Project Address: 3238 Isaac Ln
Submitted By: Garry Decker
Plan Number: GI-34-0605
Date Reviewed: 6/21/05
Reviewed By: Brian Noe
[g Conditionally Approved
Result of Plan Review:
0 Withheld Pending Approval of Additional Information
0 Not-Approved, Plans Returned for Revisions
0 Mailed
0 Faxed
[g Delivered with Permit
Conditions Noted on Plan Review
1. 21.04 Effective 1/1/05 Guardrail opening size has been changed to a maximum of 4 inches.
2. 21.02 Complete truss plans and layout are required to be onsite at time of rough inspection
3. 21.09 Smoke detectors are required to be provided in each bedroom and adjacent to all
sleeping areas.
4. Comm 21.25(1 )(b) Bracing. Exterior walls shall be braced at the comers.
1. Nominal 1 inch by 4 inch continuous diagonal members set into the face of the studs at
an angle between 450 and 600; or
2. Four feet by 8 feet plywood sheathing panels not less than '/,,-inch thick for l6-inch
stud spacing and not less than '/8 inch thick for 24-inch stud spacing; or
3. Preformed metal T-bracing not less than 22 gage (.0296 inches) thick and 1'/, inch
wide; or
4. Other approved wind bracing materials.
5. No structure is permitted within any Easement located on the property.
6. 21.02 Point loads must transfer properly- Caution on bearing requirements for beams.
7. The drainage will be required to be completed in compliance with the approved grading and
drainage plan.
8. Heat loss calculations are required to match the actual construction.
The submittal described abave has been reviewed for conformance with the State of Wisconsin Uniform Dwelling Code. The
submittal has been CONDITIONALLY APPROVED. This is a limited review. Ultimately it is the applicant / owners
responsibility to comply with all applicable codes, statues and ordinances, and the conditions of this approval.
RcI
Page 1 of2
9, Garage spaces shall be separated from dwelling unit in accordance with Comm 21.08.- The
door and frame assembly between the dwelling unit and an attached garage shall be listed an
labeled by an independent testing agencv ( i.e. UL, ETL, WH, ) as having a minimum fire-resistive
rating of20 minutes. ALL drywall joints are required to be taped / sealed unless the joints
are fitted so that the gap is no more than 1/20th of an inch (a dimes thickness) and backed by
solid wood or drywall with joints staggered.
10. All Penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in studs
used for return air spaces.
11. The property owner and applicant is responsible for compliance with Comm 21.125 (Erosion
Control). When installing access drives, a minimum of 2"-3" diameter stone is required for a
minimum 6 inch depth, 14'-20' wide, and 30' -50' in length. Erosion control measures are
required to be maintained until the permanent lawn has been established.
12. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(sediment) must be removed from the street at the end of each work day. Repair of any
siltation, or erosion damage to adjoining surfaces and drainage ways resulting from land
development or disturbing activities.
13. All site grading must be done in accordance with the approved drainage plan on file in the
public works office -located on 3rd floor City Hall.
S~oTAPP~dw~K~ elM j/~ VatlY. ~ 'd3. () S
The submittal described above has been reviewed for conformance with the State of Wisconsin Uniform Dwelling Code. The
submittal has been CONDITIONALLY APPROVED. This is a limited review. Ultimately it is the applicant lowners
responsibility to comply with all applicable codes, statues and ordinances, and the conditions of this approval.
Re.
Page 2 of2