Loading...
HomeMy WebLinkAbout0114397-Electric (upgrade) e OSHKOSH ON THE WATER CITY OF OSHKOSH No 114397 ELECTRIC PERMIT - APPLICATION AND RECORD Job Address 0 Change 0 Temp Owner DANIEL E DOWLING Create Date 06/02/2005 Category 654 - Industrial-Service Change Plan 10 Overhead 0 N/A Type . Underground Circuits 0 Fixtures 0 Switches 0 Receptacles 0 3001-3015 N MAIN ST Contractor RIPON ELECTRIC INC Service 18 New Volts Amps 0 Appliances Use/Nature of Industrial/ 2000 amp service, feeders to existing panels. Work Fees: Valuation $40,808.00 Plan Approval $0.00 Permit Fee Paid $307.00 Issued By: Date 06/02/2005 U Permit Voided I Parcelld # 1519600502 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address 510 ASPEN ST RIPON WI 54971 - 0 Telephone Number 920-748-6606 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. Electric Permit Work Card Jo.b Addr.ess 3001-3015 N MAIN ST Owner DANIEL E DOWLING Permit Number 114397 Create Date 06/02/2005 Contractor RIPON ELECTRIC INC Category 654 - Industrial-Service Change 0 ChangeO Temp 0 N/A I Type 0 Overhead Circuits 0 . Underground ON/A Fixtures 0 Receptacles Value $40.808.00 Service b New Volts Amps 0 Switches 0 Fee $307.00 D Appliances Use/Nature ofWork Industrial/2000 amp service. feeders to existing panels. Inspections: Date Type Note Inspector Request Line -I called Mike 6/2/05 @ 8:18 a.m. to ask for permit #. Mike stated the owner of the building would be bringing in the application with the payment today. I explained that I did not have anything to enter the inspection request against until the permit is issued. I also clarified when he wanted the inspection as the message was unclear. Mike will call back with the inspection request once the permit is issued. MC DatelTime requested: 06/01/2005 03:06 PM Access: Notice Type: Phone Number: Ready DatelTime: 06/06/2005 08:00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid ------------------------------_uu_-----------------------------_u_--------------. Date 06/06/2005 Type Service Inspector Kevin Benner no time Request Line - would like late Monday morning, electrician on site Talked to Shawn @229-9712 Date/Time requested: 06/0212005 12:23 PM Access: Notice Type: - Phone Number: 748-6606 Ready DatelTirne: 06/06/2005 11 :00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid RIPON ELECTRIC INC-Mike - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - u- - - - - - - - - - - - - - --. Electric Permit Work Card J~b Address 3001-3015 N MAIN ST Owner DANIEL E DOWLING Permit Number 114397 Create Date 06/02/2005 Contractor RIPON ELECTRIC INC Category 654 - Industrial-Service Change Circuits I Type 0 Overhead 0 . Underground 0 N/A Fixtures Receptacles 0 Value $40,808.00 Service b New Volts 0 ChangeO Temp 0 N/A Amps 0 Switches 0 Fee $307.00 D Appliances Use/Nature of Work Industrial/2000 amp service, feeders to existing panels. Inspections: Date 06/30/2005 Type Service Inspector Kevin Benner not approved Request Line Bond pull box on the exterior of the building, Verify when the GFP test is to be conducted by Sq.D. E.C. stated the the AIC is 55K. The MCB is 65KAIC. Shawn from the E.C. called and stated the pull box is bonded Called WPS 6/30/5 1 :30 PM will mail when the GFP test is done. DatelTime