Loading...
HomeMy WebLinkAbout0111395-Building e OSHKOSH ON THE WATER Job Address 645-705 LEEWARD CT WEST CITY OF OSHKOSH No 111395 BUILDING PERMIT - APPLICATION AND RECORD Owner LEEWARD PROPERTIES LLC Create Date 1 0/28/2004 Designer Contractor GANTHER CONSTRUCTION Category 210 - Addition Industrial Plan N4-96-1004 Type 18 Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning Class of Const: 2Bibc Size 1 00x1 00 Unfinished/Basement 0 Sq.Ft. 10000 Sq.Ft. Rooms 0 Height 0 Ft. U Projection 1 Finished/Living Bedrooms 0 Stories 1 Canopies 0 Garage ~ Sq. Ft. Baths 0 Signs 0 Foundation 8 Poured Concrete 0 Floating Slab 0 Concrete Block 0 Post 0 Pier 0 Treated Wood 0 Other Occupancy Permit Required Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures Factory/ 10,000 sf factory addition. * No work to commence above grade until parking lot drainage plans are approved by the City Engineering Division. Use/Nature of Work HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $225,016.00 Plan Approval $0.00 Permit Fee Paid $738.00 Park Dedication $0.00 Issued By: Date 1 0/28/2004 Final/O.P. 00/00/0000 U Permit Voided 1 Parcelld # 1524760000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address 4825 CTY TRK A Agent/Owner OSHKOSH WI 54901 - 0000 Telephone Number 426-4774 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. " ZONING/LAND USE COMPLIANCE CHECKLIST JOB LOCATION: 645 LEEWARD COURT SWANSON WIPER ADDN PROPERTY OWNER/CONTRACTOR: MARTIN/GANTHER CONSTRUCTION DATA: 0 New Construction j¿$ Addition ZONING: M-2 0 Alteration TYPE OF CONSTRUCTION: (i.e. fence, pool, parking lot, sign, etc.) 10.000 SF FACTORY ADDITION. NEW LOADING DOCKS AND PARKING/FIRE LANEITRUCK MANEUVERING AREA COMPLIANCE CHECKLIST DEFICIENT 0 Use 0 Lot Width 0 Lot Area 0 Lot Area Per Family 0 Floodplain 0 Front Yard 0 Front Yard Side Street DEFICIENT 0 RearYard 0 Side Yards 0 Building Area 0 Parking Standards 0 Off.Street Loading Standards 0 Vision Clearance 0 Transitional Yard Standards 0 Parking Lot Lighting DEFICIENT 0 Landscape Standards 0 Height 0 Conditions of Approval 0 Compliance with P.C. or BZA Conditions of Approval 0 Signage Standards 0 Mechanical Equip. Screening 0 Other COMMENTS: . NO LANDSCAPING REQUIRED. . ANY EXTERIOR LIGHTING SHALL COMPLY WITH PROVISIONS SET FORTH IN SECTION 30-35(K) OF THE OSHKOSH MUNICIPAL CODE. LOCATIONS OF ROOFTOP AND GROUND LEVEL MECHANICAL EQUIPMENT NOT PRESENT ON PLANS. ALL ROOFTOP OR GROUND LEVEL MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW OF ADJACENT STREETS. ALL PARKING, MANEUVERINGAND FIRE LANE AREAS ARES ON SITE SHALL BE PAVED IN ACCORDANCE WITH SECTION 30-36(C)(3)(a)(i). . . REVIEW AUTHORITY As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approve all plans, except the following: (1) Allerations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, ~~OO~"")f;~:~:;"-' 0 DENIED - Plan Commission Action Required - BOAIVariance(s) Required :L~ REVIEWED BY: Matt TUC~ DATE: 10/18/2004 2003 <t: 'TI rè..- CLOO E :Je:::0) ~>-'7'7co8 or:l.J")t--,co",: . ::J C t--, 't--, a; e::: .- '7 '7 ..c w 0 I/) . '-1-' :r:Uc~~c 1-1.J")8NNrè ZN 1/)'7«::t: 01 <t: CO :> 0 0 .~ O'7>NNt -0) 0) rè ZN-5;. .E I-"""oa;>< . e::: , >< ..:::L, -I-' ~ ~ <t:o..c :¿~Ô 0 c.: z 0 ¡.....( ~ ~ I \J ~ t) 0 loLl \J rn JJ ~ ~ C ~ Z p¿ E--< ro C/) 0 0 ç.:r.:¡z ¡:.r.. ~tJ) z U E--<Z 0 50 ...... E--< o~ ...... Q ~ u""" Q ~ -< ~ Q" Q ~~ -<en ç.:r.:¡ ~ ~o C/) 0 ¡.....