HomeMy WebLinkAbout0098539-BuildingOSHKOSH
ON THE WATER
Job Address
Designer
Category
Type
3750 PURPLE CREST CT
110 - New Single Family
CITY OF OSHKOSH No 0098539
BUILDING PERMIT -APPLICATION AND RECORD
Owner DEWEY HOMES Create Date 11/06/2002
Contractor DEWEY HOMES INC
· Building O Sign O Canopy O Fence O Raze
Plan D1-166-1002R
Zoning R-2 Class of Const: 8
Unfinished/Basement 1166 Sq. Ft. Rooms 6
Finished/Living 1166 Sq. Ft. Bedrooms 3
Garage 784 Sq. Ft. Baths 1
Foundation · Poured Concrete O Floating Slab (~ Pier
O Concrete Block O Post O Treated Wood
Occupancy Permit Required Flood Plain No
Park Dedication Required # Dwelling Units 1
Height 21 Ft.
Stories Quad-level
~Other
Size Irrg
[] Projection
Canopies
Signs
Height Permit Not Required
# StrUctures 1
Use/Nature NSFPJ New single family quad level, 3 car attached garage, 12' x 12' Patio. Driveway will be 20' wide at the front property line.
of Work .
HVAC Contractor
Electric Contractor
Fees: Valuation
Issued By: ~X(~
AMERICAN HEATING & A C CO
CUMINGS ELECTRIC
Plumbing Contractor P&S PLUMBING
$88,500.00 Plan Approval $75.00 Permit Fee Paid
[] Permit Voided
$347.00 Park Dedication $100.00
Date 11/11/2002 Final/O.P. 00/00/0000
In the performance of this w~oj;k I agree to perform.,,,ett'"work pursuant to rules governing the described construction.
Agent/Owner
Address 3876 PURPLE_(~,,RE'ST DR OSHKOSH WI 54901 - 8212 Telephone Number
920-231-3389
OSHKOSH
ON THE WATER
GRADE STAKE FORM
Name DEWEY HOMES Address
Lot 40 Block
Subdivision Meadow North Zone
Street Number Lot Dimensions
3750 PURPLE CREST CT
Grade Stake Number 6851
Create Date 11/06/2002
L_J Sidewalk Existing
Ward
Building Grade Elevation Stakes Set At Site 11/07/2002 Set By D.W.G. SIDEWALK NORTH PL
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation
has commenced. ~
V~isconsin Department of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
[] Constr
)wner's Name
DEWEY HOMES
Contractor: ~J Con[~ Elec'~ HVAC ~J Plbg Lic/Cert #
DEWEY HOMES lNG 250178
Contractor: L_J Con ~J ElecL_~ HVACLJ Plbg Lic/Cert #
CUMINGS ELECTRIC 170792
Contractor: I I Con ~_J ElecL~j HVAC [] Plbg Lic/Cert #
AMERICAN HEATING & A C CO 6356
Contractor:L._j Con [] Elec[~] HVACI~I Plbg Lic/Cert#
P&S PLUMBING
Lot Area Sq. ft.II
WISCONSIN UNIFORM Application No.
BUILDING PERMIT 0098539
APPLICATION Parce No.
[] HVAC [] Elec [] Plbg [] Erosion [] Other:
Mailing Address
3876 PURPLE CREST DR Oshkosh
ITelephone
No.
WI 54901- 00001Telephone
No.
WI 54901- 82121920-231-3389
ITelephone No.
WI 54957 -749 1231-5946
Mailing Address
3876 PURPLE CREST DR
OSHKOSH
Mailing Address
PO BOX749 1414 COUNTY RD JJ NEENAH
Mailing Address
1129 MICHIGAN AVE OSHKOSH
WI54902
Telephone No.
-6437 (920)235-8090
Telephone No.
734-3912
Mailing Address
PO BOX 2153 APPLETON WI 54913 - 0
1/4, 1/4,Section ,T · N,R E(or)W
Building Address Subdivision Name Lot No. Block No.
3750 PURPLE CREST CT Meadow North 40
Permit No. Front Rear Left Right
New [] Repair Single Family Entrance Panel Forced Air Furnace Fuel
[] Alteration [] Raze Two Family Size: __ Radiant Baseboard or Panel
Garage Service: [] Heat Pump Space Htg
[] Addition [] Move Other (print): [] Overhead [] Boiler Water Htg
[] Other: [] Underground Central Air Conditioning -- ~g unit will have 3 kilowatt or
Other more installed electric space heating equip.
[] Site Constructed Concrete Infiltration control option is: [] Full sealing
Unfinished [] Manufactured [] Masonry Sewer of joints. [] Blower door test. [] Exterior
Basement 1168 Sq. ft. [] Treated Wood [] Municipal air infiltration barrier.
Living Area 1168 Sq. ft. l-Story [] Other i[~] Septic
Garage 784 Sq. ft. [] 2-Story Permit No. Envelope 22155 BTU/HR
[] Other [] Seasonal Infiltration 14296 BTU/HR
Quad-level [] Permanent [] Municipal Utility
[] Plus Basement [] Other [] Private On-Site Well $100,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
AI31~,~V,~/~nl~lnlTl~l~l.~'''~his permit is~5~rsuant to the following conditions. Failure to comply may result in suspension or
..................... revocation of-thl~ permit or other penalty
SEE "STANDARD CONDITIONS OF APPROVAL" SHEET
[]Town
[] Village [] City [] County ~ State of: Municipality Number of Dwelling LoCation:
CityOf Oshkosh 7 0 - 2 6 6
Plan Review $75.00 Construction
HVAC Name JOHN ZARATE
Inspection Electrical
Wis. Permit Seal $30.00 [] Plumbing Date 11/6/02
Other [] Erosion
Total $105.00 275830 Cert. No. 70330
SBD-5823 (R. 07~92)
OSHKOSH
ON THE WATER
Job Address
Name
Address
Subdivision
PARKLAND DEDICATION FEE COLLECTION RECORD
3750 PURPLE CREST CT
DEWEY HOMES
3876 PURPLE CREST DR
Meadow North
Building Permit Number 0098539
Number of Dwelling Units 1
Fee Required $100.00
Owner's Signatu~
Inspector's Signature
Date 11/11/2002
Oshkosh WI 54901
Lot 40
Number of Structures
Fee Paid
Date
Date
CITY OF OSHKOSH
STANDARD CONDITIONS'OFAPPROV~L
Project Address ~-7S0 ~ur?)~- (~¢~ [, C~ Permit #
Please read the following information and sign at the bottom tO acknowledge thhf ~/~U'haVe read
and agree to comply with these conditions.
All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire-reSistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or
drywall with the joints staggered.
All penetrations in exterior walls must be Sealed prior to the insulation inspeCtiOn, This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish Of the house.
All overframing must be designed by the tress manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10.
11.
12.
13.
14.
16.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintained until the lawn is established.
All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at' the'end'6f ~aCh w0ikda~i~ l~ep~air ~ ........
siltation or erosion damage to adjoining surfaces afid'drhifi~i~e~ti~;si~ii~iiing from land
development or disturbing activities.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
All mechanicals must be roughed in prior to requesting the rough bUilding ihspectiOn. If
on the inspection the mechanicals are not roughed in, the' inspection-Will fail and a $i
re-inspection fee will be charged.
Attached is a copy o£the final inspection checklist. At the final inspectiOn all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only-allowed tO be placed'in the dentei
of the garage floor and a minimum of a 3' pathway must be proVided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrige~rfi~0f~ washei/,' ~ddry~r~'n0~'~6'b'e"§et ih
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of tile
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.
O'Z8