PLAN COMMISSION STAFF REPORT DECEMBER 2, 2025
ITEM 9: Architectural Building Plan Review for New Wastewater Treatment Buildings at
233 North Campbell Road
Applicant: Stephen Matthias
Owner: City of Oshkosh
Action Requested: The applicant is requesting an architectural building plan review for a new
tertiary filtration building and UV disinfectant building.
Applicable Ordinance: State Statute 62.23(5) requires the Plan Commission review the “location
and architectural design of any public building”.
Property Location and Background Information: The subject site is an 11.42-acre property with
frontage on North Campbell Road, Dempsey Trail, Knapp Street, and Campbell Creek. The site is
used as the City’s wastewater treatment plant and includes several structures and associated
paved areas. The surrounding area consists of University athletic fields and vacant land to the
north, institutional and multi-family residential uses to the east, and a mixture of industrial and
commercial uses to the south and west. The 2040 Comprehensive Land Use Plan recommends
Community Facility use for the subject site.
Existing Land Use Zoning
Waste Water Treatment Plan I
Recognized Neighborhood Organizations
Marina District
Adjacent Land Use and Zoning
Existing Uses Zoning
North University & Vacant I & I-PD
South Commercial & Industrial I & UI
East Institutional & multi-family residential I & RMU
West Commercial & Industrial UI, UI-PD & MR-12
The City has identified the need for two additional buildings on the existing waste water
treatment site to aid in impending treatment limits of the plant and upgrade existing treatment
operations. The first proposed building is on the northwest portion of the site adjacent to
Campbell creek and will contain new tertiary filtration units and other ancillary equipment. The
second proposed building will contain new UV disinfection treatment equipment. This building
will be constructed over an existing tank (reusing the existing foundation).
Page 1
Item 9 – 233 N Campbell Rd. – Arch. Building Review
Architectural building plan review is required for the two new buildings. According to the
applicant, the new building walls will consist of tilt-up precast panels with a brick form liner
finish on the exterior. The existing buildings have block walls with brick exterior. The brick form
liner pattern of the proposed precast panels is intended to match the face brick on the existing
buildings and will be stained to match the color of the existing buildings. There will be a white
band around the top of the walls similar to some of the other buildings at the wastewater
treatment site. The applicant has noted that on past projects this approach has produced building
facades that look very similar to adjacent buildings with genuine brick and block walls.
Page 2
Item 9 – 233 N Campbell Rd. – Arch. Building Review
Staff has determined that the proposed building designs will not have a negative impact on the
surrounding area as the structures will be harmonious with the intended character of the large-
scale public utility site. Although the site’s existing buildings have a brick exterior, the proposed
pre-cast panels with brick form liner will provide a consistent appearance with other existing
buildings on the site. The City’s zoning ordinance does not have design standard requirements
for institutional buildings.
Tertiary Filtration Building Elevations
Page 3
Item 9 – 233 N Campbell Rd. – Arch. Building Review
UV Building Elevations
Recommendation: Staff recommends approval of the architectural design of the proposed tertiary
filtration building and UV disinfectant building.
Page 4
Page 5
Page 6
Supplemental Information to Application
City of Oshkosh General Application (Oct 20, 2025)
Revised 11/3/2025
Narrative of the proposed request – Oshkosh WWTP Tertiary Filtration
and UV Disinfection
The City of Oshkosh (City) owns and operates a wastewater treatment plant (WWTP) which resides
on an existing 30.01-acre City-owned property at the intersection of N Campbell Creek Road and
Dempsey Trail. The treatment plant treats incoming wastewater and discharges treated effluent to
the Fox River and Campbell Creek. The City has identified the need for two additional buildings on
the existing WWTP site to aid in impending treatment limits of the plant and upgrade existing
treatment operations. The WWTP also is also upgrading their service entrance equipment and
replacing existing generators.
The first proposed building is planned for on the northwest portion of the site adjacent to Campbell
creek and will contain new tertiary filtration units and other ancillary equipment. The new building
will require routine chemical deliveries (once every 2-3 weeks) by semi-trucks that will enter the site
off of N Campbell Road. The new building will be joined to the existing north parking lot by a new
access road. The truck deliveries are expected to cause only a minimal increase in truck traffic, as
the WWTP already receives several chemical deliveries.