( ç.:r.:¡~ p.... ç.:r.:¡~ 0 ~ ,....JC/) ~ Lf)0 p.... -::j'i 'Ü Z 0 (f) Z ~ ~ (f) DATE 15 OCT 2004 PROJECT NUMBER 04-1037 SHEET A1a ~- PROPERTY UNE 700'-0' --u Ö --u rn S c. z: rn 98.00' 9 0 0 \ 142'-5 314\ ZERO SETBACK' EXISTING 70,000 SQ. FT. BUILDING -$- ¡ 00'-0" FLOOR ELEVATION fiRE LANE (I 50 fT LENGTH AT CENTER UNE) EXI TING HDCP ACCES IBLE RAMPS AN TRUCK DOCK RAM S ' 5'-9" I 1'-0" - -- - 95.00' ~-- EXISTING DroVE AND 'ARNNO 97.00' NEW CONCRETE DOCK RAMPS AND RETAINING WALL LEEWARD COURT WEST ~IOPERrY UNE 5'-0" .t 9G.00' 0- :J 0 cL 19 e::: w :r: ~ Z « 19 \ 95.00' PROJECT DATA: 25 PARKING STALLS 22 EMPLOYEES 25 PARKING STALLS PROVIDED PROPERlY LINE ~ SITE PLAN NEW PAVED DRJVE SCALE: :1" - 40'-D" ~ NORTH PROPERlY LINE z ...... l- e::: « ¿ '7 a 0 N 9 IOU-Oil ;.¿ ~v - i 0<1:0 d:) I (Ü 0- I' C1t I- - 1 íLJ -I l1.J lL.\ CD I~~ DL I I i -a ;AJ O' -a nl ~ 9GI-UI r Z nl 98.0U IOU-Oil 0 1 0 0 9G1_01I , 421-5 3/411 ZERO SETBACK R OlD FI RE LANE ( 150 FT LENGTH AT CENTER LINE) I 97.0U ~ NEW CONCRETE DOCK RAMPS AND RETAINING WALL -1--- - - - - 95.0U 0 _I (j) 9G.OU 521-011 95.0U ~ Z ~LW' . PROPERTY LINE NEW PAVED DRIVE $- EXISTINGDRIVE AND PARKING 25 PARKING STALLS I G21_O" PROPERTY LINE NEW SECURITY LIGHTING TO MATCH EXISTING WE:ST ELEVATION- NEW ADDITION SCALE: 1" - 30'-0" EXISTING BUILDING ) NEW ELECTRIC METER-- \ I I! ! I!:! II'III I II I I I ¡ II I I II I III i I I ¡ I i III I! II II i ¡ IIIII I II' 'I II I[ I I1I1 I1I1 II11 IIII1 , , I ill II ~ '1,i'Ji D I i I I II 1(__.., / / n 0... :::> 0 e::( (!) e::( L1J I J: I- Z <t: (!) . n NEW SECURITY LIGHTING TO MATCH EXISTING DDDD I I EAST ELEVATION SCALE: 1" - 30'-0" z ...... l- e::( <t: ¿ "<j- 0 0 N @ n PROPERTY LINE . 7001-UI . . . --.------- EXISTING 70,000 SQ. FT. BUILDING LÍì IOU-Oil Y FLOOR ELEVATION EXI TING HDCP ACCES IBLE RAMPS. AN TRUCK DOCK RAM S / . PROPERTY LINE 51-U1 . . CJ CJ . . :I: :I: . REVISIONS . « -C ro..- 0..00 E ::)~~ ~ ~~ ~ co ~ l.:)t: ""CO~ t:""""<l) ~ :J .- ~ ~ ..c: L.I.J 0 VI . +J ::t:Ut:c.D(.Ot: -L.I"\°NNro ZN~~~O'\ .-' t: « co :> 0 0 .- l.:)~::>NNt ..~ ~ ro ~N~"":XE I- ..- 0 <l) ro ~. e::=><.:;;t.+J~ «O..c: ~COÔ . 0 . 0.. { ,~ IJ .m ~ t~ CJ) IJ.) u It: III :I: I- ~ Z. ~ C~ ~ ~~ ~ 0-: Z~ .~ H cj ;:; ~' ~ ~ ~ ~ .- > ;...,¡ IJ.) Cf) ..¡....,¡ LEEWARD COURT WEST NORTH PROVIDE FRAMED OPENING FOR FUTURE OVERHEAD DOOR ~. ." 55- ~ ~ -- EXPOSED CMU END WALL . , ~ SOUTH ELEVATION SCALE: 1" - 30'-0" DD n I I I DD I . SITE PLAN SCALE: 1" - 40'-0" IJ.) ;...,¡ ::J ..¡....,¡ u IJ.) ..¡....,¡ .- ,...c; u ;...,¡ <: ( n , '---- -~'--'-- nDD I I PROJECT DATA: 22 EMPLOYEES 25 PARKING STALLS PROVIDED EXI~TING BUILDING { NEW ADDITION STEEL SIDING TO MATCH EXISTING ---1 I I I I I ) z 0 ~ ~ ~ ~ 0 ~ ~ ~ ~ rjJ 0 0 ~Z ~ ~tJj Z U ~Z 0 50 ~ o~ ~ 0 ~ u~ 0 ~ .... ~ f:JJ a "- ~~ 0 <I::CfJ ~ ~ ~o rjJ 0 ~ ~~ ~ ~~ ~ ~ ~CfJ 1.1")0 ~ ~ \0 Z 0 CfJ Z ~ ~ CfJ n nD I DATE 15 OCT 2004 PROJECT NUMBER 04-1037 PLOT DATE 10.07.2004 SHEET A1 ./ "".. j commerce.wLgov ~ i~~9Jl~JX! RECEIVED Safety and Buildings 2331 SAN LUIS PL STE 150 GREEN BAY WI 54304 TDD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov - / OCT ¿ '-) October 28, 2004 DI:PAR MENT OF COMMUNITY DEVELOPMENT Jim Doyle, Governor Cory L. Nettles, Secretary CUST ID No.903302 AITN: Buildings & Structures Inspector DUANE