Loading...
HomeMy WebLinkAbout0110460-Building (dining room addition)OSHKOSH ON THE WATER · lob Address 427 HOBBS AVE Designer Category Type Zoning CITY OF OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD Owner JAMES E/SHARON ALLISON TRUST Contractor DAN V BINDER CONSTRUCTION 111 - Single Family Addition · Building C) sign Unfinished/Basement 0 Sq. Ft. Finished/Living 0 Sq. Ft. Garage 0 Sq. Ft. Foundation · Poured Concrete (~ Floating Slab (~ Concrete Block (~ Post Occupancy Permit Required Park Dedication Canopy (~ Fence (~ Raze No 110460 Create Date 09/13/2004 Plan Class of Const: Rooms 0 Height 0 Ft. Bedrooms 0 Stories Baths 0 (~ Pier C) Other ~) Treated Wood Flood Plain Height Permit # Dwelling Units 0 # Structures 0 Size ~_P?iecjio.~ Canopies 0 Signs 0 Use/Nature FPJ Constructing a 6'x11' rear entry/dining room addition. All construction shall comply with state and local building code requirements. of Work HVAC Contractor Electric Contractor Fees: Valuatio~ Issued By: ~ Plumbing Contractor SLIM'S ELECTRIC, INC. $8,000.00 Plan Approval $0.00 Permit Fee Paid [] Permit Voided~ $62.00 Park Dedication $0.00 Date 09/13/2004 Final/O.P. 00/00/0000 Parcelld # 1209380000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secu(~ any necessary/?l~3//~vals b.~/9/starting such activity. Signature ~ I AgentYOwner Address 1224 W SOUTH PARK AVE OSHKOSH WI 54902 - 0000 Telephone Number 231-2114 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. ZONING/LAND USE COMPLIANCE CHECKLIST JOB LOCATION: L~'~ -~,~ PROPERTY OWN~NTRACT~ ~ k-~;S~z~-- ~ CONSTRUCTION DATA: [] New Construction ~ddition TYPE OF CONSTRUCTION: (i.e. fence, pool, parking lot, sign, etc.) ZONING: "~' [, [] Alteration COMPLIANCE CHECKLIST DEFICIENT [] Use Lot Width [] Lot Area Lot Area Per Family [] Flood Plain [] Front Yard [] Front Yard Side Street COMMENTS: DEFICIENT [] Rear Yard [] Side Yards [] Building Area [] Parking Standards [] Off-Street Loading Standards [] Vision Clearance [] Transitional Yard Standards DEFICIENT [] Landscape Standards [] Height [] Conditions of Approval [] Compliance with P.C. or BZA Conditions of Approval [] Signage Standards [] Mechanical Equip. Screening [] Parking Lot Lighting REVIEW AUTHORITY As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approve all plans, except the following: (1) Alterations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc., when the use is conforming and when no change is proposed. DAPPROVED Plan Commission Action Required [] DENIED Variance(s) Required REVIEWED BY: ~_~ 2003 5 100.0' L 65.0' ,~ , 73.5' DISCLAIMER Site Plan (~ N a snrvey ..d . ,, .o, ,.,.ded to he .,ed a, o.e. 427 Hobbs Ave. This drawing is a compilation of records, datax.~ l.l.~v u I [J L ~ and informatlon located in various city, county City of Oshkosh Wisconsin the area shown and it is to be used for reference t'~o1Tlmun;~-~ r r~eve'o"men+ OJ'H KO./'H city of Oshkosh. 1" = 20' Created by- VR 8-17-04 . WIScheck COMPLIANCE REPORT I I Wisconsin Uniform Dwelling Code � Permit # � WIScheck Software Version 1.0 Release 3 I I � � iChecked by/Date i COUNTY: Winnebago HEATING TYPE: Non-Electric DATE: 9-8-2004 DATE OF PLANS: SEPT. 8, 2004 PROJECT INFORMATION: 6 X 11 ADDITION 427 HOBBS STREET OSHKOSH, WI COMPANY INFORMATION: BINDER CONSTRUCTION UDC COMPLIANCE: Passes Code-Allowed UA = 35 Your Home = 30 14.3� Better Than Code Area or Cavity Cont. Glazing/Door Perimeter R-Value R-Value U-Value UA ------------------------------------------------------------------------------- CEILINGS 66 38.0 0.0 2 WALLS: Wood Frame, 16" O.C. 183 19.0 0.0 11 GLAZING: Windows or poors, Above Grade 9 0.320 3 DOORS 20 0.140 3 CRAWL: Concrete 48" ht/ 42" bg/ 48" insul. 