HomeMy WebLinkAbout2002-Letter (plumbing plan review - cross connection control) 4/5/02 � . - Safety and Buildings � � 2331 SAN LUIS PL STE 150 � GREEN BAY WI 54304 ` TDD#: (608)264-8777 isconsin ��ommercestate wi us/sb wvnv.wisconsin.gov Department of-Commerce Scott McCallum,Govemor - Philip Edw.Albert,Secretary ApriL 05, 2002 CUST ID A0.?330S3 ATTN: Plmnbinglns'pector JEFFREY D OGDEN MUNICIPAL CLERK OGDEN PLUMBING CITY OF OSHKOSH 1010 STROHMEYER DR PO BOX I li0 NEENAH WI 549�7 OSHKOSH WI Sd902-1130 CO�DITIOVAL APPROVAL PL.a\APPROVAL EXPIRES: 0a/0S/?004 Identification\umbers Transuction iD No. 72C677 SITE: � Site ID No. 641759 � Ge Power System Plan[ Please refer to both identification numbers, 3300 Medalis[Dr I aboce, m all correspondence with the.a_encv. Ciry of Oshkosh, �4901 Winnebago Counry FOR: Description: 2" Watts 909QT Rp Valve Servin2 Test S[ation Object Type: Cross Conneetion Cootiol Device Regulated Objeet ID No.: 83d713 Device Type: Reduced Pressure Preventer; Location On Property: Hydroflo Test Station; �lanufacturer: Watts; �IodeL 909QT; Plan Type: Addition; 2" Valve Size The submittal described above has been reviewed for conformance widt applicable Wisconsin Adnunistratice Codes and Wisconsin S[atures. The submittal has been CO\D[TIONALLY APPROVED. The o�vnec as detined in chapter 10 L0l(10), Wisconsin Stanues. is responsibla Cor eompliance �vidi all code requiremcn[s. The following conditions shall be met during construction or installation und prior to occupancy or use: Key Item(s) #1. Comm 82.40(3)(d)3. The installation of each RP,RP detector, PVB and SVB shall display a departmen[ assiened identification number. #2. Insmll assembly pec Comrr�3?.4l (�)(t). Also Address . - It is the responsibility of[he o���ner to make sure the device is tes[ed and tha[ the [est report forms (SBD-9927) is sen[ to tlie Saf'ety and Buildings Division upon comple[ion o(Ihe [esL A deparhnent-lis[ed BucWlow Prevention Device Tester shall perCorm[he [est. A list ot testers is available from[he department upon request. • -A TEST SH?,LL BE CO�DUCTED ON E?,CH RP,PVB,OR SVB PRIOR TO IT BEING PtiT INTO SERVICE,AND A bIINIY[UM OF ONCE A YEAR THEREAFTER. • -The backllow preventer shall be installed so that the relief valve outle[is protected by an approved air- gap. The drain from the relief valve must discharge to ei[her a floor drain or an approced recep[or.\o part of[he backtlo�v preven[er may be submerged under any circumstance. . -RP,PVB,or SVB's shall no[ be b��-passed. Escept for repair, the}�shall not be made inoperatire or removed without departmental appro��al. A cop}'ot rhe approved plans. speciHcatiuns �nd [his lerter shall be on-site duri�tu co�sm�ction mi� open to inspzctiun by aud�orized represen[aei��es o[[hz Department, ���hich ma}� includz locsl inspecturs. .-\Il pemlies JEFFREY D OGDGN Page 2 4i5/02 required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. � In�ranting this approva]the Division of Safety&Buildin�s resen�es the right ro require chanees or additions sl�ould conditions arise making them necessary for code compliance.As per state stats 10112(2),nothing in this revie�v shall relieve the designer of the responsibility for designing a safe building, shucture, or component. Inquiries conceming this correspondence may be made to me at the telephone number listed below,or at the address on this letterhead. Sincerely, �� Fee Required S 12�.00 �_ Fee Received� 1?�.00 � 1 �/� �' Balance Due $ 0.00 / �Vesle�Cd�be I Plumbin�Plan Reviewer,Integiated Services WiSMART code: 76�7 '� (920)49?S613 , M-R 7:00- 16:30, F 7:00- 11:00 wembe�u,c ommeic e.state.wi.us cr. I D Oeden Plumbing&Hentin�Inc James E Zickert, Plumbing Consuliant, (920) 943-T36 A-C Compressor i Ge