HomeMy WebLinkAbout0112212-Building � `
CIT�! OF�,�HKOSH �;e:°-�'�'�v�o�o ������
OSHKOSH BUILDING PERMIT APPLICATION AND RECOR F� sr� .
ON THE WATER OqT�
Job Address 90 92 GIBSON CT Owner CHRISTOPHER LEITCH Create Date 12/13/2004
Designer Contractor OWNER
Category 120-New Duplex Plan F1-116-1004R
Type � Building � Sign � Canopy � Fence � Raze
--— - --�
Zoning R-2 Class of Const: VB Size 46'x 82'
Unfinished/Basement 2456 Sq.Ft. Rooms 3 Height 21 Ft. � Projection_�
Finished/Living 2585 Sq.Ft. Bedrooms 2 Stories 1 Canopies 0
Garage 836 Sq.Ft. Baths 2 Signs 0
Foundation � Poured Concrete � Floating Slab 0 Pier � Other
� Concrete Biock 0 Post � Treated Wood ---
Occupancy Permit Required Flood Plain No Height Permit Not Required
Park Dedication Required #Dwelling Units 2 #Structures 1
Use/Nature 'New Duplex/ New duplex with attached garage,driveways,and patioa as per plan.
of Work
HVAC Contractor CONDON TOTAL COMFORT Plumbing Contractor MIKE MILHAUPT
Electric Contractor CUMINGS ELECTRIC INC
Fees: Valuation $154,900.00 Plan Approval $75.00 Permit Fee Paid $574.00 Park Dedication $330.00
Issued By: � Date 01/05/2005 FinallO.P. 00/00/0000
❑ Permit Voided Parcel Id# 1413343600
In the performance of this work i agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party,if you perform the work
described in this permit application within an easement,the City strongly urges the permit applicant to contact the easement
holder(s)and to secure any necessary ap r re starting such activity.
Signature - Date "s'��
AgenUOwner
Address Oshkosh WI 54901 - 0000 Telephone Number
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number,Type of
inspection(i.e. Footing,Service, Final,etc.),Access into Building if Secure(how do we gain entry),your Name and Phone
Number. Unless specifed otherwise,we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
� . , . ,
OSHKOSH GRADE STAKE FORM 5��v
ON THE WATER Grade Stake u� � 6
�
O
Name CHRISTOPHER LEITCH Address 90 92 GIBSON CT Cre 12/13/2004
Lot 3 Block Ward
Subdivision Stoney Beach West Zone
Street Number Lot Dimensions IRRG Sidewalk Existing
Building Grade Elevation Stakes Set At Site 12/15/2004 Set By D.W.G. BK-601, P-50
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade established bef avation
has commenced. _
Wisconsin De artment of Indust A lication No.
Laborand Human Relations ry WISCONSIJV UNIFORM PP SGAiy�
Saferyand Buildings Division BUILDING PERMIT o��22�2 R`
P.O.Box 2509 APPLICATION Parcel No.
Madison,WI 53701-2509 Oqr
Wisconsin Statues 101.63, 101.73
Q✓ Constr � HVAC � Elec � Pibg �✓ Erosion ❑ Other:
Owner's Name Mailing Address Telephone No.
CHRISTOPHER LEITCH 1188 CAMBRIA CT Oshkosh WI 54904- 0000
Contractor: ✓ Con� Elec� HVAC Plbg LiGCert# Mailing Address Telephone No.
OWNER Oshkosh WI 54901 -0
Contractor: Con ✓ Elec HVAC Plbg LiGCert# Mailing Address Telephone No.
CUMINGS ELECTRIC INC 170792 PO BOX 749 NEENAH WI 54957 -749 920-722-1240
Contractor: Con Elec ✓ HVAC Plbg LiGCert# Mailing Address Telephone No.
ONDON TOTAL COMFORT 3202 PO BOX 184 RIPON WI54971 -184 920-748-5050
Contractor: Con Elec HVAC ✓ Pibg LiGCert# Mailing Address Telephone No.
MIKE MILHAUPT 230863 1226 CHELSEA CT MENASHA WI 54952 -0 920-749-9121
„����_� Lot Area S .ft. 1/4, 1/4,Section ,T N,R E(or)W
Building Address Subdivision Name Lot No. Block No.
