Loading...
HomeMy WebLinkAbout0113462-Building , (f) OJHKOfH ON'H'WA'" City of Oshkosh Division of h1spection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 Office 920-236-5050 Fax 920-236-5084 PLAN REVIEW Project Address: 1230 Heidi Haven Dr Submitted By: Rusch Homes LLC Plan Number: G1-013-0305 Date Reviewed: Apri111, 2005 Reviewed By: Brian Noe 181 Conditionally Approved 0 Withheld Pending Approval of Additionallnforrnation 0 Not-Approved, Plans Returned for Revisions Result of Plan Review: 0 Mailed 0 Faxed 181 Delivered with Permit Conditions Noted on Plan Review 1. 21.04 Effective 1/1/05 Guardrail opening size has been changed to a maximum of 4 inches. 2. 21.02 Complete truss plans and layout are required to be onsite at time of rough inspection 3. 21.09 Smoke detectors are required to be provided in each bedroom and adjacent to all sleeping areas. 4. Comm 21.25(1)(b) Bracing. Exterior walls shall be braced at the corners. 1. Nominal 1 inch by 4 inch continuous diagonal members set into the face of the studs at an angle between 45° and 60°; or 2. Four feet by 8 feet plywood sheathing panels not less than '/I,-inch thick for l6-inch stud spacing and not less than 'I, inch thick for 24-inch stud spacing; or 3. Preformed metal T-bracing not less than 22 gage (.0296 inches) thick and PI. inch wide; or 4. Other approved wind bracing materials. 5. 21.05 Safety glass is required in sidelights adjacent to door and windows adjacent to patio door. 6. The drainage will be required to be completed in compliance with the approved grading and diainage plan. 7. Heat loss calculations are required to match the a«tual construction. The submittal described above has been reviewed for conformance with the State of Wisconsin Uniform Dwelling Code. The submittal has been CONDITIONALLY APPROVED. This is a limited review. Ultimately it is the applicant / owners responsibility to comply with all applicable codes, statues and ordinances, and the conditions of this approval. R..\I"'Ìlmnll005 Re.' Pian R",¡',,""1230 Reidi Haven Dr PI"" R(oiew.do( Pagel of2 8. Garage spaces shall be separated from dwelling unit in accordance with Comm 21.08.- The door and frame assembly between the dwelling unit and an attached garage shall be listed an labeled by an independent testing agencv ( i.e. UI., ElL, WH, ) as having a minimum fife-resistive rating of 20 minutes. ALL drywall joints are required to be taped / sealed unless the joints are fitted so that the gap is no more than 1/20th of an inch (a dimes thickness) and backed by solid wood or drywall with joints staggered. 9. All Penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in studs used for return air spaces. 10. The property owner and applicant is responsible for compliance with Comm 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required for a minimum 6 inch depth, 14'-20' wide, and 30'-50' in length. Erosion control measures are required to be maintained until the permanent lawn has been established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (sediment) must be removed from the street at the end of each work day. Repair of any siltation, or erosion damage to adjoiuing surfaces and drainage ways resulting from land development or disturbing activities. 12. All site grading must be done in accordance with the approved drainage plan on file in the public works office -located on 3rd floor City Hall. S~of'Aþþlú:ant; ~ VatlY. tj/r-/ó 5' The submittal described above has been reviewed for conformance with the State of Wisconsin Uniform Dwelling Code. The submittal has been CONDillONALLY APPROVED. This is a limited review. Ultimately it is the applicant / owners responsibility to comply with all applicable codes, statues and ordinances, and the conditions of this approval. H.\z,,'iaanìl005 R", Plan R,-view"'1230 Heidi H""" Or Pbm 1/",'iew.dOl' Page 2 of2 ~..__.