Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0110733-Building (upgrade sprinklers)
No110733 CITY OF OSHKOSH OSHKOSHBUILDING PERMIT - APPLICATION AND RECORD ON THE WATER EVERGREEN MANOR INC Job Address1130 N WESTFIELD STOwnerCreate Date09/23/2004 DesignerContractorAHERN FIRE PROTECTION Category220 - Alteration Hospitals & InstitutionsPlan TypeBuildingSignCanopyFenceRaze ZoningClass of Const:Size Sq. Ft.Projection Unfinished/Basement0Rooms0Height0Ft. Finished/Living 0Sq. Ft.Bedrooms0StoriesCanopies0 Garage0Sq. Ft.Baths0Signs0 Poured ConcreteFloating SlabPierOther Foundation Concrete BlockPostTreated Wood Occupancy PermitNot RequiredFlood PlainNoHeight PermitNot Required Park DedicationNot Required# Dwelling Units0# Structures0 Evergreen Retirement Terrace II - Upgrade automatic sprinklers to quick response sprinklers as per plans submitted. Use/Nature of Work HVAC ContractorPlumbing Contractor Electric Contractor Fees: Valuation$15,000.00Plan Approval$0.00Permit Fee Paid$99.00Park Dedication$0.00 09/23/200400/00/0000 Issued By:DateFinal/O.P. Permit Voided Parcel Id #1608640000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. SignatureDate Agent/Owner 201 Morris CourtFond du LacWI549360000920-921-9020 Address-Telephone Number To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. O E N E R A L N 0 T E $ : .BLACK ~INWALL 40 LINES - Thinwall 40 Threaded Block Steel Pipe "SHOP CUT" To The Lengths Indicated On The Plan, Shop Threaded At Both Ends, Reld Joined With Block Cost Iron Screwed Body Fittings Unless Otherwise Noted. BLACK; UGHTWALL MAINS - Non-Threadable Lightwall Black Steel Pipe "SHOP CUT" To The Lengths Indicated On The Plan, Shop Roll Grooved At Both Ends, Shop Welded Outlets tf Applicable, Field Joined With Grooved Fittings And Couplings Unless Otherwise Noted. STD ~ HANGER NOTES - Pipe Hangers Shall Be Sized, Spaced, And Installed As Required By The NFPA J~15 Standards. No Other Piping And/Or Devices Are To Be Attached To The Sprinkler Hanging System Unless The Hanger Has Been Specifically Designed For The Additional Loading. This Contractor Does Not include The Material Or Devices To Improve The Structural Strength Of The Building To It To Carry The Load Of The Rre Protection System. See The CAD Details On This Sheet For Specific Hanger Assemblies Used For This Installation Project. ~GER SPACING per NFPA 13, t999 EDITION T~ble 6-2.2 Maximum Distance between Hangers (ft. - in.) Pipe Type Steel Pipe Except ~readed tightwall `3/4 1 1-1/,~ Nominal Pipe Size (in.) 1-1/2 2 2-1/2 3 `3-1/2 4 5 6 8 N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 t5-0 15-0 15-0 ~nreaded ~ghtwall N/A 12-0 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A N/A N/A Steel r'ipe Copper Tube 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 15-0 15-0 CPVC ~olybutylene tIPS) ~O~ybuUene (CTS) Ductile Iron Pipe 5-6 6-0 6-6 7-0 8-0 9-0 10-0 N/A N/A N/A N/A N/A N/A ,3-9 4-7 5-0 5-11 N/A N/A N/A N/A N/A N/A N/A 2-11 3-4- 3-11 4-5 5-5 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15-0 N/A 15-0 N/A 15-0 t5-0 ~te: IPS = Iron Pipe Size; CTS = Copper Tube Size JJ.