Loading...
HomeMy WebLinkAbout0111976-Electric e OSHKOSH ON THE WATER CITY OF OSHKOSH No 111976 ELECTRIC PERMIT - APPLICATION AND RECORD Job Address 0 Change 0 Temp Owner BANNER PACKAGING INC Create Date 12/06/2004 Category 653 - Industrial-Addition/Remodels Plan 10 Overhead . N/A Type 0 Underground Circuits 155 Fixtures 880 Switches 32 Receptacles 200 3550 MOSER ST Contractor SUBURBAN ELECTRICAL ENGINEERINC Service 10 New Volts 480/277 Amps 0 Appliances Use/Nature of INO / Building wiring for the addition. Work Fees: Valuation $363,900.00 Plan Approval $0.00 Permit Fee Paid $1,276.00 Issued By: Date 12/13/2004 U Permit Voided I Parcelld # 1519606900 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address 709 HICKORY FARM LN APPLETON WI 54914 - 0 Telephone Number 920-739-51 56 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. J"b Address 3550 MOSER ST .' ) Electric Permit Work Card Permit Number ~ Create Date 12/06/2004 OWner BANNER PACKAGING INC Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels 0 ChangeO Temp. N/A I Type 0 Overhead Circuits 155 Fee $1,276.00 0 0 Underground . N/A Fixtures 880 Receptacles ~ Value $363,900.00 Service p New Volts 480/277 Amps 0 Switches 32 Appliances Use/Nature of Work IND / Building wiring for the addition. Inspections: Date 12/15/2004 Type Note Inspector Kevin Benner no time FORWARDED FROM KB REQUEST FOR UNDERGROUND INSPECTION NO PERMIT, PANEL FEEDS INSIDE & RUNNER PIPES TO GENERATOR OUTSIDE Date/Time requested: 12/06/2004 08:14 PM Access: Notice Type: Phone Number: SCOTT 841-7096 Ready Date/Time: 12/06/200408:14 PM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - -. Date 01/25/2005 Type Rough In Inspector Kevin Benner approved discussed the future UG conduits with metallic elbows in the next section, wiring metods for daisy chained lights above the ceilings, box bonding, generator, UPS, and NEC 240.21 tap rules, seperately derived system wimg from a XFMR & Generators. Date/Time requested: 01/24/2005 09:22 AM Access: Will be on site Notice Type: Phone Number: 841-7096Scoll Ready Date/Time: 01/25/200509:22 AM Requested by: -- 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --. Job Address 3550 MOSER ST OWner BANNER PACKAGING INC Electric Permit Work Card Permit Number ~ Create Date 12/06/2004 Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels Service p New 0 ChangeO Temp. N/A I Type 0 Ovemead Volts 480/277 Circuits 155 0 Under9round . N/A Fixtures ~ Receptacles ~ Value $363,900.00 Amps ~ Switches 32 Fee $1,276.00 0 Appliances Use/Nature of Work IND / Building wiring for the addition. Inspections: Date 02/08/2005 Type Underground Inspector Kevin Benner approved w/cond. The installation was not complete. Discussed the installation of ridgid conduit to the panel for grounding purposes. Date/Time requested: 02/07/2005 03:08 PM Access: Notice Type: Phone Number: Scott841-7096 SUBURBAN ELECTRICAL ENGINEERING Ready Date/Time: 02/08/2005 00:00 00 Requested by: -- 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid ------------ -- - - ----- - - ------------------ -------------- ------------------------- ---. Date 02/08/2005 Type Rough In Inspector Kevin Benner not approved The east bathroom MC cable support is to be secured to the grid Date/Time requested: 02/08/2005 11 :00 AM Access: Notice Type: Phone Number: Ready Date/Time: 02/08/2005 11 :00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - -. Job Address 3550 MOSER ST Electric Permit Work Card Permit Number 111976 CreateDate 12/06/2004 OWner BANNER PACKAGING INC Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels Service p New 0 ChangeO Temp. N/A I Type 0 Ovemead Volts 480/277 Circuits ~ 0 Underground. N/A Fixtures 880 Amps 0 Switches ~ Receptacles 200 Appliances Fee $1,276.00 0 Value $363,900.00 Use/Nature of Work IND / Building wiring for the addition. Inspections: Date 02/15/2005 Type Consultation Inspector Kevin Benner approved w/cond. Reviewed the location of the temporary generator for temporary wiring possibilities Must be done with a raceway or PVC coated MC cable. Date/Time requested: 02/14/2005 03:20 PM Access: Notice Type: Phone Number: 841-7096Scott Ready Date/Time: 02/15/2005 00:00 00 Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING -----------------------------------------------------------------------------------. Date 02/17/2005 Type Rough In Inspector Kevin Benner approved Tenminating feeders Reviewed the underground for the loading docks, generator wiring,fire alarm wiring, exterior emergency lighting and necessary wiring for a temporary occupancy Date/Time requested: 02/14/2005 03:20 PM Access: Notice Type: Phone Number: 841-7096Scott Ready Date/Time: 02/16/2005 00:00 00 Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING -----------------------------------------------------------------------------------. Job Address 3550 MOSER ST Electric Permit Work Card Permit Number ~ Create Date 12/06/2004 Owner BANNER PACKAGING