HomeMy WebLinkAbout0111726 E
e
OSHKOSH
ON THE WATER
CITY OF OSHKOSH
No
111726
ELECTRIC PERMIT - APPLICATION AND RECORD
Job Address
Service
10 New
120/240
0 Change
0 Temp
Owner WINNEBAGO COUNTY Create Date 11/18/2004
Category 642 - Commercial-New Building Wiring Plan
10 Overhead
. N/A Type 0 Underground
Circuits 0 Fixtures 4
Switches 0 Receptacles 8
453 AVIATION RD
Contractor
HOEHNE ELECTRIC
Volts
Amps
200
Appliances
Use/Nature of Comm/ Wire new airplane hanger
Work
Fees: Valuation
$2,500.00
Plan Approval
$0.00
Permit Fee Paid
$82.00
Issued By:
Date 11/18/2004
U Permit Voided I
Parcelld # 1413530000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
Signature
Date
Agent/Owner
Address
W599 STATE RD 21
BERLIN
WI 54923 - 0
Telephone Number
800-603-7242
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
< ~ Electric Permit Work Card
Job Address 453 AVIATION RD Permit Number ~ Create Date 11/18/2004
Owner WINNEBAGO COUNTY Contractor HOEHNE ELECTRIC
Category 642 - Commercial-New Building Wiring
Service b New. 0 ChangeO Temp . N/A I Type 0 OVe!l1e_acl.~-O underground. N/A I
Volts 120/240 Circuits 0 Fixtures 4
-
Amps ~ Switches 0 Receptacles 8
-
Fee ~ D Value $2,500.00
Appliances I I
Use/Nature omm/ Wire new airplane hanger
of Work
Inspections:
Date 11/1812004
Type Service
Inspector Kevin Benner
not approved
Tried to fax to the E.C., but the call would not go through 11118/04. I did leave a notice on site at the electrical
panel.
11/221047:50 AM, called Curt Hoehne
Notice Type: FC
Phone Number:
DatelTime requested: 11/18/2004 08:52 AM
Access:
open
Ready DatelTime: 11/18/200408:52AM Requested by:
0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid
- -------- - --- - - - - - ----- -- --- ---- --- -- ---- - - ---- - - -- ------- ------ - - - ----------------.
Date 11/29/2004
Type Re Service
Inspector Kevin Benner
approved wieand.
Need arc Flash Warning Labels
Faxed to WPS 11/30/04, Mailed 12113/04
Notice Type:
Phone Number:
Date/Time requested: 11/29/2004 12:37 PM
Access:
Side door will be open
Ready DatelTime: 11/29/200412:37 PM Requested by:
0 Reinspect Fee 0 Fee Wavled D Reinspect Fee Paid
-----------------------------------------------------------------------------------.
Job Address 453 AVIATiON RD
Electric Permit Work Card
Permit Number ~ CreateDate 11/1812004
Contractor HOEHNE ELECTRIC
Owner WINNEBAGO COUNTY
Category 642 - Commercial-New Building Wiring
Service b New. 0 ChangeO Temp 8N/A I Type 0 Overhead
Volts 1201240 Circuits 0
Amps ~ Switches ~
0 Underground 8 N/A
Fee
~D
Fixtures 4
Receptacles ~
Value $2,500.00
~"-\
Use/Nature
of Work
omml Wire new airplane hanger
Inspections:
Date 12/1312004
Type Finai
Inspector Kevin Benner
not approved
Arc Flash Warning Labels. aHD wiring (cords), Emergency Illumination.
Note: the bathroom will not be done at this time
Reviewed with Curt Hoehne
Hanger was occupied at the time of inspection
DatelTime requested: 12/10/2004 08:37 AM
Access:
Meet Curt H. on site 12/13/041:45 PM
Notice Type:
Phone Number:
Ready DatelTime: ~~ Requested by:
0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - -.
Date 12/30/2004
Type Final
Inspector Kevin Benner
approved w/cond.
Did not have the Arc Flash Waming Labe Installed
Flexible eard to be removed from the aHD
Curt Hoehne stated this would be done today, said he would call when this is eampieted.1213010410:18 AM
Curt Hoehne called and stated that the violations are earrected.
Notice Type:
phone Number:
Date/Time requested: 12/29/2004 12:11 PM
Access:
Ready Date/Time: 12/3012004 ~ Requested by:
0 Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid
-----------------------------------------------------------------------------------.