~~.g~LJPANCIE~_: Light Hazard Occupancies Shall Be Occupancies Or Port;enD of Other Occupancies Where The Quantity And/Or Combustibility Of Contents Is Low And Fires With Relatively Low Rates Of Heat Releases Are Expected, ORD, ~AZARD OCCUPANCIES - Ordinary Hazard (Oroup 1) Occupancies Shall Be Occupancies Or Portions Of Other Occupancies Where Combustibility ts Low, Quantity Of Combustibles ts Moderate, Stockpiles Of Combustibles DO NOT Exceed 8 Ft. (2.4 m), And Fires With Moderate Rates Of Heat Release Are Expected. RiPE SYSTEM DESCRIPTION A Wet Pipe System ts A Fire Protection System Using Water Supplied From A Dependable Source As An Extinguishing Agent To Completely Fill The Piping System. Closed, Heat Sensitive, Automatic Sprinklers Spaced And Located In Accordance With Recognized Installation Standards Are Used To Detect A Fire. Upon Operation, The Sprinklers Distribute Water Over A Specific Area To Control Or Extinguish The Rre. As The Water Flows Through The System Piping, An Alarm Is Activated To Indicate That The System Is Operating. Sprinklers Immediately Over Or Adjacent To The Fire Operate - Minimizing Water Damage. W~_BIPE SYSTEM NO~$ - The System Is Designed and Installed In Accordance With NFPA 13 - t999 Standards And All Local Codes. Light Hazard Occupancy Areas Are Designed To Provide A Density of .10 GPM For The Most Remote 1500 Sq Ft And Include 100 GPM Hose Allowance. Section 7-2.`3.2.4 Of NFPA 1`3 - 1999 Allows The Reduction Of The Area Of Operation Without Reducing The Density When Quick-Response Type Sprinklers Are Used Throughout A System OR A Portion Of A System HovinQ The Same Hydraulic Design Basis When All Of The Following Conditions Are Satisfied: Wet Pipe System. . Light Hazard Or Ordinary Hazard Occupancy. 20-R (6.1 m) Maximum Ceiling Height. SEE Figure 7-2.,3.2.4. & Area Reduction CALCULATIONS On This Sheet. Ordinary Hazard Group 1 Occupancy Areas Are Designed To Provide A Density of .15 GPM For The Most Remote 1500 Sq Ft And Include 250 GPM Hose Allowance. Section 7-2.3.2.4 Of NFPA 13 -1999 Also Applies to Reduce The Area. Ordinary Hazard Group 2 Occupancy Areas Are Designed To Provide A Density of .20 GPM For The Most Remote 1500 Sq Ft And Include 250 GPM Hose Allowance. Section 7-2.3.2.4 Of NFPA 13 -1999 Also Applies to Reduce The Area. Alt Materials And Devices Essential To The System Operation Are To Be UL Listed and/or FM Approved. A Total of 6 Spare Sprinklers (In Cabinet With Head Wrench) will Be Provided In Accordance With NFPA I3, Section 3-2.9 All Control, Drain, And Test Connection Valves To Be Provided with The Proper Identification Per NFPA t3, Section 3-8.3 Auxiliary Drain Valves Are To Be Sized & Located At The Low Points Of All Trapped Sections Of Pipe Per Section 5-14.2.5 The Owner ts Responsible For Providing Adequate Heat (Maintained At Or Above 40' F) Throughout The Entire Area Protected By A Wet Pipe System. Sprinkler Heads Shown Are Not Necessarily Located In The Centedine Of Ceiling Tiles. Painting Of Pipe And Fittings (If Required) Is To Be Performed By Others Unless Specified tn The Contract, SMALL ROOM RULES The Following 1~ From NFPA J15 - t999 And. Shall Be Used As Spacing Ouidel. bes For Ali Rooms Less Thon ~ua!. TO 800 Sq. Ft. 5-6_~2.1 Exception. Within Small Rooms As Defined tn 1-4.2, Sprinklers Shall Be Permitted To Be Located Not More Than 9 Ft. (2.7m) From Any Single 'Wall. Sprinkler Spacing Limitations Of 5-6.3 And Area Limitations Of Table 5-6,2.2(a) Shall Not Be Exceeded. A-5~6.3.2.1 Exception. An Example Of Sprinklers tn Small Rooms For Hydraulically ;Designed And Pipe Schedules Is Shown In Figure A-5-6.3.2.1(b), And ;Examples For Hydraulically Designed Systems Only Are Shown In Figures A-5-6.3.2.1(c), (d), And (e). 