HomeMy WebLinkAbout0099674-BuildingOSHKOSH ON THE WATER Job Address Designer Category Type 3218 BELLFIELD DR 110 - New Single Family CITY OF OSHKOSH No 0099674 BUILDING PERMIT - APPLICATION AND RECORD Owner CREATIVE CUSTOM HOMES Create Date 01/02/2003 Contractor CREATIVE CUSTOM HOMES, INC Building O Sign © Canopy O Fence O Raze Plan Dl-183-1202R Zoning R-1 Unfinished/Basement Finished/Living Garage Foundation Occupancy Permit Park Dedication Class of Const: 8 1453 Sq. Ft. Rooms 4 1453 Sq. Ft. Bedrooms 3 576 Sq. Ft. Baths 2 · Poured Concrete O Floating Slab O Pier O Concrete Block O Post O Treated Wood Required Flood Plain No Required # Dwelling Units 1 Height Stories Other 16 Ft. Size IRR [] Projection Canopies Signs Height Permit Not Required # Structures 1 Use/Nature qSFR/New single family 1 story home with a 2 car attached garage, NO DECK OR PATIO. of Work HVAC Contractor Electric Contractor Fees: Valuation Issued By: BAY AREA SERVICES INC VAN ERT ELECTRIC Plumbing Contractor HANSON QUALITY PLUMBING $89,900.00 Plan Approval $75.00 Permit Fee Paid $350.00 Park Dedication $100.00 Date 02/03/2003 FinallO.P. 00/00/0000 [] Permit Voided In the performance of this work I agree to perform all work pursuant to rules governing the described construction. Signature ,~~~ ~~ Date ~:)~~'~.~  Agent/Owner Address 1087 VELP AVE GREEN BAY WI 54303 - 0000 Telephone Number 434-4105 OSHKOSH ON THE WATER Name CREATIVE CUSTOM HOMES GRADE STAKE FORM Address 3218 BELLFIELD DR Lot 60 Block Subdivision 1ST ADD TI VILLAGE GREEN Zone Street Number Lot Dimensions Grade Stake Number 6865 Create Date 01/02/2003 LL Sidewalk Existing Ward Building Grade Elevation Stakes Set At Site 01/06/2003 Set By D.W.G. BK - 579, P - 56 Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. ~ Wisconsin Department of Industry, Labor and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 Owners Name CREATIVE CUSTOM HOMES WISCONSIN UNIFORM BUILDING PERMIT APPLICATION Application No. [] Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other: Mailing Address 1087 VELP AVE Telephone No. GREEN BAY WI 54303-0000 819-4396 Contractor: ~ Con~--~ Elec'[~ HVAC ~ Plbg CREATIVE CUSTOM HOMES, INC Contractor: ~ Con b~ Elec~ HVACL_j Plbg VAN ERT ELECTRIC Contractor: [_J Con ~J Elec]~ HVAC [] PIb.c BAY AREA SERVICES INC Contractor: b_J Con [] Elec[~ HVAC[] Plbg HANSON QUALITY PLUMBING Lot Area Lic/Cert # Mailing Address Telephone No. 679085 1087 VELP AVE GREEN BAY WI 54303 - 0 434-4105 Lic/Cert # Mailing Address Telephone No. 170921 2000 PROGRESS WAY KAUKUANA WI 54130 - 0 920-766-3888 Lic/Cert # 5180 Mailing Address 1449 S BROADWAY Telephone No. 920-435-7111 GREEN BAY WI 54304 - 0 Lic/Cert # Mailing Address Telephone No. 550 N BLUEMOUND RD APPLETON WI 54914 -0 730-0205 Scl. ft.I 1/4, 1/4,Section ,T N,R E(or)W Building Address I Subdivision Name Lot No. I Block No. 3218 BELLFIELD DR ~ 1ST ADD TI VILLAGE GREEN 60 I Zoning District(s) Permit No. Front Rear Left Right New [] Repair Single Family Entrance Panel Forced Air Furnace Fuel Two Family Size: 200am [] Radiant Baseboard or Panel [] Alteration [] Raze Garage IService: -- [] Heat Pump Space Htg [] Addition [] Move [] Other (print): I[--] Overhead [] Other: JE~ Underground [] Boiler Water Htg Central Air Conditioning~ Dwelling unit will have 3 kilowatt or more installed electric space heating equip. [] Site Constructed Concrete Infiltration control option is: [] Full sealing Unfinished [] Manufactured Masonry Sewer of joints. [] Blower door test. [] Exterior Treated Wood Basement 1453 Sq. ft. [] Municipal air infiltration barrier. Living Area 1453 Sq. ft. 1-Story Other [] Septic ~_~_~__] 2-Story Permit No. Envelope 29823 BTU/HR Garage 576 Sq. ft. Other [] Seasonal Infiltration 17785 BTU/HR [] Permanent [] Municipal Utility Plus Basement [] Other [] Private On-Site Well $144,900.