90 92 GIBSON CT Stoney Beach West 3
Zoning District(s) Zoning Permit No. Front Rear Left Right
� ���p
✓ New � Repair Single Family Entrance Panel ✓ Forced Air Furnace Fuel Nat. L.P. Oil Elec. Solid Sola
� Alteration � Raze `� Two Family Size: 200 am ❑ Radiant Baseboard or Panei Gas *
� Addition B Garage Service: � Heat Pump Space Htg Q✓ ❑ ❑ ❑ ❑ ❑
� Move � Other(print): � Overhead � goiler Water Htg �✓ � � � � �
�✓ Underground
� Other: �✓ Central Air Conditioning * pwelling unit will have 3 kilowatt or
Other more installed electric space heating equip.
�✓ Site Constructed Concrete Infiltration control option is:❑ Full sealing
Manufactured ❑ Masonry
Unfinished ❑ Sewer of joints. ❑ Blower door test. ❑ Exterior
� Treated Wood
Basement 2456 Sq.ft. : �✓ Municipai air infiltration barrier.
✓ 1-Sto ❑ Other Se tic p �
Living Area 2585 Sq.ft. ry ❑ P�
� 2-Story Permit No. Envelope 19858 BTU/HR
Garage $36 Sq.ft. � Seasonal 14749
� Other Infiltration BTU/HR
�✓ Permanent � Municipal Utility
� Plus Basement ❑ Other � private On-Site Well $154,900.00
The applicant agrees to comply with all applicable codes,statues and ordinances and with the conditions of this permit,understands that the issuance of
the permit creates no legal liability,express or im lied,on the Dep nt or municipality;and certifies that all the above information is accurate.
APPLICANT'S SIGNATURE DATE SIGNED �f—D�
APPROVAL CONDITIONS This permit is issued pursuant to the following conditions. Failure to comply may resuit in suspension or
revocation of this permit or other penalty
See standard conditions of approval
� Town � Village �✓ City � County State of: Municipality Number of Dwelling Location:
City Of Oshkosh 7 0 - 2 6 6
Plan Review $75.00 `� �nstruction
HVAC Name Brian Noe
Inspection Electrical
Wis.Permit Seal $30.00 � Plumbing Date 12/13/04
Other 0✓ Erosion
Total $105.00 ❑ 326576 Cert.No. 70266
SBD-5823(R.07/92)
� � . < < gGAH�
OSHKOSH PARKLAND DEDICATION FEE COLLECTION RECORD ��S�o
ON THE WATER �
4
Job Address 90 92 GIBSON CT Date 01/05/2005
Name CHRISTOPHER LEITCH
Address 1188 CAMBRIA CT Oshkosh WI 54904
Subdivision Stoney Beach West Lot 3
Building Permit Number 0112212
Number of Dwelling Units 2 Number of Structures 1
Fee Required $330.00 Fee Paid
Owner's Signature � Date ��S��
Inspector's Signature Date
� . �
' • < .
< • •
:,
f
�
CITY OF OSHKOSH
,
STANDARD CONDITIONS OF APPROVAL
; Project Address_ q� 9Z
"o���G� Permit#
; Please read the following information and sign at the bottom to acknowledge that you have read
� and agree to comply with these conditions.
�
�
� 1. All habitable rooms must be provided with 8%light and 3.5%ventilation. Bedrooms
� located on the second floor or below ground level must be provided with egress windows
� in addition to the light and ventilation requirements. Basement windows are also
� required to have window well areas in accordance with ILHR 21.03.
;
,
a
= 2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
; The door and frame assembly between the dwelling unit and an atta.ched garage shall be '
� labeled by an indenendent testin�gencv as having a minimum fire-resistive rating of 20
i minutes. All drywall joints are required to be taped/sealed unless the joints aze fitted so
that the gap is no more than a dimes thickness( 1/20-inch)and backed by solid wood or
drywall with the joints staggered.
3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces. :
4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
5. Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
6. All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
8. Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans,microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
�
9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses �
and TJI's must be designed for the cantilevered areas. �
�
�
�
�
�
% -
a
� • � , �
� �
�
� '
� .
� 10. The property owner and applicant is responsible for compliance with ILHR 21.125
� (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
� required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20'width. Erosion
; control measures must be maintained until the lawn is established.
�
i
� 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment)must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
I
12. The building placard must be posted on site at all times. Once the rough framing is up
� the placard must be posted on the patio door or on a kitchen window. If the placard is not
! present at any inspection, stop work orders will be posted. Additional placards can be
� obtained through our department if the cazds are misplaced.
0
i
� 13. All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals aze not roughed in, the inspection will fail and a$100
� re-inspection fee will be charged.
�
i
F 14. Attached is a copy of the final inspection checklist. At the final inspection all items on
�
i this list must be completed to avoid the$100 re-inspection fee per inspection.
