HomeMy WebLinkAbout0099677-BuildingOSHKOSH
ON THE WATER
JobAddress 3222 BELLFIELD DR
Designer
Category 110 - New Single Family
CITY OF OSHKOSH
BUILDING PERMIT -APPLICATION AND RECORD
Owner CREATIVE CUSTOM HOMES
Contractor CREATIVE CUSTOM HOMES, INC
Type · Building O Sign O Canopy O Fence O Raze
No 0099677
Create Date 01/02/2003
Plan D1-184-1202R
Zoning Class of Const: 8
Unfinished/Basement 805 Sq. Ft. Rooms 7
Finished/Living 1778 Sq. Ft. Bedrooms 4
Garage 528 Sq. Ft. Baths 3
Foundation · Poured Concrete O Floating Slab O Pier
O Concrete Block O Post O Treated Wood
Occupancy Permit Required Flood Plain No
Park DedicatiOn Required # Dwelling Units 1
Height 23 Ft.
Stories 2
Other
Size IRRG
[] Projection
Canopies
Signs
Height Permit Not Required
# Structures 1
Use/Nature qSFR/ New single family 2 story with 2 car attached garage. NO DECK OR PATIO. Driveway will be 20' wide.
of Work
HVAC Contractor
Electric Contractor
Fees: Valuation
Issued By:
BAY AREA SERVICES INC
VAN ERT ELECTRIC
Plumbing Contractor HANSON QUALITY PLUMBING
$100,400.00 Plan Approval $75.00 Permit Fee Paid
$383.00 Park Dedication $100.00
Date 02/03/2003 FinallO.P. 00/00/0000
[] Permit Voided
In the performance of this work I agree t_o perform all work pursuant to rules governing the described construction.
Signature 9&~/'~'.~/~'~ Date ~)~,~--~"-
.... ~/ Agent/Owner
Address 1087 VELP AVE GREEN BAY WI 54303 - 0000 Telephone Number 434-4105
OSHKOSH
ON THE WATER
GRADE STAKE FORM
Name CREATIVE CUSTOM HOMES Address
Lot 59 Block
Subdivision 1ST ADD"I' VILLAGE GREEN Zone
Street Number Lot Dimensions
3222 BELLFIELD DR
Grade Stake Number 6869
Create Date 01/02/2003
L_J Sidewalk Existing J
Ward
Building Grade Elevation Stakes Set At Site 01/06/2003 Set By D.W.G. BK - 579, P - 58
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation
has commenced.
,Wisconsin Department of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
[] Constr
Owner's Name
CREATIVE CUSTOM HOMES
Contractor: L~J Con~] Elec'~ HVAC ~J Plbg
CREATIVE CUSTOM HOMES, INC
Contractor: L_J Con ~j Elec [~ HVACL_J Plbg
VAN ERT ELECTRIC
Contractor: b__J Con ~ Elec~J HVAC [] Plbg
BAY AREA SERVICES INC
Contractor:L~ Con [] Elec~_.J HVAC[] Plbg
HANSON QUALITY PLUMBING
Lot Area
Building Address
3222 BELLFIELD DR
WISCONSIN UNIFORM
BUILDING PERMIT
APPLICATION
Application No.
[] HVAC [] Elec [] Plbg [] Erosion [] Other:
Mailing Address Telephone No.
1087 VELP AVE GREEN BAY WI 54303 - 0000
Lic/Cert #
679085
Mailing Address
1087 VELP AVE
Telephone No.
434-4105
Telephone No.
920-766-3888
GREEN BAY WI 54303 - 0
Lic/Cert # Mailing Address
170921 2000 PROGRESS WAY . KAUKUANA WI 54130 - 0
Lic/Cert # Mailing Address Telephone No.
5180 1449 S BROADWAY GREEN BAY WI54304 -0 920-435-7111
Lic/Cert #
Mailing Address
550 N BLUEMOUND RD
APPLETON WI 54914 -0
Scl. ft. 1/4, 1/4,Section ,T N,R E(or)W
Subdivision Name ~ Lot No. Block No.
1ST ADD'T VILLAGE GREEN 1 59
Telephone No.
730-0205
Zoning District(s) I Zoning Permit No. Front Rear Left
etbacks I ff. I ff. I ff.
