HomeMy WebLinkAbout0113304-Building e OSHKOSH ON THE WATER Job Address 1700 OREGON ST CITY OF OSHKOSH No 113304 BUILDING PERMIT - APPLICATION AND RECORD Owner WITZKE'S TAVERN LLC Create Date 04/01/2005 Designer Contractor VIENOLA BROS. Category 204 - Addition Amusement, Social, Recreation Plan 03-16-0405 Type 18 Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning C3 Class of Const: VBibc Size irreg Unfinished/Basement 0 Sq.Ft. Rooms 0 Height 0 Ft. Finished/Living ~ Sq. Ft. Bedrooms 0 Stories 1 Garage ~ Sq. Ft. Baths 0 U Projection 1 Canopies 0 Signs 0 Foundation 8 Poured Concrete 0 Floating Slab 0 Concrete Block 0 Post 0 Pier 0 Treated Wood 0 Other Occupancy Permit Required Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures Tavern - Archery Range - 4196 sf addition for Archery range and banquet room. Remodel various areas of existing building for accessible restrooms, kitchen, storage. Use/Nature of Work HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $185,000.00 Plan Approval $0.00 Permit Fee Paid $619.00 Park Dedication $0.00 Issued By: Date 04/05/2005 Final/O.P. 00/00/0000 U Permit Voided 1 Parcelld # 1400120000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address PO BOX 8042 Agent/Owner OSHKOSH WI 54903 - 8042 Telephone Number 303-0934 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. "'ò ZONING/LAND USE COMPLIANCE CHECKLIST JOB LOCATION: 1700 OREGON STREET, WITZKE'S TAVERN PROPERTY OWNER/CONTRACTOR: VIENOLA BROS CONSTRUCTION DATA: 0 New Construction ~ Addition ZONING: C-3 0 Alteration TYPE OF CONSTRUCTION: (i.e. fence, pool, parking lot, sign, etc.) 4196SF BUILDING ADDITION, PARKING LOT EXPANSION, RAZE EX. GARAGE, BUILD NEW 1800SF STORAGE BLDG COMPLIANCE CHECKLIST COMMENTS: . Removal and grading/reconstruction of the off-street parking area in the 25 foot ITont yard setback to W. I ih A venue and 5 foot buffer area ITom parking lot to the east is not permitted. If reconstruction is desired, a variance must be secured to permit the parking area to project into the 25 foot ITont yard setback area and 5 foot side yard parking lot buffer setback area. New portion of parking are must provide a 5 foot setback from east property line. No information has been provided in regard to placement of rooftop or ground level mechanical equipment and locations of wall or ground mount utility boxes. These items shall be screened from view ITom the adjacent streets and residences, per section 30- 35(1)(5). No information provided regarding exterior lighting. Exterior building lighting must meet requirements of section 30-35(K). DEFICIENT 0 Use 0 Lot Width 0 Lot Area 0 Lot Area Per Family 0 Floodplain 0 Front Yard 0 Front Yard Side Street DEFICIENT 0 RearYard 0 Side Yards 0 Buildin9 Area 0 Parking Standards 0 Off-Street Loading Standards 0 Vision Clearance 0 Transitional Yard Standards 0 Parking Lot Lighting . . . DEFICIENT 0 Landscape Standards 0 Height 0 Conditions of Approval 0 Compliance with P.C. or BZA Conditions of Approval 0 Signage Standards 0 Mechanical Equip. Screening 0 Other REVIEW AUTHORITY As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approve all plans, except the following: (1) Alterations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc.. when Ihe use is conforming and when no change is proposed. 