PLAN REVIEW
Project Address: 1230 Heidi Haven Dr
Submitted By: Rusch Homes LLC
Plan Number: G1-013-0305
Date Reviewed: Apri111, 2005
Reviewed By: Brian Noe
181 Conditionally Approved
0 Withheld Pending Approval of Additionallnforrnation
0 Not-Approved, Plans Returned for Revisions
Result of Plan Review:
0 Mailed
0 Faxed
181 Delivered with Permit
Conditions Noted on Plan Review
1. 21.04 Effective 1/1/05 Guardrail opening size has been changed to a maximum of 4 inches.
2. 21.02 Complete truss plans and layout are required to be onsite at time of rough inspection
3. 21.09 Smoke detectors are required to be provided in each bedroom and adjacent to all
sleeping areas.
4. Comm 21.25(1)(b) Bracing. Exterior walls shall be braced at the corners.
1. Nominal 1 inch by 4 inch continuous diagonal members set into the face of the studs at
an angle between 45° and 60°; or
2. Four feet by 8 feet plywood sheathing panels not less than '/I,-inch thick for l6-inch
stud spacing and not less than 'I, inch thick for 24-inch stud spacing; or
3. Preformed metal T-bracing not less than 22 gage (.0296 inches) thick and PI. inch
wide; or
4. Other approved wind bracing materials.
5. 21.05 Safety glass is required in sidelights adjacent to door and windows adjacent to patio
door.
6. The drainage will be required to be completed in compliance with the approved grading and
diainage plan.
7. Heat loss calculations are required to match the a«tual construction.
The submittal described above has been reviewed for conformance with the State of Wisconsin Uniform Dwelling Code. The
submittal has been CONDITIONALLY APPROVED. This is a limited review. Ultimately it is the applicant / owners
responsibility to comply with all applicable codes, statues and ordinances, and the conditions of this approval.
R..\I"'Ìlmnll005 Re.' Pian R",¡',,""1230 Reidi Haven Dr PI"" R(oiew.do(
Pagel of2
8. Garage spaces shall be separated from dwelling unit in accordance with Comm 21.08.- The
door and frame assembly between the dwelling unit and an attached garage shall be listed an
labeled by an independent testing agencv ( i.e. UI., ElL, WH, ) as having a minimum fife-resistive
rating of 20 minutes. ALL drywall joints are required to be taped / sealed unless the joints
are fitted so that the gap is no more than 1/20th of an inch (a dimes thickness) and backed by
solid wood or drywall with joints staggered.
9. All Penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in studs
used for return air spaces.
10. The property owner and applicant is responsible for compliance with Comm 21.125 (Erosion
Control). When installing access drives, a minimum of 2"-3" diameter stone is required for a
minimum 6 inch depth, 14'-20' wide, and 30'-50' in length. Erosion control measures are
required to be maintained until the permanent lawn has been established.
11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(sediment) must be removed from the street at the end of each work day. Repair of any
siltation, or erosion damage to adjoiuing surfaces and drainage ways resulting from land
development or disturbing activities.
12. All site grading must be done in accordance with the approved drainage plan on file in the
public works office -located on 3rd floor City Hall.
S~of'Aþþlú:ant;
~
VatlY.
tj/r-/ó 5'
The submittal described above has been reviewed for conformance with the State of Wisconsin Uniform Dwelling Code. The
submittal has been CONDillONALLY APPROVED. This is a limited review. Ultimately it is the applicant / owners
responsibility to comply with all applicable codes, statues and ordinances, and the conditions of this approval.
H.\z,,'iaanìl005 R", Plan R,-view"'1230 Heidi H""" Or Pbm 1/",'iew.dOl'