Loading...
HomeMy WebLinkAbout0098539-BuildingOSHKOSH ON THE WATER Job Address Designer Category Type 3750 PURPLE CREST CT 110 - New Single Family CITY OF OSHKOSH No 0098539 BUILDING PERMIT -APPLICATION AND RECORD Owner DEWEY HOMES Create Date 11/06/2002 Contractor DEWEY HOMES INC · Building O Sign O Canopy O Fence O Raze Plan D1-166-1002R Zoning R-2 Class of Const: 8 Unfinished/Basement 1166 Sq. Ft. Rooms 6 Finished/Living 1166 Sq. Ft. Bedrooms 3 Garage 784 Sq. Ft. Baths 1 Foundation · Poured Concrete O Floating Slab (~ Pier O Concrete Block O Post O Treated Wood Occupancy Permit Required Flood Plain No Park Dedication Required # Dwelling Units 1 Height 21 Ft. Stories Quad-level ~Other Size Irrg [] Projection Canopies Signs Height Permit Not Required # StrUctures 1 Use/Nature NSFPJ New single family quad level, 3 car attached garage, 12' x 12' Patio. Driveway will be 20' wide at the front property line. of Work . HVAC Contractor Electric Contractor Fees: Valuation Issued By: ~X(~ AMERICAN HEATING & A C CO CUMINGS ELECTRIC Plumbing Contractor P&S PLUMBING $88,500.00 Plan Approval $75.00 Permit Fee Paid [] Permit Voided $347.00 Park Dedication $100.00 Date 11/11/2002 Final/O.P. 00/00/0000 In the performance of this w~oj;k I agree to perform.,,,ett'"work pursuant to rules governing the described construction. Agent/Owner Address 3876 PURPLE_(~,,RE'ST DR OSHKOSH WI 54901 - 8212 Telephone Number 920-231-3389 OSHKOSH ON THE WATER GRADE STAKE FORM Name DEWEY HOMES Address Lot 40 Block Subdivision Meadow North Zone Street Number Lot Dimensions 3750 PURPLE CREST CT Grade Stake Number 6851 Create Date 11/06/2002 L_J Sidewalk Existing Ward Building Grade Elevation Stakes Set At Site 11/07/2002 Set By D.W.G. SIDEWALK NORTH PL Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. ~ V~isconsin Department of Industry, Labor and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 [] Constr )wner's Name DEWEY HOMES Contractor: ~J Con[~ Elec'~ HVAC ~J Plbg Lic/Cert # DEWEY HOMES lNG 250178 Contractor: L_J Con ~J ElecL_~ HVACLJ Plbg Lic/Cert # CUMINGS ELECTRIC 170792 Contractor: I I Con ~_J ElecL~j HVAC [] Plbg Lic/Cert # AMERICAN HEATING & A C CO 6356 Contractor:L._j Con [] Elec[~] HVACI~I Plbg Lic/Cert# P&S PLUMBING Lot Area Sq. ft.II WISCONSIN UNIFORM Application No. BUILDING PERMIT 0098539 APPLICATION Parce No. [] HVAC [] Elec [] Plbg [] Erosion [] Other: Mailing Address 3876 PURPLE CREST DR Oshkosh ITelephone No. WI 54901- 00001Telephone No. WI 54901- 82121920-231-3389 ITelephone No. WI 54957 -749 1231-5946 Mailing Address 3876 PURPLE CREST DR OSHKOSH Mailing Address PO BOX749 1414 COUNTY RD JJ NEENAH Mailing Address 1129 MICHIGAN AVE OSHKOSH WI54902 Telephone No. -6437 (920)235-8090 Telephone No. 734-3912 Mailing Address PO BOX 2153 APPLETON WI 54913 - 0 1/4, 1/4,Section ,T · N,R E(or)W Building Address Subdivision Name Lot No. Block No. 3750 PURPLE CREST CT Meadow North 40 Permit No. Front Rear Left Right New [] Repair Single Family Entrance Panel Forced Air Furnace Fuel [] Alteration [] Raze Two Family Size: __ Radiant Baseboard or Panel Garage Service: [] Heat Pump Space Htg [] Addition [] Move Other (print): [] Overhead [] Boiler Water Htg [] Other: [] Underground Central Air Conditioning -- ~g unit will have 3 kilowatt or Other more installed electric space heating equip. [] Site Constructed Concrete Infiltration control option is: [] Full sealing Unfinished [] Manufactured [] Masonry Sewer of joints. [] Blower door test. [] Exterior Basement 1168 Sq. ft. [] Treated Wood [] Municipal air infiltration barrier. Living Area 1168 Sq. ft. l-Story [] Other i[~] Septic Garage 784 Sq. ft. [] 2-Story Permit No. Envelope 22155 BTU/HR [] Other [] Seasonal Infiltration 14296 BTU/HR Quad-level [] Permanent [] Municipal Utility [] Plus Basement [] Other [] Private On-Site Well $100,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of AI31~,~V,~/~nl~lnlTl~l~l.~'''~his permit is~5~rsuant to the following conditions. Failure to comply may result in suspension or ..................... revocation of-thl~ permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET []Town [] Village [] City [] County ~ State of: Municipality Number of Dwelling LoCation: CityOf Oshkosh 7 0 - 2 6 6 Plan Review $75.00 Construction HVAC Name JOHN ZARATE Inspection Electrical Wis. Permit Seal $30.00 [] Plumbing Date 11/6/02 Other [] Erosion Total $105.00 275830 Cert. No. 70330 SBD-5823 (R. 07~92) OSHKOSH ON THE WATER Job Address Name Address Subdivision PARKLAND DEDICATION FEE COLLECTION RECORD 3750 PURPLE CREST CT DEWEY HOMES 3876 PURPLE CREST DR Meadow North Building Permit Number 0098539 Number of Dwelling Units 1 Fee Required $100.00 Owner's Signatu~ Inspector's Signature Date 11/11/2002 Oshkosh WI 54901 Lot 40 Number of Structures Fee Paid Date Date CITY OF OSHKOSH STANDARD CONDITIONS'OFAPPROV~L Project Address ~-7S0 ~ur?)~- (~¢~ [, C~ Permit # Please read the following information and sign at the bottom tO acknowledge thhf ~/~U'haVe read and agree to comply with these conditions. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire-reSistive rating of 20 minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or drywall with the joints staggered. All penetrations in exterior walls must be Sealed prior to the insulation inspeCtiOn, This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish Of the house. All overframing must be designed by the tress manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. Calculations must be provided for all cantilevered floors with point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. 11. 12. 13. 14. 16. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintained until the lawn is established. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at' the'end'6f ~aCh w0ikda~i~ l~ep~air ~ ........ siltation or erosion damage to adjoining surfaces afid'drhifi~i~e~ti~;si~ii~iiing from land development or disturbing activities. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. All mechanicals must be roughed in prior to requesting the rough bUilding ihspectiOn. If on the inspection the mechanicals are not roughed in, the' inspection-Will fail and a $i re-inspection fee will be charged. Attached is a copy o£the final inspection checklist. At the final inspectiOn all items on this list must be completed to avoid the $100 re-inspection fee per inspection. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only-allowed tO be placed'in the dentei of the garage floor and a minimum of a 3' pathway must be proVided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrige~rfi~0f~ washei/,' ~ddry~r~'n0~'~6'b'e"§et ih place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of tile final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor. O'Z8 8