Job Address 2380 STATE ROAD 44
CITY OF OSHKOSH
HVAC PERMIT -APPLICATION AND RECORD
No
115631
Owner
HWY 44 BUSINESS PLACE LLC
Create Date 08/05/2005
Plan L5-29-0405
Contractor SURE-FIRE INC
1,(1 Gas I I Oil
Fuel
System 0 New
~ Forced Air U Radiant
I I Electric I I Hot Water
Chimney Type K) Chimney A C) Chimney B
Heat Loss K ) As Approved C ) Existing
BTU Rate K) As Per Plan C ) Variable
Category 512 -Ind. & Comm-Both
1,(1 Electric
I I Solar
I I Solid
0 Replace
U Steam
I I Suppl.
C ) Direct Vent
n Other
~ AlC I
I I Con. Burner I
. Not Applicable
U Vent
. Not Applicable
. Other
Value
Value
Use/Nature Install HVAC for new office building.
of Work
Fees: Valuation $27,430.00
Issued By: ~
Plan Approval
$0.00
Permit Fee Paid
$367.50
Date 08/05/2005
0 Permit Voided I
Parcelld # 1329000400
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
Signature
Date
Agent/Owner
Address
PO BOX 191
HORICON
WI 53032 -191
Telephone Number
920-485-4883
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
HVAC Permit Work Card
Job Address 2380 STATE ROAD 44 Penmit Number 115631 Create Date 08/05/2005
Owner HWY 44 BUSINESS PLACE LLC Contractor SURE-FIRE INC
Category 512 -Ind. & Comm-Both Plan L5-29-Q405
Fuel ~ ~ 1,/1 Electric I ~ ~ Value $27,430.00
System 0 New I 0 Replace I 0 Other I
~ Forced Air I U Radiant I U Steam I ~ AlC I U Vent I
U Electric I U Hot Water I U Suppl. I U Con. Burner I
Chimney Type 0 Chimney A () Chimney B 0 Direct Vent . Not Applicable I
Heat Loss 0 As Approved () Existing . Not Applicable I Value 0
BTU Rate 0 As Per Plan 0 Variable . Other I Value
UselNature Install HVAC for new office building.
of Work
InspectIons:
Date 10/4/05
Type Final
Inspector Allyn Dannhoff
approved
I'.'~ "-",, '"
DatelTime requested:
Notice Type:
Phone Number:
Access:
Ready DatelTime:
Requested By:
0 Reinspect Fee 0 Fee Waived
0 Reinspect Fee Paid
--- - -- - - - - - - - - - -- - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- ----- - - - ----- - ----- - - - - - - - - - -- ---
~-I-
"""- /. commerce.wl.goy
~ i!E9JJ!J.t'!
Safety and Buildings
2331 SAN LUIS PL STE 150
GREEN BAY WI 54304
TDD #: (608) 264-8777
www.commerce.wi.gov/sb/
www.wisconsin.gov
Jim Doyle, Governor
Mary P. Burke, Secretary
August 17, 2005
CUST ID No. 262662
TERRANCE R ZlMMERLEE
SURE FIRE INC
617 WASHINGTON ST
PO BOX 191
HORICON WI 53032
ATTN: Buildings & Structures Inspector
BUILDING INSPECTION
CITY OF OSHKOSH
POB 1130
OSHKOSH WI 54902
CONDITIONAL APPROVAL
PLAN APPROVAL EXPIRES: 08/17/2006
er
SITE:
Highway 44 Business Place
2380 Hwy44
City of Oshkosh, 54903
FOR:
Facility: 663292 HIGHWAY 44 BUSINESS PLACE OFFICE BLDG 3 2380 HWY 44 OSHKOSH 54903
Description: !MC - HV AC System
Object Type: HV AC ICC System Regulated Object ID No.: 1024575
5,320 sq ft Area Heated
The submittal described above has been reviewed for conformance witb applicable Wisconsin Administrative Codes
and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in
chapter 101.01(10), Wisconsin Statutes, is responsible for compliance witb all code requirements.
The following conditions shall be met during construction or installation and prior to occupancy or use:
Key Items
mc 1004.3.2.4 Corridors shall not service as supply, return, exhaust, relief or ventilation air ducts or plenums.