INC Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels Service p New 0 ChangeO Temp. N/A I Type 0 Overhead Volts 480/277 Circuits ~ 0 Underground . N/A Fixtures 880 Receptacles ~ Value $363,900.00 Amps 0 Switches 32 Fee $1,276.00 0 Appliances Use/Nature of Work IND / Building wiring for the addition. Inspections: Date 02123/2005 Type Final Inspector Kevin Benner approved w/cond. Temporary Conditional Approval Arc Flash Warning Labels, RTU disconnect height, Buried receptacal box on the mezzanine, sheet metal screws used for grounding, FACP not installed (reviewed the NFPA 72 req.), temp generator, North 1/2 of the building only.2/23/05 3:10 Pm Scott Westphal called & stated that the vio.'s have been corrected. Date/Time requested: 02122/2005 12:37 PM Access: Notice Type: Phone Number: 841-7096 Scott Ready Date/Time: 02/23/2005 00:00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - -- - - - - - - - - - - - - - - - - - - - - - - - - -. Date 03/08/2005 Type Rough In Inspector Kevin Benner approved Office area / One side is drywalled, but it will be one-two weeks before it will be insulated Date/Time requested: 02/24/2005 03:32 PM Access: Notice Type: Phone Number: 841-7096 Scott Ready Date/Time: 02124/2005 03:32 PM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid -----------------------------------------------------------------------------------. Job Address 3550 MOSER ST Electric Permit Work Card Permit Number 111976 Create Date 12106/2004 OWner BANNER PACKAGING INC Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels Service p New 0 Change 0 Temp. N/A I Type 0 Overhead Volts 480/277 Circuits 155 0 Underwound . N/A Fixtures 880 Amps ~ Switches ~ Receptacles 200 Fee $1,276.00 0 Value $363,900.00 Appliances Use/Nature of Work IND / Building wiring for the addition. Inspections: Date 04/06/2005 Type Abv Ceiling Inspector Kevin Benner approved w/cond. South offices connect the wires supporting the wiring methods above the ceiling to the grid. Approved to install the ceiling tiles. Date/Time requested: 04/06/2005 07:18 AM Access: Notice Type: Phone Number: 841-7096 Scott Ready Date/Time: 04/06/2005 11 :00 AM Requested by: -- 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid -----------------------------------------------------------------------------------. Date 04/06/2005 Type Rough In Inspector Kevin Benner approved Lunch Room & adjacent offices Date/Time requested: 04/06/2005 07:18 AM Access: Notice Type: Phone Number: 841-7096 Scott Ready Date/Time: 04/06/2005 11 :00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid -----------------------------------------------------------------------------------. Job Address 3550 MOSER ST Electric Permit Work Card Permit Number 111976 Create Date 12/06/2004 Owner BANNER PACKAGING INC Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels $1,276.00 0 0 Underground . N/A Fixtures 880 Receptacles 200 Value $363,900.00 Service p New 0 ChangeO Temp .N/A I Type 0 Overhead Volts 480/277 Circuits ~ Amps 0 Switches ~ Fee Appliances Use/Nature of Work IND / Building wiring for the addition. Inspections: Date 04/06/2005 Type Service Inspector Kevin Benner not approved Pemenant Generator The generator transfer time is 40% to slow. Date/Time requested: 04/06/2005 07:19 AM Access: Notice Type: Phone Number: 841-7096Scott Ready Date/Time: 04/06/200511:00 AM Requested by: -- 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -. Date 04/14/2005 Type Rough In Inspector Kevin Benner approved Date/Time requested: 04/14/2005 01:14 PM Access: Notice Type: Phone Number: 841-7096 Scott Ready Date/Time: 04/14/200501:14PM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING --- --------------- ------------------- ------ - - - ---------------- - - ---- --- ------------. Job Address 3550 MOSER ST Electric Permit Work Card Permit Number 111976 Create Date 12106/2004 OWner BANNER PACKAGING INC Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels 0 ChangeO Temp. N/A I Type 0 Overhead Circuits ~ 0 Underground. N/A Service p New Volts 480/277 Amps 0 Fee $1,276.00 0 Fixtures 880 Receptacles 200 Value $363,900.00 Switches ~ Appliances Use/Nature of Work IND / Building wiring for the addition. Inspections: Date Type Final Inspector Kevin Benner Request from the Building Inspector Date/Time requested: 05/11/2005 08:10 AM Access: Notice Type: Phone Number: Ready Date/Time: 05/16/200502:00 PM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid - -------- ----------- - --- - - ------ - ------------- ---------------- ---------------------. Date 05/16/2005 Type Final Inspector Kevin Benner not approved compactor disconnects, dock iock fiexible cord, identify branch circuit color coding at paneiboards, working space for RTU disconnects, FACP NFPA 72 identification requirements Date/Time requested: 05/11/2005 01 :41 PM Access: Notice Type: Phone Number: 841-7096 Scott Ready Date/Time: 05/16/200502:00 PM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - -. Electric Permit