Loading...
HomeMy WebLinkAbout0113039-Building N 0 II. (I" II) 0 II) \0 (I" N 0 N 0\ U 4- a +' a. Q 0 .r: III a .::J. .r: III 0 4- a 5* ~~ùL ~ ¡ÎMi /) (I" 0 '3-)-é)l)" .. II) 0 I ,., 0 , ~ r¡ :E 'c\'é:.\O\ 'c\þ.\I~~ O~. 1165 Heidi Haven Dr. Lot 115 2nd Add'n to Pheasant CreeR Farm N .+. s ~ OJHKOfH 10 20 30 Feel 1 inch equals 20 feet DISCLAIMER Thl' map' """e< 3"""', ",co«le; map"", a ,"N"y an.'. "01 """""ob" ".. as ..". Th..""" , a ""p'aU.. 0' "",..<Is. .a~ """'efonnalloelo"".."""'"W.",,,eW aed '~leolf~""olhe"""""'31fe'tle. the..., """"", ""obe."'.'o"""""",,, PU"",'Kon/y. The Cilyo'Oshko"'~not ",'poe.ÞIe "" eoy ;e"""",¡", '",e. "",..Ie.. 1I""'",paec""""'"",~""""e~"Ih. City 0"""1"" Source: City of Oshkosh G.I.S. Tuesday, March 01, 2005 .¡:; / ~ OfHKOfH ON m, W,,"' City of Oshkosh Division ofInspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 Office 920-236-5050 Fax 920-236-5084 PLAN REVIEW Project Address: 1165 Heidi Haven Dr Submitted By: Rusch Homes LLC Plan Number: GI-003-0305 Reviewed By: Brian Noe Phone: 236-5051 Date Reviewed: March 8, 2005 Result of Plan Review: D Mailed D Faxed IZI Delivered with Permit IZI Conditionally Approved D Withheld Pending Approval of Additional Information D Not-Approved, Plans Returned for Revisions Conditions Noted on Plan Review 1. 21.04 Effective 1/1/05 Guardrail opening size has been changed to a maximum of 4 inches. 2. 21.02 Complete truss plans and layout are required to be onsite at time ofrough inspection 3. 21.09 Smoke detectors are required to be provided in each bedroom and adjacent to all sleeping areas. (2"d floor hall may require 2 due to bedroom separation) 4. Comm 21.25(1)(b) Bracing. Exterior walls shall be braced at the corners. 1. Nominal 1 inch by 4 inch continuous diagonal members set into the face ofthe studs at an angle between 45° and 60°; or 2. Four feet by 8 feet plywood sheathing panels not less than '/,,-inch thick for 16-inch stud spacing and not less than '/. inch thick for 24-inch stud spacing; or 3. Preformed metal T-bracing not less than 22 gage (.0296 inches) thick and 1'/, inch wide; or 4. Other approved wind bracing materials. (Caution on wall design at single overhead door) 5. No structure is permitted within any Easement located on the property. 6. Provide structural calculations / framing detail for 2 story walls with large openings on the comer of the rear ofthe house. 7. 21.05 Safety glass is required in sidelights adjacent to door 8. 21.02 Point loads must transfer properly - Caution on bearing requirements for beams. 9. The drainage will be required to be completed in compliance with the approved grading and drainage plan. The submittal described above has been reviewedfor conformance with the State of Wisconsin Uniform Dwelling Code. The submittal has been CONDITIONALLY APPROVED. This is a limited review, Ultimately it is the applicant / owners responsibility to comply with all applicable cJdes. statues and ordinances, and the conditions of this approval, 165 Dr Page I of2 /,~ 10. Heat loss calculations are required to match the actual construction. 11. Garage spaces shall be separated ITom dwelling unit in accordance with Corom 21.08.- The door and ITame assembly between the dwelling unit and an attached garage shall be listed an labeled by an independent testing agencv ( j.e, UL, ETL, WH, ) as having a minimum fire-resistive rating of 20 minutes. ALL drywall joints are required to be taped / sealed unless the joints are fitted so that the gap is no more than 1/20th of an inch (a dimes thickness) and backed by solid wood or drywall with joints staggered. 12. All Penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in studs used for return air spaces. 13. The property owner and applicant is responsible for compliance with Corom 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required for a minimum 6 inch depth, 14'-20' wide, and 30' -50' in length. Erosion control measures are required to be maintained until the permanent lawn has been established. 14. All storm sewer inlets must be protected with approved erosion control devices. Tracking (sediment) must be removed ITom the street at the end of each work day. Repair of any siltation, or erosion damage to adjoining surfaces and drainage ways resulting ITom land development or disturbing activities. 15. All site grading must be done in accordance with the approved drainage plan on file in the public works office -located on 3rd floor 'ty all. s ~ of A Þ Þ /.ú;ant': tJat1Y. The submittal described above has been reviewedfor conformance with the State of Wisconsin Uniform Dwelling Code, The submittal has been CONDITIONALLY APPROVED, This is a limited review. Ultimately it is the applicant / owners responsibility to comply with all applicable codes, statues and ordinances, and the conditions of this approval. Page 2 of2 .__.~