitted to be maintained in compliance
with the code in effect at the time of construction. Any altered path of egress, or new path of egress,
and any new emergency lighting being installed is required to comply with current code requirements.
!BC 1005.3.2 Exceptions:I. In other than Groups H and I occupancies, a stairway serving an occupant
load ofless than 10 not more than one story above the level of exit discharge is not required to be enclosed.
Per discussion with Rick Fischer on MO/O5, the occupant load will be less thall10, so rated stair
enclosure is not required.
mc 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6
inches up onto walls.
mc 2902..1/ Table 2902 Drinking water is required to be provided, since no drinking fountain is shown
on plans a bottled water cooler is required to be provided.
Comm 61.30(3) This review does not include lighting. Cornm 63.0001 Prior to installation, lighting
plans and calculations shall be prepared in compliance with the code. The plans shall be available upon
request.
Comm 6130(3) / IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC
equipment. Be aware that mc 1004.3,2.4 contains additional restriction for air movement in corridors
Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Cornm 61.31(1).
SUBMIT:
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
','OSHKOSJ [MJSFS\USERS\briann'2005 Comm Plan Re\iews',P9.63.0805 300 S Koeliç, St Hldg Only. doc
Page 2 00
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pennits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state staIB 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning'this correspondence may be made to me at the number listed below or the address on this letterhead.
~
Building Systems Inspector.
(920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
320.00
320.00
0.00
'.'ÐSTIKOSTIMISFS\USERS\b,iann'2005 Comm Phm R,vi,w,\P9~;3-œ05 300 S Ko,I1<, SI Hldg Only.doç
Page 3 on
Job Address 300 S KOELLER ST
Building Permit Work Card
Permit Number 0116093 Create Date 8/26/05
OWner LANDMARK LIMITED PARTNERSHIP Iii
Contractor R J ALBRIGHT INC.
Category 232 - Aiteratlon Stores & Customer Service
Type. Building
0 Sign
0 Canopy
0 Fence
0 Raze
I Plan
Value
Zoning
Class of Canst:
Size
$32,000.00
Unfinished/Basement ~ ~~. Finished/Living ~ Sq. Ft. Garage ~ Sq. Ft.
Rooms ~ Bedrooms ----..2 Baths ~ D Projection I
Stories ~ -~ Height ~ Ft. Canopies ~ Signs 0
Foundation. Poured Concrete
0 Con~rete Block
0 Fioating Slab
0 Post
0 Pier
0 Treated Wood
0 Other
Occupany Permit Required
Park Dedication
Flood Plain
Height Penmit
# Dwelling Units ~
# Structures
0
Use/Nature
of Work
Tenant alterations at SE comer of building for Kirby Vacuum. . Late Permit.
HVAC Contr
Plumbing Contr
Electric Contr
Inspections:
Date 9/23/05 --'---
Type Final
Inspector Allyn Dannhoff
not approved
C/N ON MECHANICAL SCREEN / COMPLIANCE STATEMENTS
NOTE: 2ND FLOOR LIMITED TO 10 OCCUPANTS
DatelTime requested:
Access:
--
Notice Type:
Phone Number:
Ready DatelTime: ~--=------- Requested By:
0 Reinspect Fee 0 Fee Waived
D Reinspect Fee Paid
- - - - - --- - - - - - - - - - - - - - --- -- - - - - - -- - - - - - -- - - - --------- -- -- - - - - - - - - - - - - ---- - - - - - - - - - - - - - --- -----
Date 11/3/05 --'---
Type Final
Inspector Allyn Dannhoff
approved w/cond.
NOTE: OCCUPANCY OK. NOTE ON C.O.-REQUIRED MECHANICAL SCREENING SHALL BE INSTALLED BY 6/1/07.
DatelTime requested:
Access:
-
Notice Type:
Phone Number:
Ready DatelTime: ~--=------- Requested By:
0 Reinspect Fee 0 Fee Waived
D Reinspect Fee Paid
--- - - - - - - --- --- - - - - - - - - - - - - -- - - - - -- - - - - - - -- - - - - - - - - - - - - - - -- ------- -- - - - - - - ------- --- - - - - - - - --