16'-6" Rgure A-5-6.&2.1(b) Small Room Provision - One Sprinkler. 30'-0' 0 7'-6" 15'-0" 0 Figure A-5-6.3.2.1(c) Small Room Provision - Two Sprinklers Centered Between Sidewalls Rgure A-5-6,3.2.1(d) Small Room Provision - Two Sprinklers Centered Between Top Md Bottom Wails 0 0 0 6LO~ o t_ Figure A-5-6.3.2.1(e) Small Room Provision - Four Sprinklers R£VIsIoNS - SEE CLouDED / FLAGGED AREAs DATE BY' DEScRIPTIoN OF cHANGES G -- Gt~)O~ (I~N~i.L ~ ~T mO0~) P -- ~ (CUT PIPE - NO END PREP) sm lo- ~. ~o ~w~ ~ .... 1/8" = 1'-0", - 0 2 4 8 SYSTEM DESIGN DATA ELEVATBR E)dSTING STAIR 2¸4 'SUPPLY FROM FIRST FLOOR +7-I BATH BEDRBt~t t BEDRDDM 1 BEDROOM BEDR00N hl BEDROOM __ +7-6 +7-6 BATH +7-6 BATH BATH +7-6 +7-3 +7% +7-6 DE.DOM BEDROOM BEDROOH BEDROOM +7-3 BEDROOM +7-6 -" +7-3 +7-6 l I+ e'-7' I BEDROOM i BEDROOM SIDEWALL SPRINKLER HEAD--~...~ ~ W/ EXTENDED ESC. LIGHT FIXTURE~ ~'~'-- WALL SIDEWALL DETAIL NO SCALE BEDROOM BEBRDOM ~DROFiM BEDROOM Lt. BEDRO~ BEDRDO~ I+ e,7~t ,, 32 FEET HAZARD CLAssiRCATION: TOTAL S~TEW AREA: HYD. DE,~ DATA - DENSITY: GPM/SQ FT SQ FT/HD AREA OF APPucATION: SC) FT SYsTEM REQuIREMENTs: GPM I) PSI AT: WATER SUPPLY INFoRMATIoN - sTATIc PREssURE: PSI RESIDUAL PREssuRE: PSI TOT~ FLOW AVAILABLE: GPM ELEvATIoN: FT TEST LOcATIoN: BY: TEST DATE: APPRovALS REQUIRED: R NE~TES: R E S I D E N T I A L, M ~ AS 9ASHE]}, NEW EXISTING SYSTEM NER IS MAKING SLIGHT R NE3VATIBNS lB ALL SPRINKLERS lB ©U!CK I P ~ P IN 6 R H A I N I N 5 A S- ~ S B A T H R [i] [3 X RESPBN~r ',_25 ~}ES;ENE} P R PIPE SOHE}ULE N E %/ H'Y D B A U k lC C A k C U k A l; [3N S, LJ~'x FITTE~ N[3TES: - 1' PTPE AND FITTINGS F1VERS 18 SPRINKLER - ANY UNUSED PIPIN6 I INCLUDED HEA]}S AS FITTER 113 1Fl CE]HPLY B~ BP, DFR C~RRECT NIPPLE WITH ]]FTAIL SHFtWN BN TN CHANGE NEEDED, CAPPED LENGTH T / PLUGED, F[3R SIDEWALL HIS SHEET, THIS DRAWING PROPERTY OF AHERN FIRE PROTECTION COP~IGHT © 2004- &F. AHERN CO. REPRoDUCTIoNS tN ANY FORM ~OLA~S COP~IGHT A U TOM ATI C Ft R E S P Rt N K LER D ESi GN B AS ED ON THE FOLLo~NG NFPA sTANDARDs F1 NFPA 13 --2003 Fl NFPA 13 D --1999 ~ NFPA 13 R --1999 Fl NFPA 14 2000 r-I NFPA 20 --1999 ~ EXIs~NG WAKE / MODEL ~N;D~ ~K1NG VK300 ~KING ~302 ~KING ~440 ~KING ~430 SPRINKLERS RESPONSE TYPE TYPE UPRIGHT QR PENDENT QR HSW REsIDENTIAL PENDENT RESIDENTIAL THREAD SIZE 1/2" I/2" t/2" 1/2" NOM. 5.¸6 4,3 4.3 MAX. COvERAGE 2:25 225 14'x 14' 20' x 20' CALC'D j DEFLECT. COVERAGE t DIsTANcE N.A. I. ~'- ~2:' N.A. il"- t 3/4' N,A. 1'- 1 3/4' TEMP. RNISH i55 CHR~E 155 ~ITE 155 ~ITE 155 ~iTE ESC. ~ENCH 10'896W/B S~'B. 0 QUANTITY N.A. 6 E-1 10896W/B e 44 NATL 88 10896W~ 40 E-1 12144W/B ¸6O TOTAL SPRINKLERs ON THIS sHEET: 150 CLIEN T: I !PR°TECTIoN)I° ~ l~ LIC. NO. j PROJECT 'MANAGER: VAN FITCH SINCE 1,880 A h e r n F i r e P rote ct i o n A division of.1. F, Ahern Co. 201 Morris court / P.O, Box 1516 Fond du Lac, WI 549,36-1316 TEL: (920)921-9020 FAX: (920)921-8666 WEB: www.ohernfire,com E ~ R GR E EN TE R R A C E 1130 N. ~STFIELD sTREET DESIGNER'S STAMP SCALE: 1/8" = 1'-0" DRAWN BY: T. JULKA tEXT#5429) CHECKED BY: DAVE DEwHuRsT DATE: 9-13-04 :FILE NO: 490256 CoNTRAcT NO: 490256 sHEET qTLE: CoNTRAcT ~TH: AUToMATIc SPRINKLER SYSTEM PLAN DAN BINDER CONsTRUcTIoN CoNTAcT: TOM BINDER (920) 231-2114 1224 W. SOUTH PARK AVE. OSHKosH, Wi 54901 :sHEET NO. FP-1 of REVISION NO: /~