Exceptions ONLY include use of a corridor as a source of makeup air for exhaust systems, and use of space
between tbe corridor ceiling and tbe floor or roof structure above if criteria is met.
Return air from the corridor is not permitted, the return air ducts from the corridor on Furnaces F-2 & Ff-3
must be eliminated.
Reminders
IMC 102.1/IMC 313/Comm 64.0313(3) All operating manuals concerning tbe HV AC equipment and its
maintenance shall be presented to tbe owner.
IFGC 302.3/IMC 302.3 Joist notching; stud cutting and notching; as well as bored holes in wood fi:anting
associated witb tbe installation ofHV AC equipment and its distribution system shall be limited as defined in this
code section. IFGC 302.3/IMC 302.3 Joist notching; stud cutting and notching; as well as bored holes in wood
fi:anting associated witb tbe installation ofHV AC equipment and its distribution system shall be limited as
defmed in this code section.
IMC 304.8 Provide equipment appliances installed at grade level witb a level concrete slab or oilier approved
material extending above adjoining grade, or suspend tbe equipment a minimum of 6" above adjoining grade.
IMC 313/Comm 64.0313(1) HV AC system balancing shall be performed, and a report shall be made available
to tbe department upon request.
IFGC 401lComm 65.0400 All gas piping installations shall comply witb NFP A 54, National Fuel Gas Code as
required by Comm 65.0400.
TERRANCE R ZIMMERLEE
Page 2
8/i 7/2005
.
IECC 503.3.3.5/IECC 803.2.7/IECC 803.3.3.4/Comm 63.0503(2)/Comm 63.0803(2)(e) Provide required
outside air intakes serving tempered or heated spaces witb motorized dampers which will close the damper and
prevent tbe intake of outside air into tbe building when tbe ventilating unit is not in operation. Barometric
controls shall not be used for tbe damper.
IECC 803/Comm 63.0803(2)(e) Exhaust openings serving tempered or heated spaces must be provided witb
automatic or self-activating back-draft dampers to prevent tbe intake of outside air into tbe building when tbe
exhaust units are not in operation, except as allowed by tbe code.
A copy of tbe approved plans, specifications and Ibis letter shall be on-site during construction and open to
inspection by autborized representatives oftbe Department, which may include local inspectors. If plan index sheets
were submitted in lieu of additional full plan sets, a copy of this approval letter and index sheet shall be attached to
plans tbat correspond witb tbe copy on file witb tbe Department. All permits required by tbe state or tbe local
municipality shall be obtained prior to commencement of construction/installation/operation.
In granting this approval tbe Division of Safety & Buildings reserves tbe right to require changes or additions should
conditions arise making tbem necessary for code compliance. As per state stats 101.12(2), notbing in this review
shall relieve tbe designer oftbe responsibility for designing a safe building, structure, or component.
Inquiries conceming this correspondence may be made to me at tbe telephone number listed below, or at tbe address
on Ibis letterhead.
Sincerely,
Fee Required $
Fee Received $
Balance Due $
470.00
470.00
0.00
Tony J Grzybowski
Building Plan Reviewer, Integrated Services
(920)492-5609, Mon.-Thr. 7:00 - 4:45, Fri 7:00 - 11:00
tgrzybowski@commerce.state.wi.us
cc: Peter R Ochs, Building Inspector, (920) 948-3500, Friday, 7:45 A.M. - 4:30 P.M.