The second proposed building will contain new UV disinfection treatment equipment. This building
will be constructed over an existing tank (reusing the existing foundation), causing a minimal
impact to the existing landscape. The new equipment in this building will eliminate the need for the
WWTP to receive chlorine gas cylinders will reduce truck traffic to the site. Figure 1 and Figure 2
shows preliminary exterior renderings of the two new buildings with their relation to the existing site
features.
The new building walls will consist of tilt-up precast panels with a brick formliner finish on the
exterior. The brick pattern will match the face brick on the existing buildings and will get stained to
match the color of the existing buildings. There will be a white band around the top of the walls
similar to some of the other buildings at the WWTP site. On past projects, this approach has
produced building facades that look very similar to adjacent buildings with genuine brick and block
walls.
Both new buildings will include exterior HVAC equipment that is not expected to increase noise
levels above the required ordinance levels at the site. No other impacts to adjoining properties are
expected. There will be no change to the existing parking at the site. The site’s impervious surface
Page 7
ratio with the proposed improvements will increase to 35%, which is still below the allowable 60%
threshold.
The entrance service electrical equipment replacement will require the removal of two trees along
Demsey Trail. New trees will be planted in-kind on the north end of the plant. The new generator
equipment will require one additional wall louver on the front of the generator building (see
Figure 3), one additional HVAC intake hood on the roof, and an exterior generator fuel tank. The
intake hood on the roof will be similar in size to the other two existing units, which are not visible
from the road. No other impacts to adjoining properties are expected.
Figure 1 - Proposed WWTP Building Renderings Looking Approx. Northeast from Demsey Tr
New UV Disinfection
Building
New Tertiary Filtration Building
Existing Control Building
Existing Tanks
偡来‸
Figure 2 – Tertiary Filtration Building Rendering, Approximately Looking North
Figure 3 – Existing Generator Building Looking North Showing Proposed Wall Louver Location
Proposed wall louver on
Existing Generator Building
New Tertiary Filtration Building New Access Road
Page 9
X
X
X
XX
X
XX
XXXXXXXXXXX
X
X
X
X
X
X
X
X X X X X X X X X X X
X
X
X
X
HHHH
100-YR
100-YR
100
-
Y
R
100-Y
R
100-YR 100-YR 100-YR 100-YR
100-YR
100-YR
10
0
-
Y
R
100-YR
100-YR
100-YR
100-YR 100-YR
100-
Y
R
100-YR
100-YR
DEMPSEY TRAIL
N
C
A
M
P
B
E
L
L
R
O
A
D
CAMPBELL CREEK
UP
UP
0 50'
Drawing No.
Designed By
Checked By
Filename
Approved By
Project No.
Drawn By
Re
v
i
s
i
o
n
Nu
m
b
e
r
Re
v
i
s
i
o
n
D
e
s
c
r
i
p
t
i
o
n
Dr
a
w
n
By
Da
t
e
Ch
e
c
k
e
d
By
Sheet No.
Project Date
QC
R
E
V
I
E
W
CI
T
Y
O
F
O
S
H
K
O
S
H
WA
S
T
E
W
A
T
E
R
T
R
E
A
T
M
E
N
T
P
L
A
N
T
TE
R
T
I
A
R
Y
T
R
E
A
T
M
E
N
T
AN
D
U
V
D
I
S
I
N
F
E
C
T
I
O
N
C
O
N
S
T
R
U
C
T
I
O
N
14556-T
SEP 2025
440
TERTIARY FILTRATION
BUILDING
FFE: 753.00
110
100
120
140
150
200
700
300
301303
302304
410 310
411
412
421
422
420
430
424
423
491
492
600
800
550
500
BUILDING LEGEND
100 - HEADWORKS BUILDING
110 - ADMINISTRATION BUILDING
120 - MAINTENANCE BUILDING
140 - DAFT BUILDING
150 - CHEMICAL BUILDING
200 - GRIT TANKS
300 - PRIMARY TREATMENT
310 - ELECTRICAL CONTROL BUILDING "A"
301-304 - PRIMARY CLARIFIERS NO. 1-4
410 - AERATION TANKS
411-412 - AERATION TANKS NO. 1-2
420 - SECONDARY TREATMENT
421-424 - SECONDARY CLARIFIERS NO. 1-4
430 - ELECTRICAL CONTROL BUILDING "B"
440 - TERTIARY FILTRATION BUILDING
490 - DISINFECTION FACILITY
491-492 - CHLORINE CONTACT TANKS NO. 1-2
500 - DIGESTER COMPLEX
550 - WASTE GAS BURNER
600 - SOLIDS BUILDING
700 - GENERATOR BUILDING
800 - TUNNEL
ORDINARY HIGH WATER MARK
100-YR FLOOD HAZARD
002-CR-1
002-CF-1
002-CP-1
002-CG-1
002-EP-1
002-CR-2
002-CF-2
002-CP-2
002-CG-2
002-EP-2
002-CR-3
002-CF-3
002-CP-3
002-CG-3
490
DISINFECTION
FACILITY
FFE: 754.65
GENERAL NOTES:
1.SEE GENERAL NOTES ON 999-G SERIES DRAWINGS FOR ADDITIONAL NOTES
AFFECTING WORK ON THIS DRAWING.
