Loading...
HomeMy WebLinkAbout0098538-BuildingOSHKOSH ON THE WATER ,Job Address 3730 PURPLE CREST DR Designer CITY OF OSHKOSH BUILDING PERMIT -APPLICATION AND RECORD Owner DEWEY HOMES Contractor DEWEY HOMES INC Category 110 - New Single Family Type · Building O Sign O Canopy O Fence O Raze No 0098538 Create Date 10/30/2002 Plan D1-164-1002R Zoning R-2 UnfinishedlBasement Finished/Living Garage Foundation Occupancy Permit Park Dedication Class of Const: 8 1120 Sq. Ft. Rooms 5 1120 Sq. Ft. Bedrooms 2 528 Sq. Ft. Baths 2 · Poured Concrete ~) Floating Slab (~ Pier O Concrete Block O Post O Treated Wood Required Flood Plain No Required # Dwelling Units I Height 17 Ft. Stories 1 Other Size Irrg [] Projection Canopies Signs Height Permit Not Required # Structures 1 Use/Nature NSFR/ New single family, 1 story, 2 car attached garage, 12' x12' PATIO, 20' wide driveway. of Work HVAC Contractor Electric Contractor Fees: Valuation Issued By: ' ~--.V~ r-- AMERICAN HEATING & A C CO CUMINGS ELECTRIC Plumbing Contractor P&S PLUMBING $76,500.00 Plan Approval $75.00 Permit Fee Paid [] Permit Voided $311.00 Park Dedication $100.00 Date 11/11/2002 Final/O.P. 00/00/0000 In the performance of_t~ I agr_ee_t~, perform all work pursuant to rules governing the described construction. R~~ES~TD Agent/Owner Address 3876 PU R OSHKOSH WI 54901 - 8212 Telephone Number 920-231-3389 OSHKOSH ON THE WATER GRADE STAKE FORM Name DEWEY HOMES Address Lot 39 Block Subdivision Meadows North Zone Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site 10/31/2002 Set By 3730 PURPLE CREST DR D.W.G. BK- 579, P - 69 Grade Stake Number 6849 Create Date 10/30/2002 Ward L~ Sidewalk Existing Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the ~ established before excavation Wisconsin Department of Industry, La6or and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 [] Constr Owner's Name ................................................. DEWEY HOMES Contractor: L~J ConT'-] Elec[] HVAC ~J PIbg DEWEY HOMES INC Contractor: L__J Con ~ ElecL_J HVAC]_J PIbg CUMINGS ELECTRIC WISCONSIN UNIFORM BUILDING PERMIT APPLICATION  Application No. 38 [] HVAC [] Elec [] Plbg [] Erosion [] Other: Mailing Address Telephone No. 3876 PURPLE CREST DR Oshkosh WI 54901 - 0000 Lic/Cert # Mailing Address Telephone No. 250178 3876 PURPLE CREST DR OSHKOSH WI 54901 - 8212 920-231-3389 Lic/Cert # Mailing Address Telephone No. 170792 PO BOX749 1414 COUNTY RD JJ NEENAH WI 54957 - 749 231-5946 OSHKOSH WI 54902 Contractor: ~j Con ~_~ ElecL~_j HVAC [] Plbg Lic/Cert# Mailing Address ~pC&S PLUMBiNGMERICAN HEATING &ACCO i6356 1129 MICHIGAN AVE ontractor:J I Con ~ Elec[] HVAC[] Plbg ILic/Cert # Mailing Address I ,~O BOX 2153 Lot Area Sq. ft. Building Address I Subdivision Name 3730 PURPLE CREST DR I Meadows North District(s) Permit No. Telephone No. - 6437 (920) 235-8090 Telephone No. APPLETON WI 54913 - 0 734-3912 1/4, 1/4 ,Section ,T N, R E(or)W ILot No. I Block No. I 39 IFront Rear Left Right Unfinished Basement 1120 Sq. ft. Living Area 1120 Sq. ft. Garage 528 Sq. ft. [] Site Constructed Concrete [] Manufactured Masonry ~ [] Treated Wood 'r~"'";i"~ .................................. [] Other [] 2-Story ~ [] Other [] Seasonal [] Permanent [] Other [] Plus Basement Other g unit will have 3 kilowatt or Sewer [] Municipal [] Septic Permit No. [] Municipal Utility [] Private On-Site Well of joints. [] Blower door test. [] Exterior air infiltration barrier. Envelope 19253 BTU/HR Infiltration 13709 BTU/HR $90,000.00 IThe applicant agrees to comply with all applicable codes statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express or i0~ffl'~d, on t_J3e Depaj~j~r~'~ municipality; and certifies that all the above information is accurate. APPI~r3VA/~l~ll31TInl~l.~' ~ '~-- "~'¢r~is i~ermit is is~/k~rsuant to the following conditions. Failure to comply may result in suspension or ....................... revocation of tt~p'ermit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET [~Town [] Village [] City [] County L_J State of: City Of Oshkosh Municipality Number of Dwelling Location: 7 0 2 6 6 Plan Review $75.00 Construction HVAC Name JOHN ZAP, ATE Inspection Electrical Wis. Permit Seal $30.00 [] Plumbing Date 1 1/1/02 Other [] Erosion Total $105.00 -~ 275829 Cert. No. 70330 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER PARKLAND DEDICATION FEE COLLECTION RECORD Job Address 3730 PURPLE CREST DR Date 11/11/2002 Name DEWEY HOMES Address 3876 PURPLE CREST DR Oshkosh WI 54901 Subdivision Meadows North Lot 39 Building Permit Number 0098538 Number of Dwelling Units 1 Number of Structures 1 Fee Required $100.00 Fee Paid Owner's Signature ~~ ~ Date Inspector's Signature J~,,¢' Date CITY OF OSHKOSH STANDARD CONDITIONS OF' APPROVAL Project Address ~'7~ ~>~3~9L~~ c/~X?- a~Permit # Please read the following informatiOn and sign at the bott°m to ackn°Wledge that you have read and agree to comply with these conditions. All habitable rooms must be provided With 8% light and'3.5% ;¢entilation.'' Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03, Garage spaces shall be'separ~ited ~om th~'~dx~'6iliii~~ ~i~iii'~/5i?3~6"~31-ifi~'iE~"~'i:i¢'8. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an'independent testing agency as having a minimum fire-resistive rating of 20 minutes. All drywall jOintS are required' to be taped/sealed unless the joints are 'fitted s° that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood Or drywall with the joints staggered. All penetrations in exterior walli~'~6~Tl~b~6'/fl~d'~iS~i~Si:Td"[i~'~'iii~s-~i~{ii3~'ih~'~[6h~-'~{'~ includes holes in the top and bottom plates, gaps around heating dUcts, and hOles in the return air spaces. Smoke detectors are required on every floor and Wi/bibS'6' 6f'~l' detectors are required to be hardwired and interconnected. o Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. 0 All overframing must be designed by the truss manufacturer, according to standards Set by the trUss plate institute, or strUctural calculations must be provided prior to the rough building inspection. 7. TrUss plans must be submitted and approved prior to framing the roof. Truss plans including the tress layout must be provided on site at th~i~6iigh buildifig ........ . inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point 10ad~ 0ii them. Calculations must be provided for all cantilegered floors with point 10adS~'~' F10dr tresses and TJI's muSt be designed for the cantilevered areas. 10. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintained until the lawn is established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals must be roughed in prior to requeSting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re-inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. public works office, 3rd floor. / / All site grading must be done in accordance with the approved drainage plan on file in the 0 I"-- ,£8'00I / / / / /