Thomas Scharpf, Thomas James Real Estate LLC
"
"""- j commerce.wl.goY
~ i!E9J1!J.Q
Safety and Buildings
2331 SAN LUIS PL STE 150
GREEN BAY WI 54304
TDD #: (608) 254-8777
www.commerce.wi.gov/sb/
www.wisconsin.gov
Jim Doyle, Governor
Mary P. Burke, Secretary
July II, 2005
CUST ID No. 262662
TERRANCE R ZIMMERLEE
SURE FIRE INC
617 WASHINGTON ST
PO BOX 191
HORICON WI 53032
Fee Required $
Fee Received $
Balance Due $
320.00
320.00
0.00
REQUEST FOR ADDITIONAL INFORMATION
SITE:
Highway 44 Business Place
2380 Hwy44
City of Oshkosh, 54903
FOR:
Facility: 663292 HIGHWAY 44 BUSINESS PLACE OFFICE BLDG 3 2380 HWY 44 OSHKOSH 54903
Description: IMC - HV AC System
Object Type: HVAC ICC System Regulated ObjectlD No.: 1024575
5,320 sq. ft Area Heated
The submittal described above has been placed on HOLD and Four (4) sets of plans are being returned. The review and
approval is pending subject to receipt of tbe ADDITIONAL INFORMATION and re-submittal of a minimum of Four (4)
sets of revised plans as requested by Ibis letter. Upon receipt oftbe additional information and tbe revised plans, tbe plans
will be reviewed for compliance to applicable Wisconsin Administrative Codes and Wisconsin Statutes.
The following must be corrected and revised plans must accompany tbe re-submittal:
Key Items
IMC 401.3/Comm 64.0401(2) Provide a building exhaust ventilating system which will operate continuously
when people are in tbe building to provide tbe amount of exhaust specified in Comm Table 64.0403.
IMC 403/Comm 64.0403(8) Air change shall be provided as required by code while people are present.
IMC 403/Comm 64.0403(6)(0)1. Provide a minimum of outside air in tbe amount of7.5 cfinperperson in tbe
building. Simultaneously exhaust an equal amount of air. See Comm Table 64.0403.
The HVAC systems as designed do not provide the minimum outside requirements of the code, resubmit revised
plans.
IBC 1004.3.2.4 Corridors shall not service as supply, return, exhaust, relief or ventilation air ducts or plenums.
Exceptions ONLY include use ofa corridor as a source of makeup air for exhaust systems, and use of space
between tbe corridor ceiling and tbe floor or roof structure above if criteria is met.
IBC 711.3 Penetrations into or tbrough flIewalls, flIe barriers, smoke barrier walls, and flIe partitions shall
comply witb this section.
IMC 607 Provide flIe dampers as required where ductwork pierces flIe-rated construction. One hour systems
have exemptions under certain conditions. Fire dampers may not be used witb firewalls per !MC 607.5.1.
Corridor 300 has been designed as a rated corridor and therefore any penetrations shall be addressed.
TERRANCE R ZIMMERLEE
Page 2
7/1112005
Reminders
IMC 313/Comm 64.0313(3) All operating manuals concerning tbe HV AC equipment and its maintenance shall
be presented to tbe owner.
IMC 313/Comm 64.0313(1) HV AC system balancing shall be performed, and a report shall be made available
to tbe department upon request.
IMC 304.8 Provide equipment appliances installed at grade level witb a level concrete slab or oilier approved
material extending above adjoining grade, or suspend tbe equipment a minimum of 6" above adjoining grade.
IECC 503.3.3.5/IECC 803.2.7/IECC 803.3.3.4/Comm 63.0503(2)/Comm 63.0803(2)(e) Provide required
outside air intakes serving tempered or heated spaces witb motorized dampers which will close tbe damper and
prevent tbe intake of outside air into tbe building when tbe ventilating unit is not in operation. Barometric
controls shall not be used for tbe damper.
. IECC 803/Comm 63.0803(2)( e) Exhaust openings serving tempered or heated spaces must be provided witb
automatic or self-activating back-draft dampers to prevent tbe intake of outside air into tbe building when tbe
exhaust units are not in operation, except as allowed by the code.
IFGC 40l/Comm 65.0400 All gas piping installations shall comply witb NFP A 54, National Fuel Gas Code as
required by Comm 65.0400.
Also Address
Revised plans are required to be submitted. The fee for a re-submittal received prior to a derual action is $50 +
$100 submittal fee ~ $150. Include eitber 4 revised plans or one revised plan & 3 updated index sheets showing
plan sheet revision dates.
Send your resubmittal into tbe address listed above, unless otberwise noted, and tbe department will review tbe
resubmittal witbin 5 working days of receipt date. Please include a copy of this letter witb your re-submittal.