2.WORK DENOTED AS FUTURE IS TO BE PERFORMED BY ANOTHER
CONTRACTOR UNDER THE ELECTRICAL SERVICE AND GENERATORS
CONTRACT. CONSTRUCTION MAY COINCIDE WITH WORK UNDER THIS
CONTRACT.
FUTURE ELECTRICAL
SERVICE EQUIPMENT
SI
T
E
D
E
V
E
L
O
P
M
E
N
T
KE
Y
P
L
A
N
002-CK-1
8
NMS
NMS
BEG
SAM
002CK1.DWG
SEE 490 DRAWINGS
SEE 430 DRAWINGS
Page 10
THRU-WALL SCUPPER,TYP. SEE A781 OVERFLOW SCUPPER CONDUCTOR HEADAND DOWNSPOUT.
SEE A781
AIR TERMINAL, TYP
GALVANNEALEDHOLLOW METAL DOORAND FRAME W/INSULATED GLASS
CONCRETE SPLASH
BLOCK, TYP. SEE A932
24'
-
11/2"
1'-
10
1/2"
16'
-11/2"
1'
-
10
1/2"
PRECAST CONCRETEWALL PANEL (FINISH 2)PRECAST CONCRETEWALL PANEL (FINISH 1)GUARDRAIL
WALL MOUNTED LADDER PREFINISHED METALCOPING
INFILL PANEL
EXHAUST FANSEE H DRAWINGS
OVERHEAD COILINGDOOR, TYP. SEE A802
GALVANNEALED HOLLOWMETAL DOOR AND FRAME W/
INSULATED GLASS, TYP. SEE A825
Drawing No.
Designed By
Checked By
Approved By
Drawn By
Revision
Number
RevisionDescription
Drawn
By
Date
Checked
By
Sheet No.
Project No.
Project Date
Filename 14556_440.RVT
SAM
CLS
SDR
SDR
81
440-AS-7
14556-T
SEP 2025
ELEVATIONS
TERTIARY
FILTRATION
BUILDING
CITY
OF
OSHKOSH
WASTEWATER
TREATMENT
PLANT
TERTIARY
TREATMENT
AND
UV
DISINFECTION
CONSTRUCTION
GENERAL NOTES:
1.SEE GENERAL NOTES ON 999-G SERIES DRAWINGSFOR ADDITIONAL NOTES AFFECTING WORK ON THISDRAWING.
1'8'0
NORTH ELEVATION
1'8'0
SOUTH ELEVATION
QC
RE
V
I
E
W
TERTIARY FILTRATION
BUILDING ELEVATIONS
Page 11
AIR TERMINAL, TYP.
PRECAST CONCRETEWALL PANEL (FINISH 2)
PRECAST CONCRETEWALL PANEL (FINISH 1)
CONC FILL IN SEWETWELL, SLOPE1/4"/FT TOWARDSPUMPS. CONC FILL
THICKNESS AT LP=2"
WALL MOUNTED LADDER GUARDRAIL
INFILL PANEL OVERHEADCOILING DOOR
GALVANNEALED HOLLOWMETAL DOOR AND FRAMEW/ INSULATED GLASS,
TYP. SEE A825
Drawing No.
Designed By
Checked By
Approved By
Drawn By
Revision
Number
RevisionDescription
Drawn
By
Date
Checked
By
Sheet No.
Project No.