18:1 APPROVED -1L Plan Commission Action Required BOANariance(s) Required Parkinq iot reconstruction REVIEWED BY: Matt Tucker 0 DENIED DATE: 03/31/2005 2003 n n OJ CD I n n ~I /""""' 0 N OJ "--/ '~ CD 0 OJ CD I n 1") C"~ +~ CJ ~ 0 r~ OJ "--/ c . . W Z 0 I CL u 0 é', :>., E t: ::;¡ r", ,~ u w « 0 :::0 fIl G) 0 z: (f) ---i :::0 fIl fIl ---i BENCH MARK #2 TOP OF OPERATING NUT FIRE HYDANT LOCATED N.E CORNER OF 18TH AND OREGON USGS 765.41 BENCH MARK #1 TOP OF OPERATING NUT FIRE HYDANT LOCATED N.E CORNER OF 16TH AND OREGON USGS 759.22 BENCH MARK #3 TOP OF OPERATING NUT FIRE HYDRANT LOCATED N.E CORNER OF 17TH AND OREGON USGS 760.16 NOT AN OFFICIAL RECORDED DATUM 17TH AVE, O.H. ELEC. ~ r ~p fl ' II ' / EXISTING BUILDING II J /// ~2 S!OR~ WOOD ~RAMED l}PE" VB)/ I Iff U/1~2%R~U: A~'f & R-~ U~IT ~BOV~/ I Ili./ i I ! GAS I I METERS Ii 19 , ~l IT rl . ~ .' 0::: w I- <:( ~ 25' SETBACK PER ZONING ORDNANCE 30-26(3)(C) FRONTAGE SHARED WITHIN fHESAME BLOCK WITH RES. DISTRICT l EXISTING ASPHA~: - - - 25' -0" BUILDIN~ SETBACK- - - - - / / // // // /' / / / H C PARKING SIGN /'.J/'//// .. /~/;.LJ/.'. /'/////// ////, \."",:~-- REMOVE EXISTING SC'REEN PORCH ff f/// ....:L." /" ./ . / / ,. / /' / / ' --l3i.1...1.'. / ,/ / / / / fT <I"'.,tl - - - =- :::::!....- ///.////v./,--"""",. .. I ./ / // / .' / f / / /.~'.¡ . //,// /// i/// // / // //' ,j/ / w:] .,', ' , //// /////'/"'0.'1... , ////'// i/,/'/ ,/,///,/ /.,'-J . /ip/ 6r<n:'O'/~~'f~<>~/<¡/~<';é9 ~1 // /' f\>JP' / ..,;;~~/ // // J/ //. ;'.::<11 /rL</^,'.D lliTlO)bj - - /1//' :;.',:;S',(J " ,LJ::). ........,4/ ',.'."] /</<,</~FIN. FLR ELEV. ~69/~~>---- i + ~ . / i ',/i TY', P.[', 'VB' // /////~~//., '-, . ././//, : 1 DECK /4196; F./////////, I . L:¿j:>:{:¿;;;:;¿ ~ / // /'/' /. ,// //// // / /. // /. ../i ,.1/ / / 1/ /// ..//.',.//./3/ C!:: I., 0/ ,,/ '/1'/ . ,/.// CJ-// -1EMOVE ~X§.TING -IENCI- - -REMOVE EXISTING GARA~E- ., ..---.-:.:...' , ---.:. /" '" ",/ '." """, " . " NEW ASRHALT AREA/ ,65'-0"\ ' .'., I \ I it! Ii II ~: .1 -I I ¡ : ~r ? ¡ I t '-6' t ~ I I I ( I DECK EXISTING I I GARAGE I EXISTING HOUSE I I I north SITE PLAN 1" = 20'-0" PROPOSED GRADE EXIS"TING GRADE ------ I 1 I 1 1 1--1" I I '" I I \ \ \ I / /REM VE TREE I I -- ZONING ORDINANCE ANALYSIS OWNER INFORMATION UJOCJ=r-:LLJZ(/)O zw=::J~zcr::06Z 0« "<:CW~I-(/)« ~ .0 v, = I->-¡Q-.J(J)O«LLJUJ c5mC)D-z--...J:2D-W ~ :2:=000--:=1- LLO==UUJou--...J uWo= °lL.=« WI- r-°z""z(/)wZ CLICJ LL.~r- UJC)==wo uCL ~~LLJI- >-~ 00:::: (/)D-I-wo::::=--...J z>-=oo--:UJ«=> «Cl..8CJ:S=1-(/)0 0 ------=" 0 w >- (/)UiJ2LLJO--:WO--:~O C) LLJVJo Z z~~=~ Cl..=« :>- ~LLJo--:oOLLJ -==-O~=Cl..IO--:=--...J ' ~WLLJ I-Cl..