If you have any questions, after reading tbe above comments and related code sections cited, please call me at tbe
telephone number below. Iftbe above requested information and/or plans are not received witbin 30 business days
oftbe date of this correspondence, Ibis submittal will be returned denied. No fees will be refunded, and a new fee,
application form, and submittal of plans/specifications will be required should you desire to continue witb Ibis
project. The code in effect attbe time of new submittal would apply.
Sincerely,
Tony J Grzybowski
Building Plan Reviewer, Integrated Services
(920)492-5609, Mon.-Thr. 7:00 - 4:45, Fri 7:00 - 11:00
tgrzybowski@commerce.state.wi.us
cc: Peter R Ochs, Building Inspector, (920) 948-3500, Friday, 7:45 A.M. - 4:30 P.M.
Building Inspection, City of Oshkosh, 920/236-5051
¡
!
.
~.'
,
Buildings, HVAC, Lighting Compliance Statement
This form is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical
designer) observing construction of projects within buildings with total areas exceeding 50,000 cubic feet and construction
of antennas, towers, and bleachers (ILHR 50.10). Failure to submit this form may result in penalties as specified in
ILHR 50.26 and/or local ordinances.
General Instructions: Prior to the initial occupancy of new buildings or additions and the final occupancy of
altered existing buildings, submit this completed and signed form to:
. The municipal building inspection office and
. Safety and Buildings, P.O. Box 7162, Madison, WI 537~-r-:r16-2~ f?= W .':C=
Personal infonmation you provide may be used for secondary purposes [Privacy Law, s. 15.04 (1)(m)]. F~:.t \.~ I:: ¡¡ V~:
1. PROJECT INFORMATION: Please fill in the following with information from your plan approval letter. -,~
Transaction 10 Number -U 4 q 'D b 1 OCT 0 6 2005
Site Number fø,"7 aó( t ~
Site location (number & stree~~Q~~~Jq'1II w.~1( corm¿iUNíilY Or-
~ City 0 Village 0 Town of 0 ~~ \LD~~ County of LJ¡ "'1,\ e. (?" if 0
2. PURPOSE OF THIS STATEMENT: (Check Box A, B, C, or D to indicate purpose and complete any other
applicable boxes and information. Attach additional pages if necessary.)
Check those which apply: CI Building Object 10 # \II HVAC Object ID #
CI Lighting Object 10 #
CI Partial Completion
A) II
Description of Portion Completed
Statement of Substantial Compliance
To the best of my knowledge, belief, and based on onsite observation, construction of the foilowing building and/or HVAC
items applicable to this project have been completed in substantial compiiance with the approved plans and
specifications.
(J BUILDING ITEMS
1. Structural system including submittal and erection of ail building
components (trusses, precast, metal building, etc.)
2. Fire protection systems (sprinklers, alarms, smoke detectors) designed,
instailed, and tested (including forward flow on back flow devices) by
appropriately registered professionals
3. Shaft and stairway enclosure
4. Exits including exit and directional lights
5. Fire-resistive construction, enclosure of hazards, fire wails, labeled
doors, class of construction
6. Sanitation system (toilets, sinks, drinking facilities)
7. Barrier-free including Comm 18 elevators and lifts
8. ILHR 63 enérgy envelope
g. Ail conditions of building plan approval and applicable variances
The following Items are not In compliance and must be addressed:
~ HVAC ITEMS
1. HVAC system including final test
(lLHR 64.53)
2. Ail conditions of HVAC plan approval and
applicable variances
(J LIGHTING ITEMS
1. Exterior lighting & conirol requirements
2. Interior lighting & control requirements
3. Ail conditions of lighting plan approval and
applicable variances
B) CI Statement of Noncompliance
Due to the foilowing listed violations, this project is not ready for occupancy:
C) CI Supervising Professional Withdrawn From Project (Use A or B above to indicate project status as of this date.)
0) CI Project Abandoned
3. SUPERVISING PROFESSIONAL SIGNATURE FOR: , k -
(J Building iJ HVAC (J Lighting ~;t- t"o-/\c..e.. ~,:::r; ,\...... v....-('.... .e.. Date ({)..... s- D J,
Name(pleaseprinlor~pe) ~'
PhonenumbeH,;)JO-ygÇ- customerID#?-b 2- f:b '2.- Signature.L ~
~€Q] V
SBD-9720 (R.05198)