Project Date
Filename 14556_440.RVT
SAM
CLS
SDR
SDR
82
440-AS-8
14556-T
SEP 2025
ELEVATIONS
TERTIARY
FILTRATION
BUILDING
CITY
OF
OSHKOSH
WASTEWATER
TREATMENT
PLANT
TERTIARY
TREATMENT
AND
UV
DISINFECTION
CONSTRUCTION
GENERAL NOTES:
1.SEE GENERAL NOTES ON 999-G SERIES DRAWINGSFOR ADDITIONAL NOTES AFFECTING WORK ON THISDRAWING.
1'8'0
WEST ELEVATION
1'8'0
EAST ELEVATION
QC
RE
V
I
E
W
TERTIARY FILTRATION
BUILDING ELEVATIONS
Page 12
ROOFTOP UNIT
PRECAST CONCRETEWALL PANEL (FINISH 2)
PRECAST CONCRETEWALL PANEL (FINISH 1)
WALL MOUNTED LADDER
GUARDRAIL AIR TERMINAL
GALVANNEALED HOLLOWMETAL DOOR AND FRAMEW/ INSULATED GLASS,
TYP. SEE A825
OVERFLOW SCUPPER,TYP. SEEA785
THRU-WALL SCUPPER,
TYP. SEE A781
WALL MOUNTED LADDER
GUARDRAIL
CONDUCTOR HEADAND DOWNSPOUT.SEE A781CONCRETE SPLASHBLOCK. SEE
A932
Drawing No.
Designed By
Checked By
Approved By
Drawn By
Revision
Number
RevisionDescription
Drawn
By
Date
Checked
By
Sheet No.
QC
RE
V
I
E
W
Project No.
Project Date
Filename 14556_420.RVT
SAM
CLS
SDR
SDR
125
490-AS-7
14556-T
SEP 2025
ELEVATIONS
DISINFECTION
FACILITY
CITY
OF
OSHKOSH
WASTEWATER
TREATMENT
PLANT
TERTIARY
TREATMENT
AND
UV
DISINFECTION
CONSTRUCTION
GENERAL NOTES:
1.SEE GENERAL NOTES ON 999-G SERIES DRAWINGSFOR ADDITIONAL NOTES AFFECTING WORK ON THISDRAWING.
1'8'0
NORTH ELEVATION
1'8'0
SOUTH ELEVATION
1'8'0
EAST ELEVATION
1'8'0
WEST ELEVATION
UV BUILDING ELEVATIONS
Page 13
N
C
A
M
PB
ELL
R
D
DURFEE AV
IDAHO ST
W 3RDAVFOSTER ST
KNAPP ST D E M P S E Y T R
KNAPP ST
WITZEL AV
FVTCAthleticField
Seniors Center
Boat Launch
U
W
-
O
Riv
erfro
nt/J
a
c
o
b
S
h
a
piro P
a
J:\GIS\Planning\Plan Commission Site Plan Map Template\2023 Plan Commission Site Plan Map Template.mxd User: katrinam
Prepared by: City of Oshkosh, WI
Printing Date: 10/29/2025
1 in = 360 ft1 in = 0.07 mi¯233 N CAMPBELL RDNOTICE MAP
City of Oshkosh maps and data are intended to be used for general identification purposes only, and the City of Oshkoshassumes no liability for the accuracy of the information. Those using the information are responsible for verifying accuracy. Forfull disclaimer please go to www.ci.oshkosh.wi.us/GISdisclaimer
Page 14
N C
A
M
P
B
E
L
L R
D
KNAPP ST
DE M PSEY TR
WITZEL AV
IDAHO ST
KNAPP ST D E M P S E Y T R
N CAMPBELL RD
N C
A
MPBELL RD
WITZEL AV
KNAPP ST
I
I-PD
I-PD
MR-12
RMU
SR-9
UI
UI
UI-PD
UMU
UMU
J:\GIS\Planning\Plan Commission Site Plan Map Template\2023 Plan Commission Site Plan Map Template.mxd User: katrinam
Prepared by: City of Oshkosh, WI
Printing Date: 10/29/2025
1 in = 260 ft1 in = 0.05 mi¯233 N CAMPBELL RDZoning & Aerial Map
City of Oshkosh maps and data are intended to be used for general identification purposes only, and the City of Oshkoshassumes no liability for the accuracy of the information. Those using the information are responsible for verifying accuracy. Forfull disclaimer please go to www.ci.oshkosh.wi.us/GISdisclaimer
Page 15