HomeMy WebLinkAbout0114457-HVAC (RTU's) e OSHKOSH ON THE WATER CITY OF OSHKOSH No 114457 HVAC PERMIT - APPLICATION AND RECORD Job Address 2251 BADGER AVE Owner CURWOOD INC Create Date 06/01/2005 Contractor BASSETT MECHANICAL 1 1 Gas 1 1 Oil Fuel 1,(1 New 1 System U Forced Air U Radiant 1 1 Electric 1 1 Hot Water Chimney Type () Chimney A 0 Chimney B Heat Loss 10 As Approved 0 Existing BTU Rate 10 As Per Plan 0 Variable Category 520 - Ind. & Comm-Other 1,(1 Electric Plan Not Req Per AD 1 1 Solar 1 1 Solid 1 1 1 Other 1 l..j Vent 1 1 1 Replace U Steam 1 1 Suppl. U A/C 1 1 Con. Burner 0 Direct Vent . Not Applicable . Not Applicable . Other Value 0 Value Use/Nature IND/ Installation of (2) 40,000 CFM RTU - mounted on steel structures to provide heat relief in the plant per letter addressed to Allyn Dannhoff of Work dated 5/23/05. Fees: Valuation $150,000.00 Plan Approval $0.00 Permit Fee Paid $930.00 Issued By: Date 06/03/2005 U Permit Voided 1 Parcelld # 1325000000 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address PO BOX 7000 KAUKAUNA WI 54130 - 7000 Telephone Number 800-236-2500 --- To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. If you have any questions, please contact me at (920) 759-252 ext. 509. S{n4re'~ ,-\J'~ ~o~n. Ter es, P.E., CEM. \é~ect Engineer ¡rl;;;~- JNT/dms .irhr -~C: Mike Brosch - Curwood . (j - '-; Jeff Beyersdorf . M~~~~ 1215 Hyland Avenue po. Box 7000 Kaukauna, WI 54130 920.759-2500 800-236-2500 FAX 920-759-2525 ~w.b"'etlm"h";"'."m May 23, 2005 Allyn Dannhoff City of Oshkosh 215 Church Avenue Oshkosh, WI 54902-1130 MAY 2 6 2005 RE: CSF Plant Ventilation Dear Allyn, Attached you will find the HVAC permit application with the check in the amount of $1,010.50. Below is a description of the existing plant HVAC system and the proposed ventilation addition. Existinq HVAC Svstem: Exhaust fan summary EF-1 1250 CFM 4200 CFM 4200 CFM 4200 CFM 25000 CFM 18500 CFM 4300 CFM 61650 CFM Toilet Room Ink Mixing Ink Mixing Ink Mixing Coater General Exhaust Press Exhaust to Incinerator EF-2 EF-3 EF-4 EF-5 Incinerator EF-6 Total Exhaust Make-up air (2) make-up air units. King model DCFOC-230B, 80/20 units with building pressure controls. Capacity of these units are 60,000 CFM each, 6,050 MBH each, The purpose of these units are to maintain a slight positive building pressure in reference to the outdoors. There are existing gas fired unit heaters located along the perimeter of the facility to offset building heat loss. New Ventilation Svstem: Provide (2) 40,000 CFM roof mounted air handling units. These units will be mounted on a structure steel platform. The platform is provided by CR Meyer. Each unit weighs 9,352 Ibs. The air handling units will contain: mixing box, 2" thick 30% efficient filters, chilled water coils and a supply fan section. The chilled water coils will not be piped at this time and will remain inactive. The main purpose of the units at this time is to provide heat relief in the plant in spring, summer and fall. A control panel will be provided. A remote bulb senses space temperature and modulates the mixed air dampers. A low limit discharge controller will not permit the discharge temperature to drop below 60°F. A freeze thermostat will de-energize the unit and close the outside air dampers if the mixed air temperature drops below 45°F. As you mentioned, plans do not have to be submitted for this project. This letter, along with the HVAC permit will allow us to proceed with the work.