HomeMy WebLinkAbout0113352-Building ~ OJHKOJH ON 'HE W^'" City of Oshkosh Division of Inspection Services 215 Church Avenue POBox 1130 Oshkosh WI 54903-1130 Office 920-236-5050 Fax 920-236-5084 PLAN REVIEW Project Address: 4416 Island View Dr Submitted By: Timothy and Stacey Eireman PlanNumber: GI-017-0405 Date Reviewed: April 7,2005 Reviewed By: BrianNoe Result of Plan Review: ¡g¡ Conditionally Approved 0 Withheld Pending Approval of Additional Infonnation 0 Not-Approved, Plans Returned for Revisions 0 Mailed 0 Faxed ¡g¡ Delivered with Permit Conditions Noted on Plan Review 1. 21.04 Effective 1/1/05 Guardrail opening size has been changed to a maximum of 4 inches. 2. 21.02 Complete truss plans and layout are requITed to be onsite at time of rough inspection 3. 21.09 Smoke detectors are requITed to be provided in each bedroom and adjacent to all sleeping areas. 4, Comm 21.25(1)(b) Bracing. Exterior walls shall be braced at the comers. 1. Nominal 1 inch by 4 inch continuous diagonal members set into the face of the studs at an angle between 45° and 60°; or 2. Four feet by 8 feet plywood sheathing panels not less than '/,,-inch thick for l6-inch stud spacing and not less than 3/, inch thick for 24-inch stud spacing; or 3. Preformed metal T-bracingnot less than 22 gage (.0296 inches) thick and PI, inch wide; or 4. Other approved wind bracing materials. Note: Outside corners of house and the corners of the breakfast area do not appear to comply - Provide framing detail that will provide equivalent lateral bracing. - Please provide this information to our officeprior to requesting a rough inspection. 5. Provide structural calculations I ftaming detail for breakfast area roof and wall ftaming. The submittal described above has been reviewed for conformance with the State of Wisconsin Uniform Dwelling Code. The submittal has been CONDmONALLY APPROVED. This is a limited review. Ultimately it is the applicant / owners responsibility to comply with all applicable codes, statues and ordinances, OJld the conditions of this approval. ;\OSRKOSRM/SFS;USERS;/"'¡anni2005 Res Plan Re»iews\4416 /slnnd View Dr Plan Review.doe Page I of2 6. Comm 21.25 (I)(a) Studs. Wood studs shall comply with the size and spacing requirements indicated in Table 2I.25-A. Studs in the exterior walls shall be placed with the wide faces perpendicular to the plane of the wall. Tall walls in foyer area and stairway exceed maximum height allowed by table 11.15 - Provide details as to how these areas will be framed. Please provide this information to our office prior to requesting a rough inspection. 7. 21.05 Safety glass is required in windows adjacent to doors, areas adjacent to stairways, and areas adjacent to whirl pool/tubs. 8. Hydromassage tubs are required to have and access panel to motor. The access panel must be accessible without removing the finish material. 9. 21.02 Point loads must transfer properly- Caution on bearing requirements for beams, and footing sizes below columns. Beam Calculations indicate there may be inadequate column footing size, and bearing capacity in a number of locations. Truss drawing were not provided, therefor load transfer can not be determined 10. The drainage will be required to be completed in compliance with the approved grading and drainage plan. 11. Heat loss calculations are required to match the actual construction. 12. Garage spaces shall be separated ITom dwelling unit in accordance with Comm 21.08.- The door and ITame assembly between the dwelling unit and an attached garage shall be listed an labeled by an independent testing agencv ( i.e. UL, ETL, WH, ) as having a minimum fire-resistive rating of 20 minutes. ALL drywall joints are required to be taped / sealed unless the joints are fitted so that the gap is no more than 1/20th of an inch (a dimes thickness) and backed by solid wood or drywall with joints staggered. 13. All Penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in studs used for return air spaces. 14. The property owner and applicant is responsible for compliance with Comm 21.125 (Erosion Control). When installing access drives, a minimum of2"-3" diameter stone is required for a minimum 6 inch depth, 14'-20' wide, and 30' -50' in length. Erosion control measures are required to be maintained until the pennanent lawn has been established. 15. All stonn sewer inlets must be protected with approved erosion control devices. Tracking (sediment) must be removed ITom the street at the end of each work day. Repair of any siltation, or erosion damage to adjoining surfaces and drainage ways resulting ITom land development or disturbing activities. ~. S~t7TAppl«:ad; )Q~ / tJatlY. £j- J -0:)' The submittal described above has been reviewed for conformance with the State of Wisconsin Uniform Dwelling Code. The submittal has been CONDI1TONALLY APPROVED. This is a limited review. Ultimately it is the applicant / owners responsibility to comply with all applicable codes, statues and ordinances, and the conditions of this approval, \\OSHKOSFfMISFS\USERSII"iannl2005 Res Plan Reviews\4416 Island View Dr PI"" Review.doe Page20f2