Work Card Job Address 3550 MOSER ST Permit Number ~ Create Date 12106/2004 OWner BANNER PACKAGING INC Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels Service p New 0 ChangeO Temp . N/A I Type 0 Ovemead 0 Underground . N/A I Volts 480/277 Circuits 155 Fixtures ~ Amps ~ Switches 32 Receptacles ~ Fee $1,276.00 0 Value $363,900.00 Appliances I I Use/Nature IND / Building wiring for the addition. of Work Inspections: Date 05/16/2005 Type Consultation Inspector Kevin Benner approved Review wiring requirements for the office area. Date/Time requested: 05/16/2005 03:30 PM Access: Notice Type: Phone Number: Ready Date/Time: 05/16/200503:30 PM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -. Date 05/17/2005 Type Reinspect Inspector Kevin Benner not approved Check the transfer tirne for the emergency generator Transfer delay is 13.25 Seconds DatelTime requested: 05/16/2005 03:30 PM Access: Notice Type: Phone Number: 450-5234 Travis SUBURBAN ELECTRICAL ENGINEERING Ready DatelTime: 05/17/200500:00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -' Electric Permit Work Card Job Address 3550 MOSER ST Permit Number 111976 Create Date 12/06/2004 OWner BANNER PACKAGING INC Contractor SUBURBAN ELECTRiCAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels Service pNew 0 ChangeO Temp .N/A I Type 0 Overhead 0 Underground. N/A J Volts 480/277 Circuits 155 Fixtures 880 Amps ~ Switches ~ Receptacles 200 Fee $1,276.00 0 Value $363,900.00 Appliances I I Use/Nature IND / Building wiring for the addition. of Work Inspections: Date 05/17/2005 Type AbvCeiling Inspector Kevin Benner approved Lunch room and the two offices immediately adjacent DatelTime requested: 05/17/2005 00:00 AM Access: Notice Type: Phone Number: 450-5234 Travis Ready Date/Time: 05/17/200500:00 AM Requested by: -- 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid -----------------------------------------------------------------------------------. Date 05/18/2005 Type Abv Ceiling Inspector Kevin Benner approved I""~"" Date/Time requested: 05/17/2005 00:00 AM Access: Notice Type: Phone Number: 450-5234 Travis Ready Date/Time: 05/18/200500:00 PM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING -----------------------------------------------------------------------------------. Job Address 3550 MOSER ST Electric Permit Work Card Permit Number 111976 Create Date 12106/2004 Owner BANNER PACKAGING INC Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels Circuits I Type 0 Overhead 155 0 Underground . N/A Fixtures 880 Receptacles 200 Value $363,900.00 Service 10 New Volts 480/277 Amps 0 0 ChangeO Temp. N/A Switches ~ Fee $1,276.00 0 Appliances Use/Nature of Work IND / Building wiring for the addition. Inspections: Date 06/14/2005 Type Final Inspector Kevin Benner not approved TRANSFERED TO REQUEST LNE FROM X 5046,6/9 @ 7:18 AM / WOULD LIKE INSPECTION 6/9 IF POSSIBLE Need to rewire the dock locks Need emergency illumination in the conference room Daterrime requested: 06/08/2005 01 :58 PM Access: Meet Travis (450-5234) on site 6/14/511:30 AM Ready Daterrime: 06/08/2005 01 :58 PM Requested by: -- 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Notice Type: Phone Number: SCOTT 841-7096 SUBURBAN ELECTRICAL ENGINEERING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - -. Date 07/19/2005 Type Re Final Inspector Kevin Benner approved I--~ Date/Time requested: 07119/2005 01 :28 PM Access: Notice Type: Phone Number: Ready Daterrime: 07/19/200501:28PM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid -----------------------------------------------------------------------------------. 'Job Address 3550 MOSER ST Owner BANNER PACKAGING INC Electric Permit Work Card Permit Number 111976 Create Date 12106/2004 Contractor SUBURBAN ELECTRICAL ENGINEERIN( Category 653 - Industrial-Addition/Remodels Service p New 0 ChangeO Temp. N/A Volts 480/277 Circuits I Type 0 Overhead 155 0 Underground . N/A Fixtures ~ Receptacles ~ Value $363,900.00 Amps Switches 32 Fee $1,276.00 0 Appliances Use/Nature of Work IND / Building wiring for the addition. Inspections: Date 08/10/2005 Type Re Final Inspector Kevin Benner not approved Request Line - Wed lunch or shortly after. I could not get in the addition and myself or Scott could not get in touch with Travis to conduct the inspection. DatelTime requested: 08/09/2005 09:16 AM Access: Notice Type: - Phone Number: 841-7096 Ready DatelTime: 08/10/200512:00 PM Requested by: -- 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING -----------------------------------------------------------------------------------. Date 08/25/2005 Type Re Final Inspector Kevin Benner approved DatelTime requested: 08/23/2005 08:26 AM Access: Meet Scott and Travis on site Notice Type: Phone Number: Ready DatelTime: 08/24/2005 07:00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid SUBURBAN ELECTRICAL ENGINEERING --- -- ----------- ----- ----- -- --- --- ----------- -------------- ----- ------- ------------.