~:::;;(j) Z~I-= ""'-w °:::>(/)0 «W=2(r, =>-t;z=>z LLJ~'-' WOLLJ>-O=~=O::::<C (/) I-<:cI <:CO2 WWQ21->-LLiz: « IO::::= -:>z =0 1-«<:c~=>-«OUI-O ZONING DISTRICT: (C-3) CENTRAL COMMERCIAL DISTRICT LAND USE: INDOOR SALES (MERCANTILE STORE) SURFACE WATER DETENTION REQUIREMENTS REQUIRED UNDER THE FOLLOWING CONDITIONS: IF OVER 3 ACRES IF BETWEEN 1 AND 3 ACRES AND MOR THAN 50% DEVELOPED NO REQUIREMENTS FOR LESS THAN ONE ACRE (PROVIDE GRADING INFO.) SITE SIZE 27900 S.F. .64 ACRES PARKING CALCULATION 1 SPACE PER BEDROOM (2) REQUIRED FOR APARTMENT NON REQUIRED FOR TAVERN IN C-3 BUILDING CODE ANALYSIS PROJECT: BUILDING ADDITION ADDRESS: 1700 OREGON STREET OSHKOSH, WI USE: BAR/ RESTAURANT OWNER: WITZKE'S TAVERN LLC 1700 OREGON STREET OSHKOSH, WI 54902-6924 CONTACT: JOHN RASMUSEN PHONE (920) 231-1925 ~ ~ ~ ~ OCCUP ANCY: A- 2 ,S-1 & R-3 NON SEP ARA TED OCCUPANCY SEPARATION FOR NON SPRINKLERING) TYPE OF CONSTRUCTION: V B (WOOD FRAMED UNPROTECTED) NON- SPRINKLED OCCUP ANT LOAD: 361 (SEE FLOOR PLAN) EGESS WIDTH REQUIRED .2"/, OCCUPANT NON-SPRINKLED .15 '/ OCCUPANT SPRINKLED 460 X..20 = 96" REQUIRED SEE PLAN FOR EXIT WIDTH BY SPACE EXIT ACCESS TRAVEL DISTANCE 200' PER TABLE 1004.2.4 oPP -- ------- TOILET FACILITIES PER TABLE 2902.1 MENS 180 180/75 = 2.4 W.C. 180/200 = .9 LAY. 3 W.C. REQUIRED 1 LA V. REQUIRED UP TO 50% OF TOILETS MAYBE URINALS 1 W.C. 1 U. & 1 LAVS. PROVIDED NEW 1 W.C. EXISTING WOMENS 180 180/75 = 2.4 W,C. 3 W.C. REQUIRED 180/200 = .9 LAV. 1 LA V. REQUIRED 2 W.C. & 1 LA VS. PROVIDED NEW 1 W.C. EXISTING EXISTING VFW CONTROL AREAS NO HAZARDOUS MATERIALS WILL BE STORED PER TABLES 307.7(1) AND 307.7 (2) GRADE PLAN DETERMINATION THE GREATEST HGT. FROM GRADE TO TOP ALLOWABLE HEGHT PER TABLE 503 IS 55' NUMBER OF STORIES (2) THIS BUILDING HAS ONLY THREE FLOOR LEVELS WITHIN THIS BUILDING OF WALL IS 26'-0" L EXISTING ASPHALT TO REMAIN ~ ALLOWABLE AREA PER FLOOR TAVERN USE A2 _110,500 S.F, I (AS CALCULATED BELOW) A =At ~ J+(4&- J 10,500 = 6,000 +~6.0°,oOOX, 75 ) + ~NP 100X 300 J 6,000 S.F. PER TABLE 503 AREA INCREASE CALCULATION PER 506.2 At = TABULAR AREA PER TABLE 503 f = AREA INCREASE DUE TO FRON T AGE AS CALCULATED PER SECTION 506.2 f = 100 tþ - 0.2~ ~O ()50 J 30 .75 = 100 l350 - 0.2j 30 THIS BUILDING ~ ~ ~ ~ ~ ~ ~ ~~~ 0 ú:tc: ~ ~W~ ~~~ ~~~ ~~a ~~O ~ ~ a 0 ~ ~ ~~ ~ ~ ~ a If = AREA INCREASE DUE TO FRONTAGE 350 = F = BUILDING PERIMETER wi 20' OPEN SPACE 350 = P = PERIMETER OF ENTIRE BUILDING 30 = w = MIN. WlDTH OF OPEN SPACE (30 VALUE MAX.) I s =AREA INCREASE DUE TO SPRINKLERS AS CALCULATED PER SECTION 506.3 I s = 200 FOR MULTI STORY BUILDINGS J s = 300 FOR SINGLE BUILDINGS ~ ~ @ ~ ~ ~ a s: DRA WN BY: ..""~_.._"'._".""_."'-_....'.~._".--"-~-""O_.W'."-~'-.woo. FIRE FIGHTING APPARATUS THE BUILDING IS LIMITED IN AREA THE FIRELANE IS UNOBSTRUCTED THE FIRELANE IS WITH IN 150 ' OF ALL PARTS OF THE EXTERIOR WALL THE BUILDING IS LESS THAN 30'-0" TALL THE FIRELANE OF 20'-0" MIN. WIDTH EXTENDS THIE LENGTH OF THE HIGHER BAY WITH A MIN. UNOBSTRUCTED HIEGHT OF 13'-6" RJF CHK'D BY: -"""".""".'_.""'._'-.'.."~'."--"""'-"""--".~"._~_.""'..""._".._.". RJF JOB NUMBER: """"'.-.".'..""",."."",....,..-.".,..,......",.."."..,-"".""'.""".."'.'..."..."".'.""""".-."'. 03042 DATE: ."".""-..""."",."""",.",,"..,,,,. "-.",, """.."""-."'."."'- .""..""_."".,,."...,. 5/30/03 (Ç}rû 0 U