HomeMy WebLinkAbout0111565-Plumbing (interior)
e CITY OF OSHKOSH No 111565
OSHKOSH PLUMBING PERMIT - APPLICATION AND RECORD
ON THE WATER
Job Address 1140 JUDY LEE DR Owner RUSCH HOMES LLC Create Date 10/07/2004
Contractor PLUMBING CONTRACTOR SPECIALISTS, LLC Category 410 - Residential-Interior Plan
Bathtub 2 Shower 0 Ejector/Grind 0 Dip Well 0 F Prep Sink 0 Gar Drain 0
- - - - - -
Whirlpool 0 Floor Drain 1 Water Softner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0
Lavatory 2 Lndry Tray 0 Local Waste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0
- - - - - -
Toilet 2 Lndry Stndp 1 Clothes Wshr 0 Ice Chest 0 Flr/Wst Sink 0 Int Grease Trap 0
-
Res. Sink 1 Disposal 1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0
- - - - - -
Bar Sink 0 Dishwasher 1 Beer Tap 0 Sculry Sink 0 Wash Ftn 0 RPZ Valve 0
- -
Water Heater 1 Sump Pump 1 Dent. Oper. 0 Hand Sink 0 Urinal 0 Eye Wash Statn 0
- - - - -
Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
- - - - -
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 1
Use/Nature NSFR/ New single family
of Work
Size
Material
Type
#
Conn. Type
Sanitary Sewer
0
0
0
0
0
Storm Sewer
0
0
0
0
0
Water Service
0
0
0
0
0
Parcelld #
134250440
$98.00 U Permit Voided I
Valuation
$5,400.00
Plan Approval
$0.00
Permit Fees
Issued By
Date 11/09/2004
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the
easement holder(s) and to secure any necessary approvals before starting such activity.
Signature
Date
Address
1226 CHELSEA CT
Agent/Owner
MENASHA
WI 54952 - 0000
Telephone Number
920-749-9121
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
~~ q f "-'~ (,..../'I'r r....--~t{¡.C"
WATERCALCULATIONWORKSJiEETFOR k?ClSoI..
It /¡t/ .z: It
.~.
',NFORMATION REQUIREDTO CALCULATE WATER SERVICE SIZE ----- .:r..5
1. Demand of building In gallons per minute. WSFU's 2/ = (GPM) /¥-b
2. Difference in elevation from main or external pressure tank to building control valve. (feet) -
3. Size Of the water meter. (When applicable) 5/8" ~ 3/4" 2S. 1" -, 1-1/2" ~2" _,3" _,4" -,6" -'
4. Developed length from main or external pressuretankto building control valVe. (feat) 3 S-
5, Low presslJre at main in s1reet or e~mal pressure tank. (psig) 5:5
~
CALCULATEWATERSER~CEPRESSURELOSS
6,
Low pressure at main in street or external prOOsurð tank. (value of # 5 above)
Water service diameter is I" .Materialis Pðly&yl_t!.- , Pressure loss
per100ft= IZ.S' Ibs.X . j!;' (decimale(¡uiVatentofservicelenglh,i.e.;65ft=.65) '7,37Ç"
(Subtract line 7. from line 6.) subtotal ~B63
~3
7.
8. Determine pre~ure gain or loss due to elevation,
(multiply the value of # :;> above by .434) value of "8"
9, Available pressure after the bldg. controi valve. (Subtract or add line 8, Enter in "6",) subtotal ~
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LoSS(VALUE OF "A")
B, Available pressure afterthe bldg. control valve. (from "9" above) Value of "8" '18.63
~ ~
C. Pressure loss of water meter (when meter is required or installed) Value of "C"
(Subtract line C. from line B.) sul:l1otal '[;.¡; '3
D. Pressure at controlling fixture. Value of"D" 2-0
(Controlling fixture is /)I'e$fu~ bt:t'a..¿~ JH ¡ ~; "j) dl5:' 3
' I/ð("e. (Subtract the value of D.) subtotal
E. Differencein elevation between the building control valve 3/1t
and the controlling fixtUre in feet ~ X .434 psi/ft. Value of "En
(Subtract the value of E.) subtotal ~{, 7,
F.
Pressure loss due to water tre:itment devices, instantaneous
water heaters and backflow preventers which serve the
controlling fixture.
(Pressure t~ due to ¡r/ A )
(Subtract the value of F.)
Value of "F"
subtotal ÔlI. 72..
G.
Developed lengll} ~ bUilding control valve ~ controlling
fixture in feet~ X 1.5
..
.....
å',O
Value of "G" ~
subtotal . 3;;J9 /
Multi:ily by .......12fL
"AU = ~r\
3'
(Water distribution piping materia! is ~ ... M. ..
(Divide by the value of G.)
A.
Pressure available for uniform loss
"2.h
.91t-t"
to.
7.S
Ie,. 0
3'-1.0
~.s:
2..~
~d WOI£Þ:¿0 S00G 60 'q"cJ
~G~6-6Þ¿-æ6: 'ON XOIcJ
: WOdcJ
Fixture Listing
Date: February 9, 2005
Name: PCS Project: NSFR ~
Street: Stroet: 114 lUflY LB$ D~
City: City:
Non Public Use Fixtures
..,~.,. iu~ai
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Bathtub, with or without shower head 1.50 1.50 2.00
1 Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
1 Kitchen Sink 1.00 1.00 1.50
1 Lavatory .50 .50 1.00
2 Bathtub, lavatory and water closet - FT group 4.00 7.00 8.00
1 Shower Stall, lavatory and water closet FT -group 1.50 3.00 3.50
Public Use Fixtures
Hot Cold Total
1 Ice Maker .00 .50 .50
Total Water Supply Fixture Units 10.50 20.50 25.00
17.0 Gallon per minute demand of the building. Predominatly Flush Tank
32.1 Pressure available for uniform loss. For the table use - 33.0
Maxmmun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 g g g g g 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
31
- .3
.~
~~
3
~~ ~,.~
3 s'
~1
~~
1~
WATER DISTRIBUTION DATASHEET
Date: February 9, 2005
Name: PCS
Street:
City:
Street: 1140 JUDY LEE DR
City:
1. 17.0 Gallon per minute buiding demand, predominatly Flush Tank.
2. 53.0 Low pressure at the Main in the Street.
3. .0 Lb loss from a .0 ft difference in elevation from Main in the Street to the Water Meter.
4a. 1.3 Lb loss from a 16.0 ft 1" Copper Tube Type K ASTM B88 water service from the Main in the Street to the curb stop.
Pressure loss detemined using a C value of 150 ,inside diameter of .995 and a velocity of 7.0 ft per sec.
4b. 2.3 Lb loss from a 37.0 ft 1 1/4" PE Tubing CTS ASTM 2737 AWWA C901 water service from the curb stop to the Water Meter.
Pressure loss detemined using a C value of 150 ,inside diameter of 1.060 and a velocity of 6.2 ft per sec.
5. 4.3 Lb loss from a 3/4in Meter
6. 45.1 Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
A = B- C+D+E x 100
F
A. 33 Pressure available for uniform loss (psi/100 feet of pipe).
B. 45.1 Lbs of pressure available at the Water Meter.
C. 20.0 Pressure needed at the controlling fixture. T/S FAUCET
D. 3.9 Lb loss resulting from a 9_0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. 66.0 Ft Developed length from the 44.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835