WISCONSIN INDUSTRIAL COMMISSION
PLAN FI LE ',-C.,ot
Division of Industrial Safety & Buildings
1 ~!est Hi lson Street DATE~ ,"""'.
Madison, ~!isconsin I)
'6'-1' VJ
NAME AwK.." -,tilt swty ...,
ADDRESS 188 VIó ,.., .. fM ...
NI'.....- 10. VI....'"
Re:
.t~)
\'" '\
PcP
¡';P
Heating and Venti lating Drawings for: lilt".... Oøìhtt
"""1' Aø~ (12) ., Rom.. Auø. WMt .... ~
01... 1iIt...f.,
This;is to confirm that the plans for the above project have been examined
and the proposed installation appears to conform with minimum code requirements,
except for the items checked a~ follows:
-!.1.
_2.
_3.
- 4.
_5.
_6.
_7.
- 8.
- 9.
_10.
No except ions.
Controls shall be provided so that not less than the minimum air supply
and exhaust be maintained during periods of occupancy. See Ind 58.22(7)
Provide tempered outside air supply.
Ind 58.41
See Ind 58.24(7), Ind 58.40,
Provide exhaust ventilation.
See Ind 58.48, Ind 58.49, Ind 58.52
The design and construction of airways.
See Ind 58.69
Kitchen range hoods and ducts connected to range hoods.
See Ind 58.49
Installation of unit heaters, suspended furnaces and duct heaters,
See Ind 58.66
Provide furnace room enclosure. See Ind 54.13, Ind 55.29, Ind 56.15,
Ind 57.20, Ind 57.50
Outside air intake.
See Ind 58.60
Other exceptions:
/)
/Í- //\::::.c;)r¿..c,-<~_~.¿~..ÁJ
N. Bo 11 enbach
Assistant Building Engineer
NB:flj.a .
. ~'1IeMY '- ....,
yet-If. I.. ..,...... a,.. ,--,.
"./
~.
STATE OF WISCONSIN
INDUSTRIAL COMMISSION
I
liaY 13, 196)
INDUSTRIAL SAFETY & BUilDING DIVISION
1 WEST WILSON STREET
MADISON 2, WISCONSIN
Award Engineering. Inc.
i 1602 W. North Avenue
~a~tos.. Wisconsin
Re:
Bet ry and Q,uant Apartment #3
West Second Avenue, Apartment located
on East end of lot (lot has room for "2
apartments tout area) Oshkosh
Plan File 63-C.513
Gent1emen:
Bul1,Hng plans for abov.~ project have been stamped "Conditionally Appreved -
See ~orrespondenc~' and Z sets of plans were return~d. One stamped group of
plans shall be kept at the bullØir'9 site during cOflStruction Ind 50.H.
Additional plan covering heating and ventilating will be necessary.
lAd 53.28. Buildings shall be anchored to foundation to resist wind lifting
force. Solid bridging Is required the tul) depthof the joist wher~ they pass
over bearing partitions. All openings shall be fr&w~d with double studs and
double headers and trussed when OVer 4 feet. Double joisa shall used ¡¡nder
partitions or solid bridging 16 inches on center.
Ind 53.10. 13 geu'ge tIes 18 Il'IChes vertic.lly and 36 inches horlzonta1ly are
~qu¡red for brick veneer.
/.I11d 51.15(3), exit door hardwiifre as specified by this section.
Ind 53.06. A ¡¡it or manuf'acttjr.,rs fur"lshlng b1ock and brick shall b" for-
warded in order to check with approved ¡¡st.
Ind 51,16. Hand~ls shall be on the left hand side as one mounts the stairs
and on the open side if any. Distance 2 foot 6 Inches minimum above the nose
of the treads. All stairways shall have. maximum rise of 7.3/4 Inches and
a minimum tread of 9.112 inches. The outside step shaH not be OV(\r 7-3/4
Inches below the door 511 I.
Ind 53.28(9), Wood bearing on bUe!llent floor shall be 3 Inches above,elther
'\ on brick, block or COl'\crete.
" ...I.\~'
"øj<'1 \' Ind 57. IS. Wlnc:lows ¡;ollvfll;; room shall have a minImum of 5~~ of floor ,¡¡re<l
~ 1< -.[<5" openabie.
\@ß .
ð'V
Ind 57.15(1). In order to comply with the row house classification with the
5/8 fire code gypsUIII board shall be continuous from I118SQ11ry basement wall to
the undersIde of the reof boards vertically and horizontally from sheathIng
11'1 the front of .bÌJ:¡ ¡ding.
Award Engln.ørlng. Inc.
Wa\Måtos.. Wisconsin
S1J3/63
.2~
(2) (d). E"ch unIt shall have access to tha attic with., miniMUm of 20 by 30
In.::h opening above the stair landing.
Ind 52.10. No wood shall be placed closer t}-",i\ 1 Inches fl'OllltÎ\e Outsl.
surface of the chimney and the space between fl Ited with IncQltlbllstlble
meterlal. ChllMeys shalt be bunt of solid masOl'lI)' with" fhiè. tin.,. (8
Inch solid chimney will not require flue liner and 4 Inch solid requires
flue Iln.r).
PI84se In the future ~echøck your arithmetic 01'1 the calculations. Here again
as In your other calculations I have found that yOU hive mede .~~ error In
Yollr arltl'¥flljlt;lc. Please recheck. Your I beam, ht>wever. "'-S the necessary
seçtlOl'llftOdulas as with corrected calculations It would c;ome out In the
nßlghborhood of 1+ Inches cubed and not 1.52 Inches cubed as your calculatlOl'ls
show b¡¡t the sectlOl'l prO'lI.d Is 7.3 inches cubed lilhlc;h Is sath.factory.
Very truly 'fours.
ROGER OSTREM. 'ØIRECTOR
þ,~
; ~Á.~
~ø rJ"u
IiI.,P: esw
eel .Deputy Van Handel
.~etl!ler. IIldg. Insp.
Oshkosh
a.:-M
Walter J. P_II
Asst. BuildIng EngIneer
./