92 5.0 11 HVAC EQUIPMENT: Furnace, 92.0 AFUE ------------------------------------------------------------------------------- COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet t equirements o t Wi Uniform Dwelling Code. Builder/Designer Date � O . TITLE: HEATING EQUIPMENT SIZING SUMMARY General Information: Outdoor Design Temperature: -15 deg Conditioned Floor Area: 66 ft2 Average Ceiling Height: 8.0 ft Infiltration Rate: 0.50 Normalized ACH Equipment Oversizing Factor: 15.0 � ; Loads Summary: Conductive Losses: 2515 Btu/hr Infiltration Losses: 404 Btu/hr Oversizing Factor Losses: 438 Btu/hr ; Total Building Heating Load: 3357 Btu/hr � . TITLE: WIScheck INSPECTION CHECKLIST Wisconsin Uniform Dwelling Code WIScheck Software Version 1.0 Release 3 { DATE: 9-8-2004 Bldg. � � Dept- � Use I � � CEILINGS: [ l � 1. R-38 � Comments/Location � � WALLS: [ ] � 1. Wood Frame, 16" O.C. , R-19 � Comments/Location � I WINDOWS AND GLASS DOORS: [ ] � 1. U-value: 0.32 � Windows must be labeled and rated in accordance with NFRC or � must use default values from CONIlK Table 22.05-1. � For windows without labeled U-values, describe features: � # Panes Frame Type Thermal Break? [ ] Yes [ ] No � Comments/Location � � DOORS: L ] � 1. U-value: 0.14 � Doors must be labeled and rated in accordance with NFRC or � must use default values from CONII�I Table 22.05-2. � Comments/Location � � CRAWL SPACE WALLS: ' [ l � l. Concrete 48" ht/ 42" bg/ 48" insul. , R-5 � Comments/Location � Applies to walls of unventilated crawl spaces. � � HVAC EQUIPMENT: [ l � 1. Furnace, 92.0 AFUE or higher � Make and Model Number � � AIR LEAKAGE: [ l � Joints, penetrations, and all other such openings in the building ienvelope that are sources of air leakage must be sealed. � Recessed lights must be type IC rated and installed with no � penetrations or installed inside an appropriate air-tight assembly � (CONIl�I 2 2.3 2) . � � VENTILATION: [ ] � Mechanical ventilation systems must be balanced. Intake air ducts imust be sized to provide a minimum of 40� of the total air that would be exhausted with all exhaust ventilation in the dwelling iacting simultaneously (CONIM 23 .02 (3) ) . � VAPOR RETARDER: . [ l � Required on the warm-in-winter side of all non-vented framed � ceilings, walls, and floors. ( � MATERIALS IDENTIFICATION: . TITLE: [ ] iMaterials and equipment must be identified so that compliance can ;' be determined. Manufacturer manuals for all installed heating # � and cooling equipment and service water heating equipment must be � provided. Insulation R-values, glazing U-values, and heating � equipment efficiency must be clearly marked on the building plans � or specifications. � � DUCT INSULATION: [ ] i Ducts in unconditioned spaces must be insulated to a minimum of R-5 (COMM 22.17) . � I TEMPERATURE CONTROLS: [ ] � Thermostats are required for each separate HVAC system. A manual or � automatic means to partially restrict or shut off the heating and/or � cooling input to each zone or floor shall be provided (COMM 22 .15) . � I HUMIDITY CONTROL: [ ] i A humidistat is required when humidifying or dehumidifying (COMM 22.16) . I PIPE INSULATION: [ ] � All heating pipes in unheated spaces and all cooling pipes in � uncooled spaces must be insulated with a material providing � a minimum thermal resistivity of R-4 (CONIl�I 22.19) . ----NOTES TO FIELD (Building Department Use Only) -------------------------