HELWIG MARTIN GANTHER GROUP 4825 COUNTY A OSHKOSH WI 54901 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 10/28/2006 _"lèIentÍÎicati Í1 NU1Ílòer~ Transaction ID No. 1069335 Site ID No. 690925 SITE: Swanson Wiper Corp 645 Leeward Ct W City of Oshkosh, 54901 Winnebago County FOR: Object Type: Building ICC Regulated Object ill No.: 986412 Major Occupancy: Storage; Type TIB Metal Frame Unprotected class of construction; Addition-Alteration plan; 10,000 project sq ft; Unsprinklered; Occupancy: Sot Storage Moderate-Hazard; Allowable area determined by: Fire Walls, Separated Use, Fire Barrier The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The pwner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Revised plans indicate a 4 Hr. area separation wall in the existing building. Per conversation "[ith Mr. Dean Glatting, a 3 Hr. Fire barrier wall between the existing building and addition will be provided as shown on the original submittal. Submit Comm 61.30(3) This review does not include heating, ventilating or air conditioning. The owner should be reminded that HV AC plans, calculations, and appropriate fees are required to be submitted for review and approval prior to installation. The submitted HV AC plans shall match the approved building plans. Submit, prior to installation, one (1) set of properly signed and sealed metal building plans, a completcd SB-118 application form including this transaction number and signed by the building designer, and $100 submittal fee to Safety & Buildings, P.O. Box 7162, Madison WI 53707-7162. . A copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authprized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plansets, a copy of this appro vat letter and index sheet shall be attached to plans that correspond with the"cppy on file with the Department All permits required by the state or the local municipality shall be obtained prior to commencement of cpnstructionlinstallationloperatipn. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility fpr designing a safe building, structure, or component Inquiries cpnceming this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. .¡ DUANE HELWIG Page 2 10/28/2004 Fee Required $ Fee Received $ Balance Due $ Jo J Wotruba P n Reviewer, Integrated Services (920)492-6500,7:45 am - 4:30PM j wotruba@comrnerce.state.wi.us 650.00 650.00 0.00 ~-.' ",~. . .'," cc: Peter R Ochs, Building Inspector, (920) 948-3500 ,Friday, 7:45 A.M. - 4:30 P.M. Swanson Wiper Corporation Buildings, HVAC, Compliance Statement This form is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical designer) observing construction of projects within buildings with total areas 50,000 c,ubic feet or greater and bleachers (Comm 50.10/Comm61.50). Failure to submit this form mayresuit in penalties as specified in Comm 50.26/Comm 61.23 and/or local ordinances. Generallnstructions: Prior to the initial occupancy of new buildings or additions and the final occupancy of altered existing buildings, submit this completed and signed form to: . The municipal building inspection office and . Safety and Buildings, 10541 N Ranch Road Hayward, Wi. 54843 Personal infonnation you provide may be used for secondary purposes [privacy Law, s. 15.04 (1)(m)]. 