L~ New [] Repair
[] Alteration [] Raze
[] Addition
[] Move
[] Other:
Size: 200 am
Service:
i[~ Overhead .
i[] Underground
Right
I[] Single Family I Entrance Panel I b~J Forced Air Furnace I _ . I Nat. I L.P.I OillElec. I Solid lSola
[] Radiant Baseboard or PanelI I-ue! Gas~ *
[] Heat Pump I Space Htg []/[]I- 1 [] I [] I []
[]~ Boiler WaterHtgl []/I---I II~l []1[]1[]
Centra A r Conditioning * L_J Dwelling unit will have 3 kilowatt or
Two Family
Garage
Other (print):
more installed electric space heating equip.
[] Site Constructed Concrete Infiltration control option is: [] Full sealing
Unfinished [] Manufactured Masonry
Treated Wood Sewer of joints. [] Blower door test. [] Exterior
Basement 805 Sq. ft. [] Municipal air infiltration barrier.
Living Area 1778 Sq. ft. 1-Story Other [] Septic
Garage 528 Sq. ft. I ~ 2-Story Permit No. Envelope 28320 BTU/HR
Other [] Seasonal Infiltration 16169 BTU/HR
I
[] Permanent
Plus Basement [] Other
[] Municipal Utility
[] Private On-Site Well
$126,900.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, ex.l~.e,s~or implied, on,,~he D~partment or municipality; and certifies that all the above information is accurate.
APPLICANT'S SIGNATURE ~~~ ~/~,~__~ DATE SIGNED Z;),~ '"~'~"~:),~
This permit is iss~purSuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS revocation of this'permit or other penalty
SEE "STANDARD CONDITIONS OF APPROVAL" SHEET
[] Town [] Village [] City [] County L~ State of: Municipality Number of Dwelling Location:
City Of Oshkosh 7 0 - 2 6 6
Plan Review $75.00 Construction
HVAC Name JZ
Inspection Electrical
Wis. Permit Seal $30.00 [] Plumbing Date 1/2/03
Other [] Erosion
Total $105.00 275790 Cert. No. 70330
SBD-5823 (R. 07/92)
OSHKOSH
ON THE WATER
Job Address 3222 BELLFIELD DR
~ Name CREATIVE CUSTOM HOMES
Address 1087 VELP AVE
Subdivision 1STADD'TVILLAGE GREEN
Building Permit Number 0099677
Number of Dwelling Units 1
Fee Required $100.00
Owner's Signature
Inspector's Signature
PARKLAND DEDICATION FEE COLLECTION RECORD
Date 02/03/2003
GREEN BAY WI 54303
Lot 59
Number of Structures
Fee Paid
Date
Date
CITY OF OSHKOSH
CONDITIONS OF APPROVAL'
Project Address ~ "' ~permit#
Please read the following information and sign at the bottom to acknowledge that you have read
and agree t° comply with these. conditions.
1. All habitable rooms must be Bedrooms
located on the ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas~ in accord~ar!?e~.?i~
2. ' Garage spaces shall be separated from the dwelling unit in
The door and frame assembly between the dwelling unit and an attached garage shall be
: labeled by an independent testing agency as having a minimum fire-reSistiVe rating Of 20
minutes. All'drYwall joints are required to be taped/sealed Unless the j°ints are fitted so
that the gap is no mOre than a dimes thickness (1/20-inch) and backed by solid wood or
drywall with the joints staggered.
3. All penetrations in exteriOr Walls
includes holes in the top and bottom plates, gaps around heating ducts¢ and holes in the
retUrn air spaces.
4. Smoke detectorsare required on every ~ within 6' of all bedrooms.
detectors are reqUired t° be hardwired and interconnected.
5. Hydromassage tUbs are required to have an access panel to' m0t0r~~' The access panel must
be accessible without removing the finish of the house.
o
All overframing must be designed by the truss manufacturer, according to standards set
by the truss' Plate institute, or Structural Calculations must be Provided prior to the rough
building inspection.
Truss plans must be submitted ~an._d approved prior to framing the roof.
8. Truss plans including the tress layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough bUilding inspection for all microlams with point loads on them.
9'.~' C~i~tflationS must be provided for ill ~antilevere~l'f/~)0r§ with point loads. Floor trusses
and TJI's mUst be designed for the cantilevered areas.
10.
11.
12.
13.
14.
15.
16.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintained until the lawn is esmbl~o~!~e.~.
All storm seWer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work o~ders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged.
Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must b~c.~gmpleted to avoid the $100 re-inspection fee per inspection.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
Place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
The building placard must remain on the patio door or on a kitchen window until~ ...........
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further no~i~.b~ing
given.
17.
All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.
~o~H