Loading...
HomeMy WebLinkAbout2002-Letter (plumbing plan review - cross connection control) 6/4/02 a � Safety and Buildings �I , � 4003 N KINNEY COULEE RD I, LA CROSSE WI 54601-1831 � � TDD#:(608)264-8777 � iscons�n www commerce state wi us/sb www.wisconsin.gov Department of Commerce Scott MCCallum,Governor Philip Edw.Albert,Secretary June 04, 2002 CUST ID No233083 A7TN: Plumbinglnspector JEFFREY D OGDEN MUNICIPAL CLERK OGDEN PLUMBING CITY OF OSHKOSH i010 STROHMEYER DR PO BOX I130 �'EENAH Wf 54957 OSHKOSH WI 54903-I130 CONDITIONAL APPROVAL PLAN .4PPROVAL EXPIRES: 06/0�/2001 [dentification Numbers Transaction [D No. 753978 SITE: Site [D No. 641759 A-C Compressure/Ge Power System Plant Please refer[o both iden[ifica[ion numbers, 3300 Medalist Dr above, in all corres ondence with [he a�enc �. Ciry of Oshkosh, 54901 W innebago County FOR: Description: Serving Porming Press Object Type: Cross Connzction Control Device Regulated Object ID No.: 853625 Dzvice��ype: Reduced Pressure Preventer, Location On Property: �1achine S. of Mfg. Oftice; Manufacturec Wans: Model: 909QT; Plan T}pe: Additiun; l-I/4" Valve Size The submittal described above has been revia���ed for conformance with applicable Wisconsin Administrative Codes and Wisconsin 5[a[utes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Stamtes, is responsible for compliance with all code requirements. The lollowing conditions shall be met during consvuction or ins[allation and prior to occupancy or use: Ke�� Item(s) • Comm ft?.40(3)(d)3. The installation of each RP. RP derector, PVB and SVB shall display a depanment assigned identifica[ion number. • -The backflow preventer shall be installed so that the relief valve oude[ is protec[ed by an approved air-gap. The drain from the relief valve must discharge to either a Floor drain or an approved receptor. No part of[he backflow preventer may be submerged under any circums[ance. • - RP, PVB, or SVB's shall no[ be bq-passed. Escept for repair,they shall no[be made inoperative or removed withuut departmental approval. • Comm 8?.d I(5)(e). The floor drain or recepror ro receive Ihe discharge of the reduced pressure principle backFlow preven[er relief vah�e shall be sized to handle the an[icipated discharge. • - It is the responsfbiliry of Ihe owner ro make sure the device is tes[ed and ihat Ihe test report fomu(SBD-9927) is sent to the Safety and Buildings Division upon completion of the test. A department-listed Backflow Prevention Device Tester shall perform the rest A list of testers is available from the depanment upon request. • -A TEST SHALL I3E CONDUCTED ON EACH RP.PVB, OR SVB PRIOR TO IT BEING PUT MTO SERVICE, AND A MWIMUM OF ONCE A YEAR THEREAFT6R. A copy of the approved plans, specitications and this letter shall be omsite during construction and open to inspection by authorized representatives of d�e Depanment, which may include local inspectors. AII permi[s �cyuir��J b� ihe statt or the local nuinicipality shull be obtained prior to commencement oC cons�rucuun'instal la[ion/operation. JEFFREY D OGDEN Page 2 6/4/02 In gran[ing this approval Ihe Division of Safety& Buildings reserves the right to require chan�es or addi[ions should conditions arise making them necessaq� for code compliance. As per stare stats 10 L 12(2), nothing in [his review shall relieve[he designer of ihe responsibility for desi�ning a saEe building, siruc[ure,or component. Inquiries concerning this correspondence may be made to me at the telephone number lis[ed below,or a[ihe address on this Ie[terhead. Sincerely, Fee Required$ 125.00 Fee Received$ 125.00 ��. ,,,;,��j � ���� Balance Due � 0.00 Herman J Delfosse Plumbing Plan Reviewer? , Integrated Services bViSMART code� 7657 (608)789-5�35 . Mon -Thur 6:45 -4:30 Fri 6:45-10:4� hdelfosse r commerecs�ate.�vi.us cc: James E Zickert. Plumbing Consultant,(920)948-7336 A-C Compressor/Ge