1. PROJECT INFORMATION: Please fill in the following with information from your plan approval letter. Transaction ID Number tOr.,Q.g35" Site Number f/1ð926 Site location (number & street) -1t'ls ~ ~7 JKf. City 0 Village 0 Townof ðJ;~SH County of \J~~o 2. PURPOSE OF THIS STATEMENT: (Check Box A, B, C, or D to indicate purpose and complete any other applicable boxes and information. Attach additional pages if necessary.) Check those which apply: }(Building Object iD # 18{' tl2. 0 HVAC Object ID # 0 Lighting Object ID # 0 Partial Completion' Description of Portion Completed A) )t. Statement of Substantial Compliance To the best of my knowtedge, belief, and based on onsite observation, construction of the following building andlorHVAC items applicable to this project have been completed in substantial compliance with the approved plans and specifications. [] BUILDINGILIGHTING ITEMS 1. Structural system Including submittal and erection of all building components (trusses, precast, metal buDä"g. etc.) 2. Fire protection systems (sprinklers, alanns, smoke detectors) designed, InstaRed, and tested Qncluding forward flow on baok flow devices) by appropriately registered professionals 3. Shaft and stairway enclosure 4. Exits Including exit and directionallighls 5. Are-<esIstive construction, enclosure of hazards, fire walls, labeled dooni, class of construction, fire stopped penetrations 6. Sanitation system (toilets, sinks, drinkIng facilities) 7. Ban1er.froelncluämg Comrn 18 elevators and lifts' 8. Energy envelope requirements 9. All conällions of buDding plan approval and applicable variances The following Items are not In compliance and must be addressed: 10. Exterior lighting & control requirements 11. Interior lighting & oontrol requirements 12. All conditions of Hghting plan approval and applicable variances [] HVAC ITEMS 1. HVACsyslem Including final test 2. All conättions of HVAC plan approval and applicable variances B) 0 Statement of Noncompliance Due to the following listed violations, this project Is not ready for occupancy: C) 0 Supervising Professional Withdrawn From Project (Use A or B above to indicate project status as of this date.) D) 0 Project Abandoned 3. SUPERVISING PROFESSIONAL SlaE ~ ~Building [] HVAC [] Lighting It:!. II(;¡ /'\ N e (p oše print or type) Phone number'j1A 1~ 'f17<tCu.stomer ID # qo:J 51J7... Date ~t1i -~ . ;{j SBD-9720 (R.OII2002) "" Building Permit Work Card Job Address 645-705LEEWARDCTWEST Permit Number 0111395 CreateDate 10/28/2004 OWner LEEWARD P80PERTIES LLC Category 210 - Addition. Industrial Contractor GANTHER CONSTRUCTION Type. Building Zoning 0 Sign 0 Canopy 0 Fence 0 Raze Plan N4-96-1004 Value $225,016.00 Garage ----.2 Sq. Ft. n Projection I Class of Const: 2Bibc Size 100x100 Unfinished/Basement 0 Sq. FinishediLiving 10000 Sq. Ft. -Ft. Rooms 0 Bedrooms 0 Baths 0 Stories 1 Height -----2 Ft. 0 Floating Slab 0 Post Canopies 0 Signs 0 Foundation. Poured Gencrete 0 Concrete Block 0 Pier 0 Treated Wood 0 Other Occupany Permit Required Flood Plain Height Permit # Structures Park Dedication # Dwelling Units ~ Use/Nature Factory/10,000 sf factory addition. . No work to commence above grade until parking lot drainage plans are of Work ~pproved by the City Engineering Division. HVAC Contr Plumbing Contr Electric Contr Inspections: Date 11/2/2004 -- Type Footings Inspector Allyn Dannhoff no time r-'"' DatelTime requested: Access: 11/212004 