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, exp~.,~r implied, o,~t~ De.~rtment or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE ' ~! Jg~,,~/P' ,~",~',~,~¢~ DATE SIGNED Thi; permit is issue~rursuant to the following conditions. Failure to comply may result in suspension or APPROVAL CON DITIONS revocation of this permit or other penalty SEE STANDARD CONDITIONS OF APPROVAL [] Town [] Village [] City [] County [~ State of: Municipality Number of Dwelling Location: CityOf Oshkosh 7 0 - 2 6 6 Plan Review $75.00 Construction HVAC Name NICOLE KRAHN Inspection Electrical Wis. Permit Seal $30.00 [] Plumbing Date 1/2/03 Other [] Erosion Total $105.00 275776 Cert. No. 248101 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER Job Address Name Address Subdivision Building Permit Number Number of Dwelling Units Fee Required PARKLAND DEDICATION FEE COLLECTION RECORD 3218 BELLFIELD DR CREATIVE CUSTOM HOMES 1087 VELP AVE 1ST ADD TI VILLAGE GREEN 0099674 1 $100.00 Owner's Signature Inspector's Signature Date 02/03/2003 GREEN BAY WI 54303 Lot 60 Number of Structures Fee Paid Date Date CITY OF OSHKOSH STANDARD C ONDITIO N S OFXPPR-OVXL Project Address ~\~c~ ~~~ Permit # Please read the following information and sign at the bottom to acknowledge '(hat you have read and agree to comply with these conditions. All habitable rooms must be provided with 8% light and 3~5% Yefitilation. Bsdf66ms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 2L-037 Garage spaces shall be separated from(he dWelling unit in acc0rdanCewiLh'iLHR~"2l~0K The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire:rssis-ti~e rating of 20 ' minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and backe~l by's61id Wood or drywall with the joints staggered. Ail penetrations in exterior walls must be sealed prior to the insulation inspeCtiOn. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. Smoke detectors are required on every floOr and within 6' of all'bedfO0'mS.'The'smoke detectors are required to be hardwired and interconnected. Hydromassage tubs are required to have an aCCeS~ be accessible without removing the finish of the house. All overframing must be designed by the truss manufacturer, according to standards Set by the truss plate institute, or structural calculations must be prOvi~ted pri-or-io'(he~i~6ugh building inspection. 7. Truss Plans must be submitted and approved prior to framing the rO6f~ Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. Calctilations must be provided for all'cantilevered 'fl0bi-S With point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintained until the lawn is established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the~end Of each Workday~ 'Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. -Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals must be roughed in prior to requesting'the rough building insPeCtion. If on the inspection the mechanicals are not roughed in, the inspeCtion will fail and a $100 re-inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At'the fiiihl inspection ail'it~ffiS 0n this list must be completed to avoid the $100 re-inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is readv. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided.around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances sUCh as the stove, refrigerator, washer; and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor. G ~A V~L