� 15. When requesting final inspections please note that a minimum of 2 days notice is needed
i
� from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the gazage floor and a minimum of a 3'pathway must be provided around the walls of
the gazage. At the final inspection no fizrniture or personal belongings are allowed in the
'' house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
,
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16. The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
� final inspection approved stickers on the backside. If occupancy occurs prior to the
� inspections being approved daily citations will be issued with no further notice being
� given.
��
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor. �
j �i�ncsfure o�.�pp�curcf: e[Jafe: ��s�.s
I
;
i
I
i
�
i
ZONING/LAND USE COMPUANCE CHECKLiST :
JOB LOCATION: `I � t `��2 _ l'T�I�s� �� ZONING �
PROPERTY OWNER/CONTRACTOR:
CONSTRUCTION DATA: � New Construction Addition __ Alteratian
TYPE OF CONSTRUCTION: (i.e. fence, pool, parking lot, sign, etc.) �U� t�
COMPLIANCE CHECKLIST
DEFICIENT COMMENTS
Use �rt� �c�N .ls �t-�,6� SH��+
Lot Width �
Lot Area f
Lot Area Per Family w! �J�� i�l�N S
Floodpfain
Front Yard
Front Yard Side Street
Rear Yard
Side Yards
Building Area
Parking Standards
Off-Street Loading Standards
Vision Ctearance _
Transitional Yard Standards
Landscape Standards
Height
Conditions of Approval
Compliance with P.C. or
BZA Conditions of Approval �
Signage Standards
Drainage Plan
REVIEW AUTHORITY
As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or
designee, must approval all pians, except the following: (1) Alterations or interior woric when the use is
conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc.,
when the use is confoRning and when no change is proposed.
�,_ APPROVED DENIED
Plan Commission Action Required
Vanance(s) Required
REVIEWED BY: DATE: ��—Z(� y_
GIBSON COURT
RB5 .00 I
251
25' BmLDING-
SETBA CKLlliE
'-'-,
\U
a \Ù
8 \-
-1 ~
2< ~
X <38
\Jì
\U2?žo
~«r-
LL1 ~\U\UD
r-~~
\Uç::~1::
~Uì -1
--! r
~~25
\--lnZ
0... o~~~
~ \U.~ ~
::) t5~~-
øD
~glfì3
1z<\U:i
0 o-D-
\.)~~Ul
-1\-\-~
<~ ~
æ:\)~
~z~\L\
\L1(!) ~
Ølfì-Ö
\L1~\L1
, ~Q\L\~
\-\.)æ:\U
~\LOD
a\) 0
"~\-\)
2 \cl
\--1
t- <2-~
æ: 1:.0
~<~-1
>-lfì<2
;.-a
æ o£ß<
~ \- .~ \L\
\-~\U\-
~<
\L -\-
:) Z(!)Ul
00\1.1
Z \-'~ ~
o~<\-
\- .
0 ùæ:\-1:.-1
\U\- \-<
~lfì2-ù
-z ~~
aSlfì \-
U ~ tfì':ltf3
\-~ztrl
r-ùj82
<ILIL
[1?={Hg<:
~ð~ZD
Z < <l)<
{ba\-tfìt
ß:~~~ci
a \TIgæ:~~
~S~\L3
to Yz~~1L
<UJ \-'
:r:.\L1~~~
lfìtû Ot
(1) ~\U\-\\-<
'> ~
~~IIi?=\L
\---1
lfì~-1<
8-1 tû~
~ :§UJ5£~
\lJaæ:o~
lfì-alL
~'>Uì~
\-~~~tl
~t)
~ ~ ~
~ 4J iiìQ.
c' ,§.. t~. =...i.,ftj....., ..,"
'.~....~...O
~,1~
;c ~ ~
ø...JJ ~
~~
~~
~ ~ tØ
~ =ë ~
~~ ~
~o Q
VJ~
Qi
~~
~
4B1 _o5n
B
ø.
~~
0 0
.0 ù':
Q~
" \-J
'-Q
~
(I:!
~
":r:i
tr1
Z
Q
........ \)fJ
""'0
Po
W '0-
we
- 0\
Ó
0::
t13
,..
511..-1 fE~e
--
--
--
--
---------------------
25'
DRAINAGE EASEMENT
S89°53'54"W
130.02'
I PI-AN NOTES
-
STONEY BEACH WEST
LOT 3
'. '.
.. .
.. .
rroFoseD 51Te FI..-AN 15 BAseD ON THe !-AND 5URvei BY KA. SMITH AS'XXIA res, INC., FL-t::ASE REfEReNCE
1HI5 ORA \VINd fOR 01HeR 5feGlfIGS ~eG^ROIt-(; íHIS I..-OT
w-
.-. ì fl' .