07:51 AM -- Notice Type: Phone Number: 920-731-5464 Ready Datemme: 11/212004 07:51 AM Requested By: Delrar-Laurie 0 Reinspect Fee 0 Fee Waived D Reinspect Fee Paid Date 11/3/2004 -- Type Footings Inspector Allyn Dannhoff no time r- ~ ._""""" Datemme requested: 11/3/2004 07:46 AM Access: Notice Type: Phone Number: 920-376-0229 Ready DatelTime: 11/3/2004 09:30 AM Requested By: GANTHER CONSTRUCTION-Paul 0 Reinspect Fee 0 Fee Waived D Reinspect Fee Paid Page 1 of3 Building Permit Work Card Job Address 645-705LEEWARDCTWEST Permit Number 0111395 CreateDate 10/28/2004 Owner LEEWARO PE!OPERTIES LLC Category 210 - Addition Industriai Contractor GANTHER CONSTRUCTION Type. Building Zoning 0 Sign 0 Canopy 0 Fence 0 Raze Class of Const: 2Bibc Size 1 00x1 00 Plan N4-96-1004 Value $225,016.00 Garage -----.2 Sq. Ft. n Projection I Unfinished/Basement 0 Sq. Finished/Living 10000 Sq. Ft. -Ft. Rooms --------.!! Bedrooms 0 Baths --------.!! Stories 1 Height --------.!! Ft. 0 Floating Slab 0 Post Canopies -----.2 Signs 0 Foundation. Poured Concrete 0 Concrete Block 0 Pier 0 Treated Wood 0 Other Occupany Permit Required Park Dedication Flood Plain Height Permit # Structures # Dwelling Units ~ Use/Nature Factory/10,000 slfactory addition. . No work to commence above grade until parking lot drainage plans are of Work þpproved by the City Engineering Division. HVAC Contr Plumbing Contr Electric Contr Inspections: Date 11/10/2004 ~ Type Footings Inspector Allyn Dannhoff no time REQUEST LINE 1 WOULD LIKE TO BACKFILL TOMORROW DatefTime requested: Access: 11/812004 08:04 AM -~ Notice Type: Phone Number: PAUL 376-0229 Ready DatefTime: 11/8/2004 08:04 AM Requested By: GANTHER CONSTRUCTION 0 Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Date 1/2812005 : PM -~ Type Final Inspector Allyn Dannhoff r'~' DatefTime requested: Access: -~ Notice Type: Phone Number: Ready DatefTime: ---'------ Requested By: 0 Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Page20f3 Building Permit Work Card Job Address 645-705LEEWARDCTWEST PennitNumber 0111395 CreateDate 10/28/2004 OWner LEE!^,ARD PJ30PERTIES LLC Category 210 - Addition industrial Contractor GANTHER CONSTRUCTION Type. Buiiding Zoning 0 Sign 0 Canopy 0 Fence 0 Raze Plan N4-96-1004 $225,016.00 Class of Const: 2Bibc Size 100x100 Value Unfinished/Basement 0 Sq. Finished/Living 10000 Sq. Ft. -Ft. Rooms 0 Bedrooms ~ Baths ~ Garage ~ Sq. Ft. n Projection I Height ~ Ft. 0 Floating Slab 0 Post Canopies ~ Signs 0 Stories 1 Foundation. Poured Concrete 0 Concrete Block 0 Pier 0 Treated Wood 0 Other Occupany Pennit Required Park Dedication Flood Plain Height Permit # Dwelling Units ~ # Structures Use/Nature Factory/10,000 sf factory addition. . No work toccmmence above grade untii parking lot drainage plans are of Work pproved by the City Engineering Division. HVAC Contr Plumbing Contr Electric Contr Inspections: Date 2/4/2005 -- Type Finai Inspector Aiiyn Dannhoff approved r~""~ DatelTime requested: Access: -- Notice Type: Phone Number: Ready DatelTime: -~ Requested By: 0 Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Date -- Type Note Inspector 12/22/05 REINSPECT WITH ADAM KRAUSE. EMERGENCY LIGHTiNG DONE -- Notice Type: Phone Number: DatelTime requested: Access: Ready DatelTime: -~ Requested By: 0 Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Page 3 of 3