Loading...
HomeMy WebLinkAbout0113029-Building (wall sign) e OSHKOSH ON THE WATER Job Address 300 N MAIN ST CITY OF OSHKOSH No 113029 BUILDING PERMIT - APPLICATION AND RECORD Owner BANK ONE OSHKOSH N A Create Date 03/08/2005 Designer Contractor APPLETON SIGN COMPANY INC Category 254 - Signs Plan Type 10 Building . Sign 0 Canopy 0 Fence 0 Raze Zoning Class of Const: Size Unfinished/Basement 0 Sq.Ft. Rooms 0 Height 0 Ft. Finished/Living ~ Sq. Ft. Bedrooms 0 Stories Garage ~ Sq. Ft. Baths 0 U Projection I Canopies 0 Signs 0 Foundation . Poured Concrete 0 Floating Slab 0 Concrete Block 0 Post 0 Pier 0 Treated Wood 0 Other Occupancy Permit Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures 0 new wall sign, "CHASE", to replace "BANK ONE" Use/Nature of Work HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $10,700.00 Plan Approval $0.00 Permit Fee Paid $79.00 Park Dedication $0.00 Issued By: Date 03/15/2005 Final/O.P. 00/00/0000 U Permit Voided I Parcelld # 0200760000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address 2400 HOllY RD Agent/Owner NEENAH WI 54956 - ~ Telephone Number 920-734-1601 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. . Signchart ~lerl()-,_R~~mendation~- -. Exisiting Signage Sign: No: 001 Sign Type: Pylon Face Material: ~~;~~d Graphic Material: Vinyl Height: 64" Width: 180" Depth: 14" Overall Above Height: 233" Illuminated: :~~%~~~Ired Electrical Electrical: Power within 8' Wall Material: none Proposed Signage Action Code: Reface G3-P50- TFO 18'-5" Pylon (Face Only -see control docs) Sign Type: Description: Required Site Work Message Face A: Message Face S: Restoration: 2003 G3 Sign Family Retrofit FACE ONLY PRODUCT. Field verify existing conditions meet this criteria. See control documents for product modification requirements. Comments: !zJo A/¿~fI- 7J11jL~ Ú¿;A~ -~-{Û¡] 0 0 Page 4 onl Site Number: 515832 ¡Ol $1 Replace Face Only 'See lasTpagè"Fõ,Tegal bisëlaimer Monigle Associates. SignChart http://www.signchart.com/chase/print/print- eng.asp?site _id=3529 1/27/2005 , Signchart Page 6 of 31 Exterior Recommendations - --------- - --------------------- - Site Number: 515832 - -------------- Exisiting Signage Sign: No: 003 Sign Type: Channel Letters Face Material: Flat Plastic Graphic Material: Vinyl Height: 42" Width: 192" Depth: 6" Overall Above Height: 480" Illuminated :~~%~~~{ed Electrical: ~i~~i~i~~1 Power Wall Material: none Proposed Signage Action Code: Sign Type: Description: Remove/Replace LlF-WBO-24-T 24" White ~t1.-'+/- illuminated channel letters w/ blue octagon Required Site Work Message Face A: Message Face B: Restoration: Patch and repair existing wall surface to like new condition. Repaint to match existing color finish. For brick or stone walls fill holes with matching silicone. Power wash wall if required. Install new signage using existing primary electrical. Verify if additional circuits are required for new sign. Field verify dimensions of space shown in photo morph prior to fabrication to verify if specified letterset will fit in area and meet clear zone tolerances - refer to Control Documents. ".Change letterset height if required. See control documents for product specification and master agreement for removal & installation requirements. Comments: http://www.signchart.com/chase/print/print_eng.asp?site -- id=3529 1/27/2005 -, < Signchart Page 7 of3! Site Number: 515832 -----------------.....--------- ---_.-------------------_.---. Exterior Recommendations Exisiting Signage Sign: No: 004 Sign Type: Wall Cabinet Face Material: Fonmed Plastic Graphic Material: Vinyl Height: 48" Width: 144" Depth: 10" Overall Above Height: 202" Illuminated :~~%~~~red Electrical: ;,ri~~i~i~~1 Power Wall Material: none Proposed Signage Action Code: Sign Type: Description: Remove/Replace LlF-R-WBO-16 16" White illuminated channel letters wi blue octagon (mounted on a raceway) Required Site Work Message Face A: Message Face S: Restoration: Patch and repair existing wall surface to like new condition. Repaint to match existing color finish. For brick or stone walls fill holes with matching silicone. Power wash wall if required. Install new sign age using existing primary electrical. Verify if additional circuits are required for new sign. Field verify dimensions of space shown in photo morph prior to fabrication to verify if specified letterset will fit in area and meet clear zone tolerances - refer to Control Documents. ...Change letterset height if required. See control documents for product specification and master agreement for removal & installation requirements. Comments: Install on raceway - paint raceway to match existing building surface. http://www.signchart.com/chase/print/print_eng.asp?site - id=3529 1/27/2005