.., '
L. . .
INDEX TO DRAWINGS
CI Site Plan
AI EXTERIOR ELEVATIONS
A2 FLOOR PLAN
A3 FOUNDATION PLAN
A4 SECTIONS
.51 5TRUCTURAL - FIRST FLOOR
S2 STRUCTURAL - ROOF SYSTEM
EI ELECTRICAL - FIRST FLOOR
E2 ELECTRICAL - BASEMENT
DRAWINGS BY
JEFF SLIFE
"{
DATE
SEPTEMBER 30, 2004
DRAWING NO.
D-O4-CONCEPT
GENERAL CONTR.
~c.J"~
BlJJ.L.D£R S Jhv eJ .¡. A. .t
~
OWNER
CJL INVESTMENTS INC.
SCALE
¡II
-
10'011
SITE PLAN
C1
\
PLAN SUBMITTAL CHECKLIST
For 1 and 2 Family Homes
** All drawings must be legible and drawn to scale and dimensioned to include:
Please Note; Missing or incomplete information may delay Plan Approval and Permit Issuance.
1. Buildinl! permit application/information sheet
&r Use Õce Use
2. Plot plan/Site plan indicatinl!:
The location and size of:
D Proposed dwelling including all exterior dimensions
D All buildings including any existing structures
D Accessory structures
D Driveways, patios, decks, fences, and pools
D Stonn drainage grades and drainage features - For sites/subdivisions subject to an adopted
stonn drainage plan and grading.
~
I5q'
13"
~
ff
Œi
@'
ð
CJj
4.
00 D
[1J D
[2? D
Œ" D
[S( D
13'" D
Ø" D
Q"" D
~ D
0' D
]J D
0 D
NOTE: All setbacks must be clearly labeled on the site plan. It is suggested site plans be
drawn on City GIS site plans.
3.
D
D
D
D
Erosion control plan indicatinl!:
Location of erosion control measures for sediment control
Location of gravel access drive
Location oftemporary soil storage piles
Location of any other planned / required erosion control measures
NOTE: A separate copy of the site plan with this additional infonnation may be used for
this erosion control plan.
Floor plans indicatinl!: (two copies)
The size and location of:
Rooms
Doors
Room use (kitchen, dining, family, bedroom, etc.)
Smoke detectors
Windows
Structural features- size, species and grade of lumber and other structural
máterials used for joists, beams, rafters, trusses, headers, studs, and columns.
NOTE: Beam calculations are required for any beams with point loads on them.
Exit passageways (hallways) and stairwells
Plumbing fixtures (bathroom, kitchen, etc.)- lavatory, water closet, water heater,
softener, etc.
Chimney(s)- include also the type of construction (masonry or factory built) and
rating, if metal.
Beatin~. equipment .
Attic arid crawl spàèe access
Fire separation between dwelling and garage
5.
8J D
~ D
~ D
6.
¡if D
IT' D
~ D
~ D
Q( D
Bf" D
~ D
&' D
[] D
df D
7.
¡if D
ß/ D
ŒY D
rf~
~ D
~ D
~ D
~ D
[( D
¿~
Truss plans includilll!::
A truss layout drawing indicating how the trusses will be installed.
A truss design plan for each truss with all infonnation required by TPI. This infonnation
may be provided at the rough framing inspection.
Connection details for all truss / framing connections
Foundation plans indicatinl!:: (two copies)
The size and location of:
Structural features- strength, thickness, and reinforcement (if any) of concrete for footings,
foundations, floors and any other concrete work; height and thickness of concrete and/or
masonry construction
Footings
Column pads - Calculate size of pad canying the most load.
Wall construction
Beams
All dimensions
Plumbing fixtures
Service panel
Sump pit
Furnace
Elevation plans indicatinl!:: (two copies)
Dwelling height
fufonnation on exterior appearance
fudicate the location, size and configuration of doors, windows, roof, chimneys and exterior
grade level
Cross-sectional drawinl!: indicatinl!:: (two copies)
Exterior finish grade level
Footing and foundation wall sizes, drain tile system and type of materials (Must be sized to
carry anticipated loads- NOT just minimum code req.)
Exterior wall construction identifying materials used (including insulation, vapor banier,
wall sheathing, stud spacing)
Stair dimensions- riser heights, tread widths, headroom, handrail and guardrail heights
Roof construction identifying type of material, size, and spans (including insulation, vapor
banier, roof sheathing, and rafter/truss spacing)
Floor construction identifying type of material, size, and spans (including insulation)
Heat loss calculations
Accurate infonnation, correct square footage, and insulation values
DATE:
/ ¿¡'-If-~
PROJECT ADDRESS:
r' C(JU~