requested: 06/27/2005 02:05 PM Access: Notice Type: Phone Number: 229-9712 Ready DatelTime: 06/30/2005 07:00 AM Requested by: -- 0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid RIPON ELECTRIC INC-Shaun -----------------------------------------------------------------------------_u_--. Date 07/1212005 Type Re Service Inspector Kevin Benner no time Called the E.C. to provide the GFP Test info, then I can complete the inspection DatelTime requested: 06/30/2005 03:30 PM Access: Notice Type: Phone Number: Ready DatelTime: 07/05/2005 10:00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid RIPON ELECTRIC INC Mike --------------------------------------------------------------------------------_u. I JUL-13-2005 09:42 VIKING ELECTRIC SUPPLY '*~ ff.()( /I ?(lJJ~ { ~ 920 236 6050 P.O1 r...... .. uare 1'VIC8S Cue"""': PRD-X Addreaa: Nl1151 TowervilW Drive Add.....: c/o Rlpon Electric Greenvllle, WI 3001 N. Main Street OSftk05h WI Phe~! 9200II51.3781 .."""'" 920-228-9712 ,.~..... N....: Jim N..\I8h8k Oontoot NI\I'nO' shawn KreUCI8f JobiOonlroot... Eq"lomentTIII'" Service En~nce Dah< 5 Julv. 21105 FO 43020511800l1oOO4 ~~~~~ =-~'~~~.~::] sœ.~~: :L In:' d : :OWERPACT 8 11ft11m &>rial ~ :-0 5IlOO5 ~18N&B~~~~__~_i_~.~ Forn . MlCROLOGIO T : II.DA s.rtolt: oa47~17 ""'-- .. Fabnd MUll MT- I; ¡¡.m-........ ~Ratt .'" 2DIID 2IICIO 2ODD A :!GaaA LT Swímh Sallino 10 1 1 xln A , nn. Time PIck" IIA 1 1 t ~In IiØOØ A """" Timo DoI-"" 0.5 o.s D.5 See .....roe DeftnItO Mln. Time L.oo n.m~\ 011 011 OFF SI>ortT"",Pi";;"/lod.lml U 1.5 1.5 XiI 3000 A ShOrt Tn O<iav /1Sd\ 0.1 0.1 D.1 s..o 01\ Insta- ""'kun II~ . :& 2 xln _II """,nd FOUII i'IoICU"lol a... 0.25 o.:IG xln lIOII A a"",ntlF...n"",...'lðl a.1 D.1 D.' See On ~ Fault Puoh 10 Trtn By- FFTK Filo ., PRO- ::trfít~<::.:!1!~tl;;::.t.'!I,:r;;;;'Ji~X;J',1 iE1fþ¡¡¡g 1i Time 16.1$- S" SOO D.O4 See 0.14 S.. ¡¡Io"', -- "".. "".. p- p_r TlmoF'iGku If ShortTtmø Fisk. I 1m 111._. Pick" II Ground F..~ ""'" I T I Level '!WiT A 1.3';1 xiI S5OD A 1.nll, l1OlIO A 2.5 I In 1000 A 0.5 x In Comments I $"hoelder Electric PRO-X.xls Page I of3 . 07/13/2005 09:02AM JUL-13-2005 09:43 VIKING ELECTRIC SUPPLY 920 236 6050 P.O2 --- .- _n- ".- n n ...- --- _.__.n_- ..... _no ---. -. --.. '. I ., ISIa- No. IA1ØI1IIaJv SWitçh lOA NA III..", SIIIn.;,""" NA OVete",...., Trio - ISO~ NIl ~SW1tçhIO~O[)/c::rI' NA ...",...,._tEF1 NA ¡¡;¡;¡u 10 CI-SoMtl:h 'P'" NIl Þ MW{81'O11k SWi1oh IOADI CA'" NA P"""""'mlCb/A O...U - IM2CI MECI NA , C'" NA $11""'Tri" 1'-"" NA ShuntOI"".r~ NA ¡¡¡;;;¡;::;: T -. 'M"" NA eeelrioal Pooh 10 0Ie&A 'BP"'" NIl _';"""'/RES\ NA OoonfOIo8"""""'T"'~- OK o..rOII... Ocunter NA ~ Co'noelE> NA Þ.toCn""'" NA e"""",, WI- Con....,.- 01< ~P--~""""",, 01< G- C""'~"'" OK llmoJœf"""""'iII po.IOOk NA Cradle ~""""'Id -lock NA 0_1 A..klno Meclllnl- NA Door In¡,,rIook NA ~I;ctlOrlntor1a;k NA ~;;olnl8riool< IlIA "",,",.,-polIan NA 1.11"" Jaws ~¡.", NA ßI8OI<or8 Ceb.. Rod Inlonoel< NA 6....k", ",a plll"" - OK O"'¡..mQJfItinoh.- NA ""'no>rolA an~ OfQoo1linoss 01< Comments Thlli ground fault lesling was to satlslly the eleclricallnspector only.AII functions passed, breaker Is suitable for continuous llse in an Indus1rial environment. 8ohnelder ElectnQ PRD-X."I" Page2of3 07/13/2005 09:02AM TOTAL P.02